E-mail
89404032@qq.com
-
Phone
13811233305
-
Address
1002 Hanhai Great Wall Building, Shijingshan Road, Shijingshan District, Beijing
Beijing Huayirui Technology Co., Ltd
89404032@qq.com
13811233305
1002 Hanhai Great Wall Building, Shijingshan Road, Shijingshan District, Beijing
Surface layer of soilCO2There are many studies on flux, but these monitoring methods are not sufficient to explain soilCO2Production process, soil profileCO2Vertical gradient research is increasingly becoming a hot topic in soil respiration and even ecosystem carbon cycling research. Different layers (depths) of soilCO2Continuous monitoring of production is crucial for understanding soilCO2Dynamics are extremely important as they can elucidate the transition from soil to atmosphereCO2The variation characteristics of flux with season, light, temperature, humidity, and soil characteristics.
Vertical gradient of soilCO2Monitoring can be compared with widely used eddy related monitoring to quantitatively study and analyze carbon exchange in ecosystems.
There are currently two methods for soil gradient:
1. Directly bury the CO2 sensor in the soil Gradient based monitoring of concentration distribution in each layer, simple to use, with two types of precision sensors to choose from,
GMP343 and GMP22X series:
|
GMP343 |
GMP22X |
Measurement method: |
Diffuse and pump suction |
Diffuse and pump suction |
Measurement range: |
0 . .. 1000 ppm, 0 . ..2 000 ppm |
GMP221 probe 0 .. 2 %, 0 . .. 3 %, 0 . .. 5 %, 0 . .. 10%, 0 . .. 20 % CO2 |
Accuracy: |
0 1000 ppm: ± (3 ppm+1% reading) 0 .. 2000 - 0 . 2%: ± (5 ppm+2% reading) |
± (1.5% range+2.0% reading) |
Working temperature: |
-40~60°C |
-20~60 ° C (probe) |
Working humidity: |
0 |
0 |
Shell: |
Electroplated aluminum, PC plastic IP66/IP67 |
PC plastic IP66/IP67 |
2. Online multi-layer analysis of soil concentration data using infrared analyzer
System advantages:
vUsing an analyzer to analyze multi-layer data,No systematic errors
vOther measuring element analyzers can be replaced,if:N2O,CH4Equal gradient measurement content,More flexible experiments
vhigh precision,Easy to use and maintain.The whole machine is simpler and more convenient to use than soil breathing systems
CO2/H2O analyzer technical specifications
|
CO2 analyzer |
H2O analyzer |
|||
range |
0~20,000 μmol/mol |
0~60 mmol/mol |
|||
accuracy |
1% better than the reading |
1.5% better than the reading |
|||
Calibration drift |
zero drift |
<0.15 μmol/mol/℃ |
<0.003 mmol/mol/℃ |
||
Span drift |
<0.03 %/℃ |
<0.03 %/℃ @ 10 mmol/mol |
|||
Total drift |
<0.4 μmol/mol/℃ @ 370 μmol/mol |
<0.009 mmol/mol/℃ @ 10 mmol/mol |
|||
RMS noise |
1 second signal filtering |
<1 μmol/ mol@370 μmol/mol |
<0.01 mmol/ mol@10 mmol/mol |
||
sensitivity |
CO2 |
—— |
<0.0001 mmol/mol H2O/ μmol/mol CO2 |
||
H2O |
<0.1 μmol/mol CO2/ m mol/mol H2O |
—— |
|||
Measuring principle |
Non dispersive infrared analysis |
light source lifetime |
~18,000 h |
||
standard |
CO2 |
World Meteorological Organization standards |
power supply |
12~30 V DC |
|
H2O |
LI-610 Portable Generator NIST Standard |
||||
Pressure compensation range |
15~115 kPa |
Working temperature range |
-20~45℃ |
||
*Atmospheric velocity rate |
1 L/min |
Relative humidity range |
0~95% (non condensing) |
||
output signal |
2 analog voltage outputs, 2 current outputs |
volume |
22.2 L×15.3 W×7.6 H cm |
||
Digital output: TTL (0-5V) or open circuit |
weight |
1 kg |
|||
Internal cavity volume |
14.5mL |
Power requirements |
12~30 V DC, 14 W during preheating and 3.6 W during stabilization |
||
According to Fick's first law, the flow rate of diffusing material per unit cross-sectional area perpendicular to the diffusion direction per unit time (in the case of steady-state diffusion) is calledDiffusion fluxDiffusion flux, 用JAt this section, theconcentration gradientThe concentration grade is directly proportional. Soil profile CO2Flux(μmol CO2 m−2s−1)According to this law, the specific calculation formula is:
J= -D(dC/dx)
among whichDforDiffusion coefficient of CO2 in soil (unit: m)2/s, C is the concentration of CO2 at a depth of x (in meters), which is related to soil temperature, soil volume moisture content, and soil porosity,dC/dxFor concentration gradient,The "-" sign indicates that the diffusion direction is opposite to the concentration gradient, that is, diffusion spreads from the high concentration area to the low concentration area.
Characteristics of the system:
1. Non disturbance in-situ continuous measurement of soil profile CO2Moisture and temperature (standard configuration is3-8 layers are optional), and soil CO can be calculated using Fick's law2Flux (soil respiration) is used to achieve continuous and stable in-situ monitoring of soil respiration.
2. Three parameter intelligent sensor for soil, measuring soil moisture, temperature, and salinity.
3. Transparent or non transparent soil respiration chamber method (optional) for measuring surface soil respiration, which can be used to supplement, calibrate, or compare soil profile CO2Gradient measurement data.
4. Wireless data transmission allows for online browsing and downloading of data at any time.
5. AC battery power supply or solar power supply.
Main technical indicators:
1. Soil moisture measurement:
·measurement range0Volume water content, degree± 1%, repeatability accuracy ±0.2%,;
·Range of soil temperature measurement:-40℃~70℃, measurement accuracy: ±0.2℃
2. Soil CO2 measurement: Non dispersive single beam dual wavelength infrared technology (NDIR), measurement range 0-5000ppm, 0-7000ppm, 0-10000ppm, 0-20000ppm optional, accuracy ± 1.5%, response time 3 seconds;
3. Standard 16 channel data collector (optional 32 channels to monitor CO2 concentration, soil moisture, and soil temperature above 3 layers):
·storable220000Group data with timestamp,16Bit resolution,± 20 mV up to ± 2.5 V 8 range input, degree0.03%;
·Measurement interval3Seconds to4Adjustable hours, average data interval3Seconds to4Hour;
4. Wireless data transmission, browsing and downloading data through software terminals, and conducting statistical analysis on the data.