1、 Product Overview
Wood products, furniture, flooring, carpets, footwear products, building decoration materials, automotive interiors, and other products that come into contact with the human body will emitVOCSubstances such as volatile organic compounds (VOCs) and formaldehyde that are harmful to human health, especially in densely packed and enclosed indoor spaces such as cars, have higher cumulative concentrations and pose greater health hazards.
The test chamber provides a clean enclosed space without liquid water, while controlling the temperature, humidity, wind speed, relative pressure, and air exchange rate inside the chamber to simulate the pollutant release process of the product in a specific environment.
2、 Technical parameters
|
serial number |
project |
Performance Specifications |
|
|
1 |
Volume size |
Studio Capacity |
1000L±20L |
|
2 |
studio |
850×1080×1100mm(Width x Depth x Height) |
|
|
3 |
appearance |
1580×1285×1572mm(Width x Depth x Height) |
|
|
4 |
Gate (doorway) |
850×1100mm(Width x Height) |
|
|
5 |
observation window |
225×365mm(Width x Height) |
|
|
6 |
temperature |
temperature range |
10~40℃ (customized for high temperature) |
|
7 |
temperature fluctuation |
≤ ±0.5 ℃ |
|
|
8 |
Temperature Uniformity |
≤±0.8 ℃ |
|
|
9 |
Temperature resolution |
0.1 ℃ |
|
|
10 |
temperature control |
Air suite connection temperature control method (external heating and cooling components) |
|
|
11 |
humidity |
humidity range |
30~80 % RH |
|
12 |
Humidity fluctuations |
≤ ±1% RH |
|
|
13 |
Humidity uniformity |
≤ ±2 % RH |
|
|
14 |
Humidity resolution |
0.1 % RH |
|
|
15 |
humidity control |
Dry moisture ratio control method (external), stable time ≤40 min |
|
|
16 |
purification system |
Precision particle filtration component |
Using polytetrafluoroethylene film(PTFE)Filter element, high material cleanliness, no pollution to the filter medium, filtration accuracy MIN is0.1um |
|
17 |
Membrane filtration module |
Adopting ultrafiltration membrane with a pore size range of0.001-0.02Micro porous filtration membrane. Can screen out molecules smaller than the pore size to separate molecules with a molecular weight greater than500Dalton (atomic mass unit), particle size greater than10Nano particles |
|
|
18 |
Adsorption filtration component |
By alternately stacking and filling adsorbents treated with both polarized and non polarized agents, both polar and non-polar molecules in volatile organic compounds can be adsorbed and removed, ensuring that the background concentration of fresh air is close to zero. At the same time, a large redundancy design is adopted to reduce the frequency of filter material replacement and improve the ability to resist environmental pollution impact |
|
|
19 |
Ventilation and sealing |
Air exchange rate |
0.2~2.5time/hour |
|
20 |
Center wind speed (adjustable) |
0.1~1.0 m/s |
|
|
21 |
sealing performance |
plus1000PaOverpressure, gas leakage less than1×10-3m3/min |
|
|
22 |
Equipment recycling rate |
>85 % |
|
|
23 |
Relative positive pressure maintenance |
10±5 Pa |
|
|
24 |
material |
Cabin material |
SUS304Mirror-finished stainless steel1.5mmRounded corners, fully welded and polished |
|
25 |
Shell material |
Q235Acold-rolled steel sheet1.5mmSurface electrostatic spraying, white |
|
|
26 |
Sealing material |
Imported polytetrafluoroethylene and fluororubber |
|
|
27 |
thermal insulation material |
80 mmHigh density polyurethane foam |
|
|
28 |
Operation and monitoring |
human-machine interface |
Delta7Inch color touch screen |
|
29 |
Equipment control mode |
The following control methods can be implemented: ① Local control: Operate the device directly on the touch screen ② Regional control: View and control devices on any LAN computer ③ Remote control: the device can be accessed and controlled anywhere via the Internet |
|
|
Automatically record projects |
Automatically record the following items in the workspace: ① temperature ② humidity ③ pressure ④ traffic ⑤ runtime ⑥ system alarm It can achieve functions such as system control, program settings, dynamic data display and historical data playback, fault recording, alarm settings, etc |
||
|
30 |
safety protection |
System protection |
① High temperature protection inside the cabin ② Power overload, leakage, phase loss, undervoltage, overvoltage, phase sequence protection ③ Refrigeration system high and low pressure protection, overload protection ④ Overheating protection for heating components ⑤ Motor overcurrent protection ⑥ Fan and air pump overheat and overload protection ⑦ Humidification and water shortage protection ⑧ pressure protection |
|
31 |
interface |
data interface |
The device provides the following external interfaces: ①USB A:1a ②USB B:1a ③RJ-45:1a ④RS232:1a |
|
Sampling interface |
3A (Φ)8mm) |
||
|
32 |
other |
noise |
≤60 dB |
|
33 |
cover an area of |
1.7×2.8 m(Width x Depth, including door opening and surrounding heat dissipation space) |
|
|
34 |
power supply |
AC220V 3KW |
|
|
35 |
Humidification water |
distilled water |
|
|
36 |
Water replenishment cycle |