Welcome Customer !

Membership

Help

Jiangsu Shuci Measurement and Control Equipment Co., Ltd
Custom manufacturer

Main Products:

hbzhan>Products

Jiangsu Shuci Measurement and Control Equipment Co., Ltd

  • E-mail

    mkt0@sigas-group.com

  • Phone

    17751172369

  • Address

    Building 15-16, Binjiang Science and Technology Innovation Center, No. 59 Jiangnan Avenue, Economic Development Zone, Changshu City

Contact Now

Photoacoustic trace gas analyzer

NegotiableUpdate on 02/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The photoacoustic trace gas analyzer displays the detection concentration curve in real-time, with fully automatic or manual zero calibration, allowing customers to freely choose. High detection accuracy and good stability, suitable for various trace gas concentration detection scenarios.
Product Details

Schulz SPTr GAS ® The ANALYZER photoacoustic trace gas analyzer is equipped with a touch display control screen, a reasonable menu structure distribution, and an intuitive and friendly operating interface. All status displays, threshold values, and alarm values are provided in analog and digital formats. Real time display of detection concentration curve, fully automatic or manual zero calibration, freely chosen by customers. High detection accuracy and good stability, suitable for various trace gas concentration detection scenarios.

Photoacoustic spectroscopy is a new spectroscopic technology based on the photoacoustic effect, which is different from traditional infrared spectroscopy technology. It effectively converts light signals into sound signals and calculates the final gas concentration through the detection of sound signals by precision microphones. Due to the special optical structure of photoacoustic spectroscopy technology and the special calculation process in signal acquisition and processing, this method can efficiently collect weak photoacoustic signals and effectively eliminate the interference of background signals. It is very suitable for trace gas concentration detection and interference free detection in complex environments.

Photoacoustic trace gas analyzerApplication direction:

▪ Industrial online monitoring (semiconductor, power, chemical, metallurgical, etc.)

▪ Environmental pollution detection

▪ On site inspection and troubleshooting

▪ Exhaust gas detection

▪ Gas process control

▪ Air pollution detection

▪ TOC detection in water

▪ Blast furnace gas detection

▪ Garbage incineration and landfill

▪ Tunnel gas detection

technical indicators

Product Model

SPTr-GAS® ANALYZER

Detection Principle

Photoacoustic spectroscopy

Display Zuilowvalue

0.1 ppm (typical), Different according to the detection range

response time

Cycle time<20s

Detection limit

<0.01% FS varies depending on the detection range

warm-up time

When the ambient temperature is 20 ° C (68 ° F), it takes approximately 15 minutes to heat up to 50 ° C (122 ° F);

Operation method

Touch screen, 5.6 "LCD

analog output

4mA~20mA (during normal operation)

2mA (during preheating or status alarm)

Analog output range

Default settings: The lower range corresponds to 4mA, and the upper range corresponds to 20mA, which can be adjusted by the user

Alarm contact output

6-way output

The following signals can be allocated through the relay output allocation function:

X1 device malfunction error alarm

Sample gas sampling control solenoid valve control signal during x1 automatic calibration

X1 automatic calibration zero point gas control solenoid valve control signal

XN channels (N is the number of channels) automatic calibration range gas control solenoid valve control signal z

XN channels (N is the number of channels) for measuring gas concentration upper/lower limit alarm

Relay contact capacity

1A contact (250V AC/2A, resistive load)

communication

Serial port output RS232 (DB-9 female head)

RS485 modbus

Working Voltage

198~242V AC, 50/60 Hz power<125W

power interface

EN60320 C1

fuse

Fuse current 3A, fast melting fuse size: 5mm x 20mm

Shell protection level

IP41 (EN60529)

weight

Unpackaged about 10kg with packaging about 19kg

intake flow

(0.2~1.2) L/min (flow fluctuation should be ≤ 0.02 L/min) Note: The instrument flow rate for photoacoustic spectroscopy detection principle type is (1.5~2.0) L/min

intake air temperature

(5~35)℃

intake pressure

116 kPa (maximum)

Moisture in gas

• Non condensing

• Dew point of intake: 5 ℃± 0.1 ℃ (this is necessary when the measurement channel includes SO2 and/or NO)

Particulate matter in gas

100µg/m³, ≤1µm

Zero point calibration gas

99.999% N2 (nitrogen)

Third point calibration gas (midpoint)

0.375~0.625 of the full range of the measured gas

Full range calibration gas (user calibration)

0.75~1.25 of the full range of the measured gas

Gas detection range category:

gas

Detection range

linear error

precision

Background gas

NH3

Ammonia

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

NH3

Ammonia

0…1 g/m3

0.1% FS

0.1% FS

Air or N2

C5H10

Cyclopentane

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C3H6O

Acetone

0…2000ppm

0.1% FS

0.1% FS

Air or N2

C2H6O

Ethyl Alcohol

0…2000ppm

0.1% FS

0.1% FS

Air or N2

C3H8O

Isopropyl Alcohol

0…1000ppm

0.1% FS

0.1% FS

Air or N2

CH4O

Methyl Alcohol

0…500ppm

0.1% FS

0.1% FS

Air or N2

NF3

Cyclopentane

0…20ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

N2O

Nitrous Oxide

0…500ppm

0.1% FS

0.1% FS

Air or N2

C2Cl4

PERC

0…800ppm

0.1% FS

0.1% FS

Air or N2

SO2F2

ProFume®

0…1 g/m3

0…1000ppm

1…150 g/m3

0.1% FS

0.1% FS

Air or N2

CCl3F

R11

0…500ppm

0.1% FS

0.1% FS

Air or N2

C2Cl3F3

R113

0…50ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2F6

R116

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CCl2F2

R12

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2HCl3F2

R122

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2HCl2F3

R123

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CClF3

R13

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CF4

R14

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CHClF2

R22

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CHF3

R23

0…150ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C8H8

Styrene

0…50ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

SO2

Sulfur dioxide

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

SO2

Sulfur dioxide

0…1000ppm

0.1% FS

0.1% FS

SF6

C8H20O4Si

TEOS

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2HCl3F2

Toluene

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2HCl3

TRI

0…1000ppm

0.1% FS

0.1% FS

Air or N2

CH3Br

Methyl Bromide

0…2 g/m3

0.1% FS

0.1% FS

N2 (only)