Welcome Customer !

Membership

Help

Jiangsu Shuci Measurement and Control Equipment Co., Ltd
Custom manufacturer

Main Products:

hbzhan>Products

Jiangsu Shuci Measurement and Control Equipment Co., Ltd

  • E-mail

    mkt0@sigas-group.com

  • Phone

    17751172369

  • Address

    Building 15-16, Binjiang Science and Technology Innovation Center, No. 59 Jiangnan Avenue, Economic Development Zone, Changshu City

Contact Now

Portable photoacoustic spectroscopy trace detection

NegotiableUpdate on 02/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The special optical structure of photoacoustic spectroscopy and the special calculation process in signal acquisition and processing enable this method to efficiently collect weak photoacoustic signals and effectively eliminate background signal interference. It is very suitable for trace gas concentration detection and interference free detection in complex environments.
Product Details

Schulz SPTr GAS ® Tracer isPortable photoacoustic spectroscopy trace gas analyzerIntegrate all functional modules into a 1/2 19 "chassis, equipped with a touch display control screen, a reasonably distributed menu structure, and an intuitive and friendly operating interface. All status displays, threshold values, and alarm values are provided in analog and digital form. Real time display of detection concentration curves, fully automatic or manual zero calibration, can be freely selected by customers. The detection accuracy is high, the stability is good, and it is suitable for various trace gas concentration detection occasions.

Photoacoustic spectroscopy is a new spectroscopic technology based on the photoacoustic effect, which is different from traditional infrared spectroscopy technology. It effectively converts light signals into sound signals and calculates the final gas concentration through the detection of sound signals by precision microphones. Due to the special optical structure of photoacoustic spectroscopy technology and the special calculation process in signal acquisition and processing, this method can efficiently collect weak photoacoustic signals and effectively eliminate the interference of background signals. It is very suitable for trace gas concentration detection and interference free detection in complex environments.

Portable photoacoustic spectroscopy trace detectionApplication direction:

▪ Industrial online monitoring (semiconductor, power, chemical, metallurgical, etc.)

▪ Environmental pollution detection

▪ On site inspection and troubleshooting

▪ Exhaust gas detection

▪ Gas process control

▪ Air pollution detection

▪ TOC detection in water

▪ Blast furnace gas detection

▪ Garbage incineration and landfill

▪ Tunnel gas detection

Advantages of portable photoacoustic spectroscopy trace detection products

Effectively shielding against humidity interference in the detection environment: The infrared humidity detection module is directly configured inside the photoacoustic module.

Shielding interference caused by unstable temperature: The photoacoustic spectrum is heated to 50 degrees and maintained at this temperature for detection.

Shielding other gas interference: By detecting weak photoacoustic signals, amplifying and calculating gas concentration through precise signal amplification

Internally integrated air pump and three automatic control valves for sampling points

Analyzer configuration internal activated carbon filter

Install replaceable dust filters on sampling tubes near each detection point

According to different types of gases, the zero point can be automatically calibrated with air

technical indicators

Product Model

SPTr-GAS®300 Tracer

通道

Refer to the analyzer nameplate or factory inspection report for channel configuration.
The channel configuration information includes:

-Measure gas type

-Measurement range

-Measurement error

response time

Cycle time:<20s

warm-up time

Approximately 30 minutes (depending on different detector configurations)

resolution

Usually: 0.1 g/m3 varies depending on the detection range

Operation method

Touch screen, 5.6 "LCD

analog output

4mA~20mA (during normal operation)

2mA (during preheating or status alarm)

Allow load resistance

250Ω~350Ω

Alarm contact output

Equipment status alarm

Measurement channel upper/lower limit alarm

Note:

When the measured value is greater than the upper limit alarm value or less than the lower limit alarm value, the relay will close due to electric shock.

All relays are isolated from each other and from internal circuits.

Relay characteristics

1A contact (250V AC/2A, resistive load)

communication

Serial port output RS232 (7-pin connector blue/black cable)

Working Voltage

(198~242)V AC, 50/60 Hz

power interface

EN60320 C1

fuse

Rated current: 3A, Blow characteristic: Fast Acting

Size: 5mm x 20mm

Shell protection level

IP42 (EN60529)

weight

约15 Kg (typical)

Gas detection range category:

gas

Detection range

linear error

precision

Background gas

NH3

Ammonia

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

NH3

Ammonia

0…1 g/m3

0.1% FS

0.1% FS

Air or N2

C5H10

Cyclopentane

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C3H6O

Acetone

0…2000ppm

0.1% FS

0.1% FS

Air or N2

C2H6O

Ethyl Alcohol

0…2000ppm

0.1% FS

0.1% FS

Air or N2

C3H8O

Isopropyl Alcohol

0…1000ppm

0.1% FS

0.1% FS

Air or N2

CH4O

Methyl Alcohol

0…500ppm

0.1% FS

0.1% FS

Air or N2

NF3

Cyclopentane

0…20ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

N2O

Nitrous Oxide

0…500ppm

0.1% FS

0.1% FS

Air or N2

C2Cl4

PERC

0…800ppm

0.1% FS

0.1% FS

Air or N2

SO2F2

ProFume®

0…1 g/m3

0…1000ppm

1…150 g/m3

0.1% FS

0.1% FS

Air or N2

CCl3F

R11

0…500ppm

0.1% FS

0.1% FS

Air or N2

C2Cl3F3

R113

0…50ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2F6

R116

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CCl2F2

R12

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2HCl3F2

R122

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2HCl2F3

R123

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CClF3

R13

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CF4

R14

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CHClF2

R22

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

CHF3

R23

0…150ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C8H8

Styrene

0…50ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

SO2

Sulfur dioxide

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

SO2

Sulfur dioxide

0…1000ppm

0.1% FS

0.1% FS

SF6

C8H20O4Si

TEOS

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2HCl3F2

Toluene

0…100ppm

0.5ppm / 0.1% FS

0.1ppm / 0.1% FS

Air or N2

C2HCl3

TRI

0…1000ppm

0.1% FS

0.1% FS

Air or N2

CH3Br

Methyl Bromide

0…2 g/m3

0.1% FS

0.1% FS

N2 (only)

For other gas please contact us for more information.