KHCOD-8G high chlorine wastewater standard COD digestion device, * in accordance with HJ/T 70-2001 high chlorine wastewater chemical oxygen demand determination CL calibration method. The $r $n instrument adopts microcomputer technology for timed control of the heating plate, which can simultaneously heat and digest 8 250ml conical flask reflux devices. The $r $n instrument adopts a glass burr reflux tube instead of a spherical reflux tube, and uses air cooling technology instead of tap water cooling, which can save water and standardize the instrument. Preparation, operation, and COD calculation of chemical solutions for instruments. $r $n is suitable for oil fields, coastal oil refineries, oil depots, chlor alkali plants, deep-sea wastewater discharge, etc
Product Details

KHCOD-8G typeHigh chlorineWastewater standardsCOD digestionDevice,*According to HJ/T 70-2001Determination of Chemical Oxygen Demand for High Chlorine Wastewater by CL Gas Calibration Method.

The instrument adopts microcomputer technology for timed control heatingboardYes, yes8a250mlSimultaneous heating of conical flask reflux deviceresolve.

The instrument adopts a glass burr reflux tube instead of a spherical reflux tube, and uses air cooling technology instead of tap water cooling, which can save water and standardize the instrument. Preparation, operation, and COD calculation of chemical solutions for instruments.

Suitable for the determination of COD in wastewater from oil fields, coastal oil refineries, oil depots, chlor alkali plants, and deep-sea wastewater discharge.

Technical Specifications

1Anti chlorine interference: 1000-20000mg/L

  1. Nitrogen flow rate:6~60mL/min

3Measurement range: ≤ 1000mg/L (greater than dilution)

4Dissolving time: 2hour30 minutesAdjustable time

5Dissolving volume: 250mL

6Measurement error: ≤ 500mg/L, relative standard deviation not greater than 5.0

≤1000mg/L, The relative standard deviation is not greater than 8.0%

7Heating power:1600W(220V,50HZ)

8Cooling method:dual-fanair coolingAdd water for cooling

9. Microcrystalline plate heating table, make 8 samples

Instructions for using the buttons on the front panel of the instrument

  • blowwind

Control the opening and closing of the fan.

  • fixedtime

Dissolve time control setting key. The instrument is set to power on for 2 hours and 30 minutes. Each press of the setting key automatically deducts 10 minutes,Determine by standard reflux methodCODThe time should be set to 2 hours.

  • start

Start control button for digestion. After pressing the "Start" button, the instrument will perform heating reflux digestion and automatically count down from the set value (such as 2 hours). The heating indicator light will turn on. When the set time is reached, the instrument automatically stops heating and the heating indicator light goes out.

4. The front panel of the instrument has8Only flow meters.