PZ973H electric knife type gate valve, electrically driven, clamp type connection, rising stem parallel rigid single gate valve, Z973F valve seat sealing surface material is fluoroplastic, Z973H valve seat sealing surface material is stainless steel, nominal pressure PN6-16, valve body material is carbon steel gate valve.
Product Details

Electric knife type gate valvePZ973H/F/Y/X

Product Description

PZ973H electric knife type gate valveElectric drive, clamp type connection, open rod parallel rigid single gate,Z973F valve seat sealing surface material is fluoroplastic, Z973H valve seat sealing surface material is stainless steel, nominal pressure PN6-16, valve body material is carbon steel gate valve.

Equipped with a multi turn electric device, the valve plate can move in a straight line up and down, and can be remotely controlled to open or close the valve. Diameter range:DN50~DN500, The operating temperature is ≤ 100 ℃, widely used in drainage, heating, power plants, chemical, food, papermaking, pharmaceuticals, coal, mining and other engineering projects.

Product performance parameters

Main performance parameters of Z973F and Z973H electric knife gate valves (knife gate valves)

model

PN

work pressure/ MPa

Applicable Temperature/ ℃

Applicable Medium

Z973F-6C

6

0.6

≤ 100

Ash residue, etc

Z973H-6C

Z973F-10C

10

1.0

Z973H-10C

Z973F-16C

16

1.6

Z973H-16C

Product component materials

Z973F, Z973H electric knife gate valve (knife gate valve) component materials

model

material

valve body

ram

sealing surface

valve stem

filler

Z973F-6C

carbon steel

Chromium nickel titanium stainless steel

fluoroplastic

Chromium stainless steel

asbestos

Z973H-6C

Inlaid or spray welded iron-based alloys

Z973F-10C

fluoroplastic

Z973H-10C

Inlaid or spray welded iron-based alloys

Z973F-16C

fluoroplastic

Z973H-16C

Inlaid or spray welded iron-based alloys

Product appearance and structural dimensions (PN6)

Z973F, Z973H (PN6) electric knife gate valve (knife gate valve) appearance and structural dimensions (mm)

DN

L

D1

D2

z×ød

H

DENSO model number

weight/ kg

50

50

90

110

4x12

370

DZ10

52

65

50

110

130

4x12

460

DZ10

53

80

50

125

150

4x16

590

DZ10

55

100

50

145

170

4x16

780

DZ10

57

150

60

200

225

eight by 16

980

DZ10

71

200

60

255

280

eight by 16

1053

DZ15

81

250

70

310

335

12x116

1060

DZ20

100

300

80

362

395

12x120

1230

DZ20

123

350

90

412

445

12x120

1250

DZ30

148

400

100

462

498

16x120

1770

DZ30

158

450

120

518

550

16x120

1920

DZ45

225

500

130

568

600

16x120

2010

DZ45

240

Installation and commissioning method of electric gate valve:

1. Electric gate valves can be installed on horizontal or vertical pipelines. Single and double gate gate valves should be installed on horizontal pipelines, and the handwheel should be located above the valve, and downward installation is not allowed. The flow direction of the medium in the gate valve is not restricted.

2. 2. Electric gate valves are usually connected by flanges, and welding connections are also used in special occasions.

3. For large-diameter and high-pressure gate valves, the opening and closing torque is relatively large. To reduce the opening and closing torque, a bypass valve can be installed. The bypass valve is installed outside the main gate valve, and its inlet and outlet are connected in parallel with both sides of the main gate valve. Before opening the main gate valve, the bypass valve should be opened first. After entering the valve, the pressure difference before and after the gate of the main gate valve should be reduced, thereby reducing the opening torque of the main gate valve. The selection of bypass valve diameter should be based on the main valve diameter and usage requirements.

4. 4. Electric gate valves are block valves with inferior sealing performance compared to globe valves. The main 'responsibility' of a gate valve is to 'cut off flow' and 'continue flow' with minimal resistance. It is not suitable for regulating the flow rate and pressure of the medium. If used for a long time, the sealing surface is easily eroded and worn by the medium, which affects the sealing performance.

5. 5. Attention should be paid to the reliability of the use of electric gate valves in terms of medium temperature and pressure. At high temperatures and pressures, changes in temperature may cause the gate to become stuck, and uneven temperature distribution of the medium can lead to unsealing. Wedge type but gate valve is particularly obvious.

6. 6. When powering on for the first time, attention should be paid to the phase sequence of the power supply. The correct operation method is to manually open the gate valve to the * * position, and then jog the switch valve to adjust the stroke of the valve (contact the manufacturer for specific adjustment methods) before it can operate normally.