The ozone sensor is based on three electrode electrochemical measurement of ozone (O3) content in water, with an built-in NTC sensor for automatic temperature compensation and a reference electrode to ensure the stability and stability of the measurement results. The sensor is made of sanitary grade pollution-free materials and is suitable for fields such as water treatment plants, secondary water supply, pipe network terminals, medical disinfection, swimming pools, industrial water circulation, and wastewater treatment plant effluent disinfection. The product has RS485 communication interface and standard MODBUS protocol, which facilitates integration and networking. Comes with WQS-SUTIE analysis software, which can perform functions such as parameter setting, calibration, measurement, and fault diagnosis on the product.
1ozonesensorIntroduction
ozone sensorBased on the composite ion selective electrode for measuring total chlorine (including free chlorine and bound chlorine) in water, it meets the EPA330.1 standard. The sensor adopts a solid-state electrode structure with strong anti-interference ability, no need to replace the electrolyte, and simple and convenient cleaning and maintenance. The sensor is made of hygienic and pollution-free materials, suitable for fields such as water treatment plants, secondary water supply, pipe network terminals, medical disinfection, swimming pools, and industrial water circulation. The product has RS485 communication interface and standard MODBUS protocol, which facilitates integration and networking. Comes with WQS-SUTIE analysis software, which can perform functions such as parameter setting, calibration, measurement, and fault diagnosis on the product.
2、 Product Features
Three electrode system, stable and reliable measurement results
Built in NTC sensor for automatic temperature compensation
Real time measurement of reaction current with short response time
The turbidity or chromaticity of the water sample does not affect the measurement results
The DPD method is used for calibration at the factory, and the factory calibration parameters can be restored at any time
3、 Product parameters
range |
0-2mg/L |
precision |
±0.05mg/L |
temperature range |
0-50℃; |
PH range |
6-10pH |
Response time (T90) |
≤ 30 seconds |
temperature range |
0-50℃; |
interface |
RS-485, MODBUS protocol |
Working Voltage |
7-36VDC |
Protection level |
IP68 |
material |
PVC |
size |
240mmL*30mmD |
weight |
350g |