Pneumatic carbon steel regulating valve
| Pneumatic carbon steel regulating valve |
|
Structural optimality: equal cross-section low flow resistance channel, large rated flow coefficient |
Valve body parameters |
Good adjustable type: large adjustable range, flow characteristics can be selected as equal percentage or linear |
Nominal pressure PN16, PN25, PN40, PN64 |
Good sealing performance: can choose soft seal or corrugated pipe seal to improve sealing performance |
Connection method: flange type, (special: welding type) |
Widely used: various valve seat structures, heat sinks, suitable for different pressure differentials and temperatures |
Valve body materials WCB, SS304, SS316, SS316L |
|
Valve core materials: SS, SS304, SS316, SS316L, and Steyr welding |
Technical Parameter |
Sealing material PTFE, hard seal, special high-temperature material |
Action mode: air open, air closed |
Bellows SS, SS304, SS316 |
Valve seat structure P single seat |
Packing PTFE, flexible graphite |
Percentage and linearity of traffic characteristics |
Push rod 2Cr13 |
Adjustable range 50:1 |
Gasket rubber asbestos board, 1Cr18Ni9Ti asbestos wrapped gasket |
Signal range Pr: 0.2~1bar, 0.4~2bar |
Flange standards GB9113-88, JB/T79-94, GB2555-81 |
Gas source pressure Ps: 1.4 bar~4 bar |
|
Sealing grade III, IV, V, VI |
Function attachment options |
Environmental temperature -30 ℃~+70 ℃ (see locator parameters for explosion-proof type) |
E - Explosion proof type (electrical locator explosion-proof level optional: explosion-proof type, intrinsic safety type) |
Basic error ± 2.5% |
X - with signal feedback (electrical locator with feedback or equipped with valve position transmitter) |
Input signal 4~20mA DC, 0~10V DC |
S - with handwheel mechanism |
Output signal 4~20mA DC, 0~10V DC |
Q - Fully Cut off Type |
Explosion proof grade dIIBT4/T5/T6, dIICT4/T5/T6, intrinsic safety type |
Attachment: Electrical locator, air filter pressure reducer, air lock valve, solenoid valve |
|
Specifications and technical parameters |
Nominal diameter DN (mm) |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
10 |
12 |
15 |
20 |
Rated flow coefficient Kv |
straight line |
1.5 |
2.8 |
4.4 |
6.9 |
11 |
17.6 |
27.5 |
44 |
69 |
110 |
176 |
275 |
440 |
690 |
Equal percentage |
1.6 |
2.5 |
4.0 |
6.3 |
10 |
16 |
25 |
40 |
63 |
100 |
160 |
250 |
400 |
630 |
Rated process L (mm) |
16 |
25 |
40 |
60 |
Membrane limited area Ae (cm2) |
280 |
400 |
600 |
1000 |
Allowable leakage amount |
Hard seat: IV (rated capacity of 10-4 valve) Soft seat: Class VI |
Working temperature t |
