Rotary aerator fan

NegotiableUpdate on 03/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The HC series rotary aerator produced by our factory contains Japanese technology and has the characteristics of small size, large air volume, low noise, low energy consumption, stable operation, easy installation, minimal faults, and long service life. The product is widely used in: water
Product Details

The HC series rotary aerator produced by our factory contains Japanese technology and hasSmall size, high air volume, low noise, low energy consumption, smooth operation, easy installation, minimal malfunctions, long lifespanSuch characteristics.
The product is widely used in:Water treatment blast aeration, sewage mixing aeration in hospitals and laboratories, vacuum paper feeding in the printing industry, electroplating cabinets, mixing aeration for industrial wastewater, plasticGas supply for welding and blowing, spray for burner, glass industry, central air conditioning spray and others.

This modelRotary fanInstallation, please refer to the general mechanical equipment installation specifications. In addition, the following items should be noted:

1 During installation, use a spirit level to calibrate the level, and use secondary grouting method for the foot screw mouth.
2 When installing, first check the body to confirm that there are no debris, then close the intake and exhaust ports, thoroughly remove rust and other debris from the pipes, and then connect to the fan. It is required that there is no air leakage at each interface.
3 A pressure gauge should be installed on the exhaust pipe to reflect the outlet pressure of the rotary fan. In order to prevent overloading and damage to the components, a safety check valve must be installed on the exhaust pipe.
4 In order to ensure the safe operation of the rotary fan, the fan is not allowed to bear external loads such as pipes, valves, cabinets, etc. The secondary load must be supported by a means.
5 Install current and voltage meters in the circuit control system to observe the working status of the fan.


undefined

1 The temperature of the imported gas shall not exceed 40 ℃.
2 The bearing temperature shall not exceed 95 ℃.
3 The temperature of the lubricating oil should not exceed 65 ℃.
4 The rotation direction of the electric motor is consistent with the standard rotation direction of the fan.
5 Inject engine oil into the fuel tank until the oil level line is reached. Lubricating oil varies with seasonal temperature changes. It is recommended to use N32 lubricating oil in summer and N10 lubricating oil in winter.
6 The blower is running at no load
1】 Newly installed or overhauled fans must operate at no load.
2】 The concept of no-load operation is to put it into operation with all inlet and outlet valves open.
3】 During the trial operation, pay attention to observing that the oil nozzles at both ends of the lubricating oil are normal. If there is too much or too little, adjust the ink (15-20 points per minute).
4】 There is no abnormal odor, smoking phenomenon, or collision friction sound.
5】 Run under no-load for about 20 minutes, the situation is normal, and it can be put into operation with load. If any abnormality is found, it should be checked and after troubleshooting, it still needs to go through no-load operation.
6】 During normal operation of the fan, it is strictly prohibited to completely close the exhaust valve or operate it at overload.
The safe operation and service life of rotary fans depend on proper and regular maintenance, and attention should be paid to any potential faults.

DSCF077.jpg

Technical parameters of rotary aerator fan

model

exhaust
caliber
(mm)

motor
power
(kw)

frequency
(HC-S)

fan
speed
(rpm)

Airflow (m3/min)

V-belt pulley

V-shaped
belt
Fuel tank storage
fuel level
(Effective fuel quantity)

Weight (kg)

0.1kgf
/cm2

0.2kgf
/cm2

0.3kgf
/cm2

0.4kgf
/cm2

0.5kgf
/cm2

blower motor

net weight

hair volume

HC-120S

3/4'(20)

0.25

50 450 0.12 0.115 0.110 0.105 0.100

6”

11/2'

A-40

2.0L(1.5L)

35

38

HC-150S

3/4'(20)

0.25

50

580

0.156

0.150

0.145

0.140

0.138

6”

2'

A-40

2.0L(1.5L)

35

38

HC-200S

3/4'(20)

0.37

50

680

0.210

0.205

0.200 0.195 0.190 6' 2'

A-40

2.0L(1.5L)

38

41

HC-251S

3/4'(20) 0.55 50

450

0.31 0.30

0.29

0.28

0.28

8'

21/2'

A-40

1.5L(1.1L)

44

51

HC-30S

1'(25)

0.55 50 430

0.35

0.34

0.33

0.32

0.31

10'

3'

A-44

1.5L(1.1L)

50

57

HC-301S

1'(25) 0.75 50 520

0.42

0.41

0.4

0.39

0.38

10'

31/2'

A-44

1.5L(1.1L)

50

57

HC-40S

11/4'(32)

0.75

50 500 0.66

0.65

0.63

0.61

0.59

12'

4'

A-52

2.5L(1.7L)

80

88
HC-401S 11/4'(32)

1.5

50 580

0.8

0.77

0.74

0.71

0.67

12'

41/2'

A-52

2.5L(1.7L)

85 93

HC-50S

11/2'(40)

1.5

50 430

1.14

1.12

1.09

1.06

1.02

14'

4'

A-64

3.5L(2.3L)

120

130

HC-501S

11/2'(40)

2.2

50 500

1.44

1.42

1.39

1.36

1.32

14'

41/2'

A-64

3.5L(2.3L)

125 135

HC-60S

2'(50) 2.2 50 450

1.9

1.87

1.82

1.77

1.71

16'

5'

B-74

5.5L(3.8L) 190

223

HC-601S

2'(50) 4 50 540 2.41 2.34 2.29 2.24 2.18 16' 6' B-74 5.5L(3.8L) 200 233

HC-80S

21/2'(65) 4 50 430 2.82 2.74 2.66 2.59 2.5 18' 51/2 B-84

8L(6L)

250 268

HC-801S

21/2'(65) 5.5 50 500 3.53 3.45 3.38 3.33 3.25 18' 6' B-84 8L(6L) 275 293

HC-100S

3'(80) 5.5 50 390 4.32 4.28 4.25 4.18 4.11 20' 51/2' B-93 20L(16L) 375 395

HC-1001S

3'(80) 7.5 50 420 5.41 5.32 5.25 5.18 5.11 20' 6' B-93 20L(16L) 390 410

HC-125A

4'(100)

7.5

50

390

6.87

6.82

6.78

6.63

6.58

20'

6'

B-93

30L(25L)

580

600

HC-125B

4'(100)

11

50

420

7.83

7.81

7.78

7.75

7.72

20'

6'

B-93

30L(25L)

600

620

HC-125C

4'(100)

11

50

500

9.20

9.10

9.0

8.80

8.70

20'

6'

B-93

30L(25L)

600

620