Corrosion resistant, wear-resistant, and widely adaptableThe YST183F-A50XL model is lined with materials such as chloroprene rubber, fluororubber, and polyurethane rubber, which can withstand the erosion and wear of acid, alkali, salt solutions, and suspended solids. It is suitable for various media such as sewage, chemical wastewater, and sand containing tap water.
Accurate measurement without pressure lossThis model has a measurement accuracy of ± 0.5% FS (standard operating conditions), excellent repeatability performance (≤ 0.1%), and no throttling components, which will not cause pipeline pressure loss and help the system reduce energy consumption.
Convenient maintenance and long lifespanNo mechanical moving parts design, reducing the risk of blockage and jamming. Only regular inspections of the electrode and lining status are required, and the service life can reach 5-8 years.
Flexible installation with strong adaptabilitySupport horizontal and vertical installation (when installed vertically, the fluid flows from bottom to top), with relatively loose requirements for straight pipe sections, and can adapt to complex installation environments such as municipal pipelines and factory workshops.
Nominal diameter: DN100 (actual diameter suitable for pipes with a diameter of 108mm or 114mm)
Lining materials: chloroprene rubber, fluororubber, polyurethane rubber, etc. (selected as needed)
Electrode materials: 316L stainless steel, Hastelloy C, titanium electrode, etc
Measurement range: Flow rate of 0.1-10m/s, corresponding to flow range of 0.00314-31.4m ³/h (calculated based on pipeline cross-sectional area)
Accuracy level: ± 0.5% FS (standard condition), ± 1.0% FS (harsh condition)
Work pressure: Conventional 1.6MPa (customizable 2.5MPa high-pressure version)
Medium temperature: -20 ℃~80 ℃ (the conventional tolerance range of rubber lining can be extended to 120 ℃ for special lining)
Dielectric conductivity: ≥ 5 μ S/cm
Output signal: 4-20mA analog signal, HART protocol, RS485 communication (Modbus protocol)
Protection level: IP65 (standard), IP68 (submersible installation version)
Power supply: AC 220V ± 10% or DC 24V ± 10%
Market guidance price: 5500.0 yuan (price may vary depending on parameter configuration)
Matching of medium characteristicsWhen customers choose the YST183F-A50XL type, they need to select lining materials based on the corrosiveness of the medium (such as fluorine rubber for strong acid media and polyurethane rubber for granular media), and confirm whether the conductivity of the medium meets the requirement of ≥ 5 μ S/cm.
Adaptation of working condition parametersConfirm that the working temperature and pressure of the medium do not exceed the rated range of the model, and the flow range is within the range of measuring flow velocity from 0.1-10m/s to avoid affecting the measurement performance at low flow rates.
Confirmation of installation conditionsSelect the installation method (horizontal/vertical) according to the pipeline layout, reserve sufficient straight pipe sections (upstream ≥ 5 times the pipe diameter, downstream ≥ 3 times the pipe diameter), and avoid strong magnetic field interference sources.
Functional requirement selectionSelect the output signal type (such as RS485 communication for remote monitoring) and protection level (IP65 for outdoor installation and IP68 for underwater installation) according to the usage scenario. We can provide corresponding configurations according to customer needs.
Wastewater treatment plant: YST183F-A50XL type is used for inlet and outlet flow measurement, aeration tank reflux flow monitoring, and sludge treatment system fluid measurement.
Waterworks: adapted to measure the flow rate of raw water intake and the outflow of clean water tank, and equipped with a dosing system for flow monitoring to ensure the accuracy of water supply scheduling.
Water purification plant: Helps to control the inflow and outflow of the filtration system, as well as the flow rate of each link in the pure water preparation process, to ensure the stability of the water purification process.
Municipal pipeline supply water: used for monitoring the flow of pipeline nodes, zoning metering management, leakage control, and ensuring the balance of water supply pressure and flow.
Environmental water treatment: Suitable for measuring the inflow and outflow flow of industrial wastewater treatment stations, monitoring environmentally compliant emissions, and matching the flow rate of water treatment agents.
Thermal heating: used for measuring hot water flow in heating pipelines, monitoring the distribution of heating flow in buildings and units, and assisting in thermal balance regulation.
Hospital wastewater treatment: Suitable for monitoring the flow rate of medical wastewater discharge, controlling the flow rate in the disinfection process, and meeting the requirements of medical wastewater discharge standards.
Chemical wastewater treatment: used for flow measurement of highly corrosive and suspended chemical wastewater, suitable for complex media scenarios such as acid, alkali, and salt.
River water quality monitoring: assisting in river water replenishment, ecological flow monitoring, flow monitoring before sewage flows into the river, and assisting in water environment management.
Smart rural water management: used for flow measurement of centralized water supply networks in rural areas, monitoring of irrigation water flow, and rational allocation and management of water resourcesRubber lined DN100 diameter electromagnetic flowmeterThe corresponding application is the adaptation of this model in such scenarios.
intelligent upgradeWe will integrate IoT modules for the YST183F-A50XL model, supporting remote data transmission, device status monitoring, and fault warning, adapting to the smart water management platform, and improving customer convenience.
High precision optimizationBy upgrading sensors and improving algorithms, further optimize the metrological performance of this model at low flow rates, and enhance the metrological stability in complex media.
Enhanced resistance to harsh environmentsDevelop special rubber lining and electrode materials that are resistant to high temperature, high pressure, and strong corrosion, and expand the application scenarios of YST183F-A50XL in more working conditions.
Low power consumption and modular designAdopting low-power circuit design, suitable for solar powered scenarios; The modular structure facilitates maintenance and component replacement, helping customers reduce maintenance costs.
Wastewater treatment plant customer: The YST183F-A50XL model from Dalian Yist has excellent resistance to pollution and blockage. It has never encountered blockage problems when treating wastewater containing suspended solids, and its measurement data is stable, meeting environmental discharge measurement requirements. The maintenance frequency is also very low.
Waterworks customer: The YST183F-A50XL DN100 pipe diameter is just suitable for our water supply pipeline, with high measurement accuracy and minimal deviation from third-party calibration data. The remote communication function facilitates real-time monitoring in the central control room, helping to optimize water supply scheduling.
Hospital wastewater treatment customer: The rubber lining of YST183F-A50XL has good corrosion resistance. It has been measuring medical wastewater containing disinfectants for a long time without damage to the electrodes and lining. The data is accurate and meets the monitoring standards for medical wastewater discharge.
Smart Rural Water Customer: The YST183F-A50XL model from Dalian Yister is easy to install and suitable for complex rural pipeline environments. Its low-power design is compatible with solar power supply, and its remote data transmission function allows us to real-time monitor the water supply flow of each village, making management very convenient.
Thermal heating customers: The YST183F-A50XL model has strong measurement stability for hot water flow, is not affected by changes in heating water temperature, accurate data helps with thermal balance adjustment, significantly reduces user complaint rates, and has low operating and maintenance costs.