Normal temperature type |
-20 ℃~200 ℃, -40 ℃~250 ℃, -60 ℃~250 ℃ |
Heat dissipation |
-40 ℃~450 ℃, -60 ℃~450 ℃ |
High temperature type |
450℃~560℃ |
Low temperature type |
-60 ℃~-100 ℃, -100 ℃~-200 ℃, -200 ℃~-250 ℃ |
|
Allowable differential pressure pneumatic control valve, allowable differential pressure gauge unit: MPa |
Effective area of membrane Ae (cm2) |
280 |
400 |
600 |
1000 |
Signal range Pr (kPa) |
20-100 |
20-100 |
40-200 |
20-100 |
20-100 |
40-200 |
20-100 |
20-100 |
4-200 |
20-100 |
20-100 |
40-200 |
Gas source pressure Ps (MPa) |
0.14 |
0.14 |
0.25 |
0.14 |
0.14 |
0.25 |
0.14 |
0.14 |
0.25 |
0.14 |
0.14 |
0.25 |
Accessories required |
- |
P |
P |
- |
P |
P |
- |
P |
P |
- |
P |
P |
state-owned call open up or clear out by poking or jabbing footpath DN(mm) reach valve seat straight Diameter d (mm) |
20 |
10 |
5.35 |
6.40 |
6.40 |
|
|
|
|
|
|
|
|
|
12 |
3.72 |
6.40 |
6.40 |
|
|
|
|
|
|
|
|
|
15 |
2.33 |
5.55 |
6.40 |
|
|
|
|
|
|
|
|
|
20 |
1.34 |
3.12 |
4.01 |
|
|
|
|
|
|
|
|
|
25 |
25 |
0.86 |
2.00 |
2.57 |
|
|
|
|
|
|
|
|
|
32 |
32 |
|
|
|
0.75 |
1.74 |
2.24 |
|
|
|
|
|
|
40 |
25 |
|
|
|
1.22 |
2.85 |
3.67 |
|
|
|
|
|
|
32 |
|
|
|
0.75 |
1.74 |
2.24 |
|
|
|
|
|
|
40 |
|
|
|
0.48 |
1.11 |
1.48 |
|
|
|
|
|
|
50 |
32 |
|
|
|
0.75 |
1.74 |
2.24 |
|
|
|
|
|
|
40 |
|
|
|
0.48 |
1.11 |
1.48 |
|
|
|
|
|
|
50 |
|
|
|
0.31 |
0.71 |
0.91 |
|
|
|
|
|
|
65 |
65 |
|
|
|
|
|
|
0.27 |
0.63 |
0.81 |
|
|
|
80 |
50 |
|
|
|
|
|
|
0.46 |
1.07 |
1.38 |
|
|
|
65 |
|
|
|
|
|
|
0.27 |
0.63 |
0.81 |
|
|
|
80 |
|
|
|
|
|
|
0.18 |
0.42 |
0.52 |
|
|
|
100 |
65 |
|
|
|
|
|
|
0.27 |
0.63 |
0.81 |
|
|
|
80 |
|
|
|
|
|
|
0.18 |
0.42 |
0.52 |
|
|
|
100 |
|
|
|
|
|
|
0.11 |
0.26 |
0.34 |
|
|
|
125 |
125 |
|
|
|
|
|
|
|
|
|
0.12 |
0.29 |
0.37 |
150 |
100 |
|
|
|
|
|
|
|
|
|
0.19 |
0.44 |
0.57 |
125 |
|
|
|
|
|
|
|
|
|
0.12 |
0.29 |
0.37 |
150 |
|
|
|
|
|
|
|
|
|
0.09 |
0.20 |
0.25 |
200 |
125 |
|
|
|
|
|
|
|
|
|
0.12 |
0.29 |
0.37 |
150 |
|
|
|
|
|
|
|
|
|
0.09 |
0.20 |
0.25 |
200 |
|
|
|
|
|
|
|
|
|
0.05 |
0.11 |
0.14 |
|
Allowable differential pressure pneumatic open control valve, allowable differential pressure gauge unit: MPa |
Effective area of membrane Ae (cm2) |
280 |
400 |
600 |
1000 |
Signal range Pr (kPa) |
20-100 |
40-200 |
20-100 |
40-200 |
20-100 |
4-200 |
20-100 |
40-200 |
Gas source pressure Ps (MPa) |
0.14 |
0.25 |
0.14 |
0.25 |
0.14 |
0.25 |
0.14 |
0.25 |
Accessories required |
- |
P |
- |
P |
- |
P |
- |
P |
state-owned call open up or clear out by poking or jabbing footpath DN(mm) reach valve seat straight footpath d(mm) |
