Overview
The XHFC-3A pump suction dust detector uses a laser as the light source for light scattering rapid dust measurement. The measurement principle is that when light is irradiated on suspended particles in the air, scattered light is generated. Under certain particle properties, the scattered light intensity of particles is proportional to their mass concentration. By measuring the scattered light intensity and applying the mass concentration K value, the mass concentration of particles can be obtained. The instrument is a new type of dust measuring instrument that can simultaneously monitor TSP, PM10, PM2.5, and has functions such as temperature and humidity compensation and automatic calibration. It can effectively reduce the impact of low temperature and humidity on measurement values, improve measurement accuracy in high humidity climate environments, and continuously monitor particulate matter in the air online.
Product Details
Product Introduction
The XHFC-3A pump suction dust detector uses a laser as the light source for light scattering rapid dust measurement. The measurement principle is that when light is irradiated on suspended particles in the air, scattered light is generated. Under certain particle properties, the scattered light intensity of particles is proportional to their mass concentration. By measuring the scattered light intensity and applying the mass concentration K value, the mass concentration of particles can be obtained. The instrument is a new type of dust measuring instrument that can simultaneously monitor TSP, PM10, PM2.5, and has functions such as temperature and humidity compensation and automatic calibration. It can effectively reduce the impact of low temperature and humidity on measurement values, improve measurement accuracy in high humidity climate environments, and continuously monitor particulate matter in the air online.
This instrument has the functions of dust sampling inlet and outlet, filter barrel device, and can protect the service life of the vacuum pump, improving the overall service life of the instrument. It can be continuously monitored in high temperature environments and can work stably and reliably in high temperature environments at installation sites. Capable of working continuously for 7x24 hours, with functions such as fault self inspection and automatic restart.
Basic Parameters
Brand: Xinghua Environmental Protection Model: XHFC-3A type
Power supply method: DC 8V-30V(max.100mV ripple) Working method: Can be adjusted according to demand
Output method: UART+RS232 or UART+RS485 (Modbus) service life: >35000 hours at 50 ℃ (continuous use for more than 3 years)
Monitoring principle: Principle of Laser Scattering power waste: 2W
Monitoring parameters
monitoring indicators measurement range resolution accuracy repeatability error zero drift
PM2.5 0.1-2000ug/m3 0.1ug/m3 ±10% ±10% ±10%FS
PM10 0.1-10000ug/m3 0.1ug/m3 ±10% ±10% ±10%FS
TSP 0.1-10mg/m3 or 30mg/m3 0.1mg/m3 ±10% ±10% ±10%FS
Our company can provide support for handling CPA and CCEP
Product Features
1. Accurate data: laser principle detection, industrial grade photoelectric induction;
2. Adopting pump suction sampling monitoring, the performance is stable, the service life is long, the data is accurate, the sensitivity is high, the error is small, and the consistency is good. It is equipped with a powerful German imported suction pump, which has fast response time, strong anti-interference ability, and is more suitable for sampling places that require longer sampling tubes.
3. Resolution: 0.1ug/m3 particle size, 0.001mg/m ³; Detect PM2.5, PM10, TSP;
4. Stable performance: able to adapt to different atmospheric dust composition, with independent parameter coefficient adjustment;
5. Data transmission: RS485 (Modbus standard protocol) or RS232, UART output; Provide switch output and can be connected to outdoor sound and light alarm devices, etc
6. Intelligent monitoring: Real time monitoring of various indicators of sensors, and timely feedback to users when abnormal states occur;
7. It can be customized separately according to customer requirements. [Short customization cycle]
Product features
1. The default sensor runs automatically after being powered on, and data is passively uploaded. The sensor works for 30 seconds and stops for 30 seconds (default 30 seconds, which can be selected through commands). This cycle is repeated;
2. The sensor also provides three other working modes, which can be switched through commands
3. If the sensor malfunctions, the status indicator light and buzzer will sound an alarm
Note: The optimal working state is to work for 30 seconds and stop for 30 seconds
Application field
1. Construction site dust detection system
2. Atmospheric environment detection system
3. New air intelligent control system
4. Intelligent Building Weak Current Control System
execution standard
Outline for Evaluation of Dust Concentration Measuring Instrument Forms (JJF 1716-2018)
Environmental Air Quality Standards GB3095-2012
Metrological Verification Regulations - Light Scattering Digital Dust Tester JJG846
Method for determination of inhalable particulate matter (PM10) in the air of public places - light scattering method "WS/T206
Comprehensive Emission Standards for Air Pollutants GB16297
Technical Requirements and Detection Methods for Continuous Automatic Monitoring System of Environmental Air Particulate Matter (PM10 and PM2.5) HJ 653
Computer Information System Security GA 216.1-1999
Computer Software Development Specification GB8566-88
GB5748-85 "Determination of Dust in Workplace Air"
Determination of concentration by atmospheric dust method GB6921-86
Technical Requirements and Experimental Methods for Insulation Resistance and Insulation Strength of Industrial Automation Instruments GB/T15479-1995
Implementation Rules for Environmental Product Certification - Micro Environmental Air Quality Monitoring System CCAEPI-RG-Y-040-2017