Performance features: 32 points, 48 points, and 64 points for the main body, 8 points and 16 points for the expansion module, with a maximum configuration of 80 I/O points. Processing speed: average 4.7us/language, 3ms/500 language. Number of data registers: 1024 words, excluding T/C pass values. Special registers. User program capacity: 2.5K language. EEPROM storage can be divided into AC85~264V and DC24V power supply models
Performance Features:
The main body has 32 points, 48 points, and 64 points, the expansion module has 8 points and 16 points, and the maximum configuration of I/O points is 80 points
Processing speed: average 4.7us/language, 3ms/500 language
Number of data registers: 1024 words, excluding T/C values, special registers
User program capacity: 2.5K languages, EEPROM storage
There are two types of working power supply models: AC85~264V and DC24V; AC models provide 24V power supply for sensors
The entire series of products come with one RS232 communication port, which can complete A-type, B-type, CCM2, and protocol free communication functions
SH2 adds an RS485 communication port compared to SH1, supporting MODBUS RTU communication and Mode 70 protocol free communication
Performance specifications:
|
project
|
SH1/2-32
|
SH1/2-48 |
SH1/2-64 |
|
I/O transmission method
|
Simultaneous transmission method, direct output and interruption function
|
|
programming language
|
Trapezoidal diagram and hierarchical sharing
|
|
Instruction type
|
135 records (52 in sequence, 23 in control, 60 in data processing) (SH2:136 records)
|
|
processing speed
|
An average of 4.7 USD/language, 3ms/500 language
|
|
Power outage maintenance
|
Optional battery addition
|
|
Number of data registers
|
1024 words, excluding T/C values, special register
|
|
User program capacity
|
2.5K language, EEPROM storage
|
|
I/O point count
|
32 points (basic) 40 or 48 points (with extension)
|
48 points (basic) 56 or 64 points (with extension) |
64 points (basic) 72 or 80 points (with extension) |
|
Number of internal coil points
|
256 points
|
|
level
|
256 points
|
|
Shift register (R)
|
Internal coil as displacement object
|
|
Timer (T)
|
128 points (0.1s 0.01s)
|
|
Counter (C)
|
128 points (0-9999)
|
|
Timed scanning interval setting
|
(0-99) * 2ms can be set
|
|
protection method
|
Password function
|
|
Special Input/Output Function
|
Software filtering input 4 points (0-99) x 2ms can be set High speed counter/external interrupt 2 points, counting speed 2KCPS (SH2:5KCPS), can form 8 modes
|
|
communication function
|
SH1/SH2: RS-232C communication port, supporting A-type, B-type, CCM2 (substation) and protocol free communication functions; SH2: RS-485 communication port, supporting MODBUS RTU communication and Mode 70 protocol free communication.
|
Model List:
| model |
type |
model |
type |
power supply |
| SH1/2-32R1 |
16:00 24VDC/16:00 relay |
SH1/2-48R1 |
24 o'clock 24VDC/24 o'clock relay |
AC85-264V |
| SH1/2-32T1 |
16:00 24VDC/16:00 transistor |
SH1/2-48T1 |
24 point 24VDC/24 point transistor |
| SH1/2-32R1-C |
16:00 24VDC/16:00 relay |
SH1/2-48R1-C |
24 o'clock 24VDC/24 o'clock relay |
DC24V |
| SH1/2-32R2 |
20 o'clock 24VDC/12 o'clock relay |
SH1/2-48R2 |
28pm 24VDC/20pm relay |
AC85-264V |
|
|
|
SH1/2-48T1-C |
24 point 24VDC/24 point transistor |
DC24V |
| SH1/2-32R2-C |
20 o'clock 24VDC/12 o'clock relay |
SH1/2-48R2-C |
28pm 24VDC/20pm relay |
|
|
|
SH1/2-48T2-C |
28 point 24VDC/20 point transistor |
| SH1/2-64R1 |
32 point 24VDC/32 point relay |
SH1/2-64R2 |
36pm 24VDC/28pm relay |
AC85-264V |
| SH1/2-64R1-C |
32 point 24VDC/32 point relay |
SH1/2-64R2-C |
36pm 24VDC/28pm relay |
DC24V |
Expansion unit:
| model |
I/O type |
power supply |
| H1-16ND1 |
16:24 VDV input |
No power required |
| H1-16TR1 |
16 point relay output |
| H1-16 CDR1 |
8 o'clock 24VDC/8 o'clock relay |
| H1-4AD2DA |
4 analog inputs/2 analog outputs |
| H1-4AD |
4-channel analog input |
| H1-2DA |
2-channel analog output |
Communication:
RS-232C:
| project |
Create a programming port |
As a communication port |
| signal |
RS-232C standard (non insulated) |
| Transmission speed |
9600bps |
Special register settings |
| Transmission distance |
Below 3m |
Below 15m |
| connect |
Six pin telephone socket |
| connected device |
S-200HP DirectSoft software |
Serial communication equipment |
| data format |
HEX |
ASCII and HEX are optional |
| Bureau number |
fixed |
Special register settings |
| agreement |
Programmer specific protocol CCM2 protocol communication (slave function) Type A/B, no protocol communication |
RS-485:
| project |
Instructions |
| signal |
Three wire RS-485 (non insulated) |
| Transmission speed |
Special register settings |
| connect |
3-terminal desktop, supporting 1 to many connections |
| connected device |
Serial communication equipment |
| Transmission distance |
Below 1000 meters |
| data format |
Special register settings |
| agreement |
MODBUS RTU/No protocol |
| Bureau number |
MODBUS RTU station number 1-247 |
Dimensions (unit: mm):
| model |
long |
wide |
tall |
| SH1/2-32 |
160
|
90
|
90
|
| SH1/2-48 |
216
|
| SH1/2-64 |
262
|
|