20 |
10 |
5.35 |
6.40 |
|
|
|
|
|
|
12 |
3.72 |
6.40 |
|
|
|
|
|
|
15 |
2.38 |
5.55 |
|
|
|
|
|
|
20 |
1.34 |
3.12 |
|
|
|
|
|
|
25 |
25 |
0.86 |
2.00 |
|
|
|
|
|
|
32 |
32 |
|
|
0.75 |
1.74 |
|
|
|
|
40 |
25 |
|
|
1.22 |
2.85 |
|
|
|
|
32 |
|
|
0.75 |
1.74 |
|
|
|
|
40 |
|
|
0.48 |
1.11 |
|
|
|
|
50 |
32 |
|
|
0.75 |
1.74 |
|
|
|
|
40 |
|
|
0.48 |
1.11 |
|
|
|
|
50 |
|
|
0.31 |
0.71 |
|
|
|
|
65 |
65 |
|
|
|
|
0.27 |
0.63 |
|
|
80 |
50 |
|
|
|
|
0.46 |
1.07 |
|
|
65 |
|
|
|
|
0.27 |
0.63 |
|
|
80 |
|
|
|
|
0.18 |
0.42 |
|
|
100 |
65 |
|
|
|
|
0.27 |
0.63 |
|
|
80 |
|
|
|
|
0.18 |
0.42 |
|
|
100 |
|
|
|
|
0.11 |
0.23 |
|
|
125 |
125 |
|
|
|
|
|
|
0.12 |
0.28 |
150 |
100 |
|
|
|
|
|
|
0.19 |
0.44 |
125 |
|
|
|
|
|
|
0.12 |
0.26 |
150 |
|
|
|
|
|
|
0.09 |
0.20 |
200 |
125 |
|
|
|
|
|
|
0.12 |
0.28 |
125 |
|
|
|
|
|
|
0.09 |
0.20 |
200 |
|
|
|
|
|
|
0.05 |
0.11 |
*P:POSITIONER |
*regardingLDZJH(P)Single seat bellows sealed regulating valve,The maximum allowable pressure difference is1.0MPaIf the values in the table are less than1.0MPaIf the value is greater than, it remains unchanged |
1.0MPa, then take the value1.0MPa. |
|
Standard type, heat dissipation type, high temperature type external dimensions Unit: mm |
Nominal Diameter |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
ΦA |
282 |
308 |
394 |
498 |
L |
PN16,40 |
150 |
160 |
180 |
200 |
230 |
290 |
310 |
350 |
400 |
480 |
600 |
PN64 |
230 |
230 |
260 |
260 |
300 |
340 |
380 |
430 |
500 |
550 |
650 |
H1 |
PN16 |
53 |
58 |
70 |
75 |
83 |
93 |
100 |
110 |
125 |
143 |
170 |
PN40 |
53 |
58 |
70 |
75 |
83 |
93 |
100 |
118 |
135 |
150 |
188 |
PN64 |
65 |
70 |
78 |
85 |
90 |
103 |
108 |
125 |
148 |
173 |
208 |
H |
treetop accurate type |
PN16 |
429 |
438 |
474 |
476 |
502 |
622 |
642 |
687 |
835 |
889 |
981 |
PN40 |
429 |
438 |
474 |
476 |
502 |
622 |
646 |
695 |
845 |
896 |
1000 |
PN64 |
456 |
468 |
511 |
525 |
535 |
663 |
673 |
705 |
868 |
958 |
1260 |
High temperature heat dissipation type |
570 |
570 |
610 |
610 |
630 |
730 |
810 |
820 |
960 |
1090 |
1180 |
|
Outline dimension table of corrugated pipe sealing type Unit: mm |
Nominal Diameter |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
ΦA |
282 |
308 |
394 |
498 |
L |
150 |
160 |
180 |
200 |
230 |
290 |
310 |
350 |
400 |
480 |
600 |
H1 |
53 |
58 |
70 |
75 |
83 |
93 |
100 |
110 |
125 |
143 |
170 |
H standard type |
446.5 |
453.5 |
490 |
542 |
537.5 |
617.5 |
667 |
675 |
735 |
907.5 |
900 |
|
Low temperature type external dimension table Unit: mm |
Nominal Diameter |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
