E-mail
896509498@qq.com
-
Phone
15081660683
-
Address
Liuyanma Industrial Zone, Dacheng County, Langfang City, Hebei Province
Tianjin Cable Factory Rubber Cable Factory
896509498@qq.com
15081660683
Liuyanma Industrial Zone, Dacheng County, Langfang City, Hebei Province
MCPcableMCPCoal mining machine cableMCPMining rubber sheathed flexible cableMCPMining electricityApplication fields:Mainly used in the field of geology and mining,Especially in coal mines,Provide power and signal transmission for equipment such as coal mining machines.
Cable specifications:The specific specifications are3core70mm²、1core25mm²and4core6mm²The combination,This configuration can meet the high-power requirements and complex electrical systems of coal mining machines.
Safety standards:The cable meets the requirements of the safety mark certificate issued by the Mining Product Safety Mark Center,Ensure safe use in high-risk environments such as mining sites.
Cable characteristics:
The rated voltage is0.66/1.14KV,Voltage requirements applicable to mining environments such as coal mines.
The long-term allowable operating temperature of the conductor is65℃,Adapt to the high temperature environment of the mining site.
The bending radius of a cable is equal to the diameter of the wire6Double,Ensure that the cable maintains good electrical performance even when bent.
type number core number Nominal cross-section(mm2)
MC—0.38/0.66 3+1 16~185
MCP—0.38/0.66 3+1 16~185
MCP—0.66/1.14 3+1 35~185MCP 1.9/3.3 3 * 150+1 * 70+6 * 6 rubber sheathed flexible cable
MCP—0.66/1.14 3+3/3 50~185
MCP—1.9/3.3 3+1 35~185MCP 1.9/3.3 3 * 150+1 * 70+6 * 6 rubber sheathed flexible cable
MCP—1.9/3.3 3+3/3 35~185
Requirements and standards for the production of mining cables:

1Insulation resistance between main cores of cable insulation and between main cores and ground wire,Convert to+20Not less than at ℃100MΩ·km.
2Product standards:GB818.2-1999.
3TheMCType cable,have3The main wire core, one ground wire core, and a set of control units consist of2Core,3Core,4Core and7After the cable is formed, a black chlorinated polyethylene rubber sheath or a black chloroprene rubber sheath is extruded on the outside.
4Conductive wire core: Made of tin plated soft copper wire, its performance meets the requirementsGB/T3956-1997.
5Insulation: AdoptingGB7594.2-1987ChineseXJ-00.Type rubber.
6Core identification: Insulation color separation identification is used, with the main core being red, green, and white. The ground wire is black, and the control wire is numbered.
7Cable formation: Twist in the right direction to form a cable. Central filling core without control unit. Place the ground wire in the center if there is a control unit.
8Sheath: AdoptingGB7594.7-1987ChineseXH-03.Type rubber.
9TheMCThe flame retardant performance of the finished cable meets the requirements ofMT386-1995The requirements.