Qingdao Feed Factory Exhaust Gas Odor Purification Renovation
Qingdao Feed Factory Exhaust Gas Odor Purification Renovation
The original feed factory has environmental protection equipment, which has been inspected and renovated by various parties. Equipment and parameters for deodorization and purification of waste gas in feed factories
Exhaust gas purification treatment equipment: JF-FC20000 ultraviolet cold combustion deodorization equipment
Quantity: 1 set
Workshop exhaust fan: Use the factory's existing fan.
Exhaust gas emission pipeline: Use the factory's existing pipeline.
To achieve optimal purification effect, a reaction time of 3-5 seconds is required, and the length of the rear air duct of the JF-FC ultraviolet cold combustion deodorization equipment needs to be more than 20 meters.
Delivery deadline for odor removal equipment for waste gas treatment in feed factories: Sign the contract and deliver the equipment to the installation site within 15 working days.
When selecting treatment equipment, it is necessary to optimize the combination of odor treatment schemes for feed mill drying, forming an efficient, cost-effective, and low-energy consumption treatment process. Purification effect and safety guarantee of waste gas treatment in feed factories: The ultraviolet cold combustion deodorization equipment provided in this scheme ensures that there is no obvious odor at a distance of 5 meters from the exhaust outlet, and meets the emission standards, namely the second level standard of the Comprehensive Emission Standard of Air Pollutants (GB16297-1996) and the second level standard of the Odor Pollutant Emission Standard (GB14554-93).
Design basis for waste gas treatment scheme in feed mill:
(1) Environmental Protection Law of the People's Republic of China;
(2) Comprehensive Emission Standards for Air Pollutants (GB16297-1996);
(3) Emission Standards for Odor Pollutants (GB14554-1993);
(4) Environmental Air Quality Standards (GB3095-1996);
(5) GB12348-12349-90 "Standard and Measurement Method for Boundary Noise in Factories and Enterprises";
(6) Occupational Exposure Limits for Hazardous Factors in the Workplace (GBZ 2-2002);
(7) Hygiene Standards for Industrial Enterprise Design (GBZ 1-2002);
(8) Regulations on Environmental Protection Management of Construction Projects, State Council Decree No. 253 of the People's Republic of China, 1998