Manufacturer of composite chlorine dioxide generator
Composite chlorine dioxide generatorAs a manufacturer, we have chosen Xiangyi Yuansheng, an 11 year old manufacturing enterprise, to provide chlorine dioxide generator equipment for more than 6000 water plants and sewage treatment plants in Hubei, Hunan, Guangxi, Guizhou, Yunnan, Sichuan, Guangdong, Xinjiang, Inner Mongolia, Liaoning, Zhejiang and other provinces and cities. Our products are exported to countries and regions such as Myanmar, Vietnam, Indonesia, and Africa. We are a key recommended brand for national water system product bidding and a trustworthy enterprise brand in Changsha. Below is a brief introduction to the product features of Xiangyi Yuansheng Chlorine Dioxide Generator:
technical requirement
1) Chlorine dioxide disinfectant generator
The chlorine dioxide production of the generator should not be lower than the rated value;
The mass percentage of chlorine dioxide (calculated as effective chlorine) in the disinfectant solution generated by the generator shall not be less than 95% of the total effective chlorine;
The conversion rate of main raw materials such as sodium chlorite is not less than 80%.
2) Chlorine dioxide composite disinfectant generator
The effective chlorine production of the generator should not be lower than the rated value;
The mass percentage of chlorine dioxide (calculated as effective chlorine) in the disinfectant solution generated by the generator shall not be less than 55% of the total effective chlorine;
The conversion rate of main raw materials such as sodium chlorate and sodium chlorite is not less than 60%.
3) Under normal operating conditions, the service life of the generator is not less than 5 years, and the average time between failures is not less than 8000 hours.
4) The generator should have good sealing under normal operating conditions. When the generator is used indoors (with good ventilation conditions and an ambient temperature of 5 ℃ to 40 ℃), the concentration in the indoor environment should comply with the provisions of HJ/T 30, and the high allowable concentration should be less than 1mg/m.
5) When used for drinking water, the total amount of residual raw materials such as chlorite and chlorate in disinfected water should not exceed 0.7mg/L.

Chlorine dioxide generator manufacturer
Control requirement editing
The control system can automatically adjust the dosage of medication according to changes in water quality, and is equipped with various safety protection facilities such as water shortage shutdown and no medication shutdown. The chlorine dioxide generator, under the control of an electromagnetic flowmeter, is fully automatic with constant proportional dosing, achieving fully automatic unmanned control and remote data transmission. It has a remote communication interface that can communicate with DCS computers.