Overview
Hospitals and other medical institutions generate a certain amount of medical wastewater during their operations, which generally contains pathogenic microorganisms, toxic and harmful physical and chemical pollutants, and has characteristics such as space pollution, acute transmission, and latent transmission. If not effectively treated, it will become a pathway for disease spread and seriously pollute the environment
Product Details
Prices of hospital sewage treatment equipment manufacturers
Hospitals and other medical institutions generate a certain amount of medical wastewater during their operations. The water generally contains pathogenic microorganisms, toxic and harmful physical and chemical pollutants, and has characteristics such as spatial pollution, acute infection, and latent infection. If not effectively treated, it can become a pathway for disease spread and seriously pollute the environment.
Based on the protection of the surrounding environment and in accordance with the requirements of the local environmental management department, our company has developed a new type of medical wastewater treatment equipment for hospital medical wastewater treatment based on years of technical reserves and extensive on-site research, providing one-stop solutions to various medical wastewater problems.
Structural characteristics and working principle, equipment installation, use and operation
医院污水处理设备厂家设备特点



Characteristics of hospital sewage treatment equipment manufacturers:
1. Buried below the surface, the surface above the equipment can be used for greening or other purposes, without the need for building houses, heating, or insulation.
2. The secondary biological contact oxidation treatment process adopts push flow biological contact oxidation, which has a better treatment effect than fully mixed or two-stage series fully mixed biological contact oxidation tanks. And it has a smaller volume than activated sludge tanks, strong adaptability to water quality, good shock load resistance, stable effluent quality, and will not cause sludge expansion. A new type of composite three-dimensional packing material is used in the pool, with a large specific surface area and easy biofilm formation and detachment by microorganisms. Under the same organic load conditions, the removal rate of organic matter is high and the energy consumption is low.
3. The biochemical tank adopts the biological contact oxidation method, which has a relatively low volume load of the filling material, and the microorganisms are in their own oxidation stage, resulting in low sludge production. It only takes more than three months (90 days) to discharge the sludge (using fecal trucks to suction or dehydrate into sludge cakes for external transportation).
4. The deodorization method of this buried medical sewage treatment equipment not only uses conventional high-altitude exhaust, but also includes soil deodorization measures.
5. The entire equipment processing system is equipped with a fully automatic electrical control system and equipment fault alarm system, which operates safely and reliably. Generally, there is no need for dedicated personnel to manage it, only timely maintenance and upkeep of the equipment is required.
Working principle of hospital sewage treatment equipment manufacturers:
Due to the high concentration of suspended solids, pathogenic microorganisms, and other pollutants in hospital medical wastewater, it is necessary to use physical and chemical processes to remove these pollutants as much as possible in the early stages. Otherwise, it will affect the operation and management effectiveness of the entire processing system. Therefore, this plan proposes to install a grille before the sewage enters the biochemical treatment system to remove suspended solids in the water.
Due to the low CODCr content and good biochemical effect of sewage, in order to reduce investment, lower operating costs, and enhance the system's ability to withstand impact loads, this plan adopts the "anaerobic+aerobic" treatment method for sewage biochemical treatment.
Medical wastewater is first treated through a grid groove to remove suspended solids and other impurities in the water, preventing blockages in subsequent treatment processes and causing blockages in waterways, which can affect system operation. The sewage filtered by the grid flows automatically into the regulating tank, which is a structure for regulating and homogenizing the sewage volume. Due to the uneven discharge of sewage during the day and night, and the large coefficient of variation over time, the regulating tank is designed for regulating the sewage volume. To ensure the balanced operation of the subsequent treatment system and minimize the impact of sewage shock load, in order to achieve the desired treatment effect, it is necessary to set up a regulating tank to adjust and homogenize the sewage volume, so that the regulating tank lift pump always supplies water to the subsequent treatment system according to the average treatment volume. Data statistics show that the effective volume of the regulating tank is calculated based on 6-10 times the average hourly treatment capacity. Two sewage lifting pumps are installed at the end of the pool to lift water to the integrated sewage treatment equipment, one in use and one as backup. The operation of the lift pump is controlled by the liquid level float. When the water level in the regulating pool is at a high level, the water pump automatically starts; When the liquid level is low, the water pump automatically stops.
The effluent from the regulating tank flows automatically into the high-efficiency anaerobic tank. Anaerobic hydrolysis acidification biological treatment of sewage is a treatment method that uses the degradation effect of anaerobic microorganisms to purify organic matter in sewage under anaerobic or hypoxic conditions. Under anaerobic conditions, anaerobic bacteria in wastewater decompose organic compounds such as carbohydrates, proteins, and fats into organic acids. Then, under the action of methane bacteria, they further ferment to form methane, carbon dioxide, and hydrogen, thereby purifying the wastewater. After hydrolysis and acidification treatment, the difficult to degrade organic compounds in water can be converted into easily degradable organic compounds in small molecules, thereby improving the treatment efficiency of subsequent aerobic treatment units. The use of hydrolysis acidification process can greatly shorten the time required for aerobic biochemistry; After simultaneous treatment, the effluent quality is better, which not only saves investment and operating costs, but also improves environmental benefits.
The effluent from the anaerobic tank flows automatically into the new contact oxidation unit. Biological packing is a combination of packing materials on a fixed bed. Using fillers as attachment carriers for microorganisms. The organisms are evenly distributed on the biological packing, which avoids the phenomenon of uneven distribution of microorganisms. At the same time, the organisms adhere to the surface of the packing and do not flow with water. Due to the strong agitation of the rising airflow, the biofilm is constantly renewed, thereby improving the purification effect. The high-efficiency infiltration filter method has the advantages of short treatment time, small volume, good purification effect, good and stable effluent quality, no need for sludge reflux or expansion, and low power consumption.
医院污水处理设备厂家特点主要有



The main characteristics of hospital sewage treatment equipment manufacturers are:
(1) High volumetric load and strong resistance to impact load;
(2) Having the advantages of membrane method, with less residual sludge;
(3) It has the advantages of activated sludge process, supplemented by mechanical equipment for oxygen supply, high biological activity, and short sludge age;
(4) Can decompose substances that are difficult to decompose by other biological treatments;
(5) Easy to manage, eliminating drawbacks such as sludge flotation and expansion.
The wastewater treated by the contact oxidation unit is discharged after passing through the sedimentation tank and disinfection tank to meet the standards.
Hospital sewage treatment equipment manufacturer equipment usage:
1. Capable of treating comprehensive wastewater from the medical system and similar organic wastewater;
2. It is made of glass fiber reinforced plastic, stainless steel and carbon steel, and has excellent characteristics of corrosion resistance and aging resistance, with a service life of more than 15 years;
3. The complete set of equipment is simple to construct and easy to operate. All mechanical equipment is automatically controlled, and all devices can be installed below the surface.


Price List of Hospital Sewage Treatment Equipment:

医院污水处理设备价格表