ΦA |
282 |
308 |
394 |
498 |
L |
PN16,PN40 |
150 |
160 |
180 |
200 |
230 |
290 |
310 |
350 |
400 |
480 |
600 |
|
PN64 |
230 |
230 |
260 |
260 |
300 |
340 |
380 |
430 |
500 |
550 |
650 |
H1 |
PN16,40 |
52.5 |
57.5 |
70 |
75 |
82.5 |
92.5 |
100 |
117.5 |
135 |
150 |
187.5 |
|
PN64 |
65 |
70 |
77.5 |
85 |
90 |
102.5 |
107.5 |
125 |
147.5 |
172.5 |
207.5 |
H2 |
-60℃~-100℃ |
500 |
500 |
500 |
500 |
500 |
600 |
600 |
600 |
700 |
700 |
700 |
-100℃~-200℃ |
700 |
700 |
700 |
700 |
700 |
800 |
800 |
800 |
900 |
900 |
900 |
-200℃~-250℃ |
900 |
900 |
900 |
900 |
900 |
1000 |
1000 |
1000 |
1100 |
1100 |
1100 |
H |
-60~-100℃ |
PN16,40 |
810 |
810 |
832 |
832 |
832 |
1026 |
1026 |
1024 |
1200 |
1198 |
1198 |
PN64 |
810 |
810 |
832 |
832 |
832 |
1026 |
1026 |
1024 |
1200 |
1198 |
1198 |
-100~-200℃ |
PN16,40 |
1010 |
1010 |
1032 |
1032 |
1032 |
1226 |
1226 |
1124 |
1400 |
1398 |
1398 |
PN64 |
1010 |
1010 |
1032 |
1032 |
1032 |
1226 |
1226 |
1124 |
1400 |
1398 |
1398 |
-200~-250℃ |
PN16,40 |
1210 |
1210 |
1232 |
1232 |
1232 |
1426 |
1426 |
1424 |
1600 |
1598 |
1598 |
PN64 |
1210 |
1210 |
1232 |
1232 |
1232 |
1426 |
1426 |
1424 |
1600 |
1598 |
1598 |
ΦD3 |
260 |
260 |
285 |
305 |
340 |
370 |
405 |
460 |
525 |
590 |
700 |
ΦD4 |
290 |
290 |
315 |
335 |
370 |
400 |
435 |
490 |
555 |
630 |
740 |
Bolt holes n (pieces) - d (diameter) |
8-14 |
8-14 |
8-14 |
8-16 |
8-16 |
10-16 |
10-16 |
12-18 |
14-18 |
16-18 |
18-18 |
|
Weight table of regulating valve Unit: kg |
Nominal Diameter |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
Standard type |
PN16 |
16 |
17 |
19 |
21 |
23 |
35 |
48 |
57 |
64 |
70 |
90 |
PN40 |
16 |
17 |
19 |
21 |
23 |
35 |
48 |
60 |
67 |
74 |
95 |
PN64 |
20 |
21 |
25 |
30 |
33 |
44 |
71 |
91 |
100 |
115 |
145 |
High temperature heat dissipation type |
17 |
18 |
20 |
22 |
25 |
36 |
51 |
60 |
67 |
74 |
95 |
Bellows sealed type |
20 |
21 |
25 |
30 |
33 |
48 |
71 |
91 |
102 |
115 |
145 |
Low temperature type |
20 |
21 |
23 |
26 |
28 |
42 |
58 |
69 |
77 |
84 |
108 |
remarks: |
*The weight of the high-temperature heat dissipation type in this table isPN16Based on this, the low-temperature type isPN40As a basis. |
*Flange sealing surface form:PN10、PN16For convex surfaces,PN40、PN64For concave and convex surfaces, the valve body is concave |
*Thin film actuator gas signal interface: internal threadM16*1.5 |
*Jacket insulation type jacket heat carrier interface: butt weldingΦ18*4 |
*The distance between the valve body flange and the flange end face can be manufactured according to the standard specified by the user. |
|