1、 Product Overview
The TCB3 digital gas detector is characterized by the use of catalytic combustion, electrochemical, and infrared dual beam gas sensors, combined with sophisticated SMD technology manufacturing. It has good repeatability and resistance to humidity and temperature interference, long service life, and easy operation. Suitable for detecting gas leakage concentration in various industrial environments.
The TCB3 digital gas detector can convert the concentration signal of leaked gas in the air into an electrical signal for remote transmission. It adopts signal structures such as three wire 4-20mA, four wire RS485 bus, passive switch quantity, etc. The monitoring instrument or controller host is far away from the site to observe the detection results.
The TCB3 digital gas detector product is suitable for gas safety detection, alarm and control in industrial sites such as refineries, chemical plants, liquefied gas stations, gas boiler rooms, refueling stations, paint spraying rooms, pharmaceuticals, iron and steel smelting where flammable and explosive materials, toxic and harmful substances are used.
2、 Performance characteristics
1. Long lifespan, high sensitivity, low drift, stable and reliable operation
2. Sensor fault self check, two * concentration alarm, with relay output function
3. LCD or digital display of gas concentration and working status
4. Equipped with temperature compensation and automatic zero point correction function
5.4-20mA standard analog output and RS485 digital output, can be uploaded to DCS and PLC systems
6. Infrared remote control or magnetic rod control method, the detector can be adjusted without opening the cover, which is safe and convenient
7. Adopting explosion-proof design suitable for hazardous conditions Zone 1 and Zone 2
3、 Technical parameters
1. Detection principle: catalytic combustion, electrochemical, infrared, thermal conductivity
2. Gas usage: toxic gas VOC、 Oxygen, carbon dioxide (see technical parameters)
3. Sampling method: natural diffusion;
4. Environmental temperature: -40 ℃ to 70 ℃;
5. Relative humidity:<95%;
6. Explosion proof type: explosion-proof type;
7. Explosion proof rating *: Ex d IIC J6 Gb;
8. Power supply: DC24V ± 25%;
9. Power consumption: 3W/channel;
10. Use cables: 1.5mm2 × 3 (three wire system) and 1.5mm2 × 4 (four wire system) cable wires;
11. Transmission distance: ≤ 1000m;
12. Instrument size: 180 * 140 * 76 (mm);
13. Whole machine weight: ≤ 650g;
14. Structural material: Die cast aluminum
15. Electrical interface: 20mm * 1.5mm (G1/2 optional)
|
Tested gas |
measurement range |
Optional range |
resolution |
response time |
|
Flammable EX |
0-100%LEL |
0-100% VOL (infrared) |
1%LEL/1%vol |
≤ 15 seconds |
|
Oxygen O2 |
0-30%VOL |
0-30%VOL |
0.1%vol |
≤ 15 seconds |
|
Hydrogen sulfide H2S |
0-100PPm |
0-50、200、1000PPm |
0.1/1PPm |
≤ 15 seconds |
|
Carbon monoxide CO |
0-1000PPm |
0-500/2000/5000PPm |
0.1/1PPm |
≤ 15 seconds |
|
Nitrogen dioxide NO2 |
0-20PPm |
0-50、1000PPm |
0.1/1PPm |
≤ 20 seconds |
|
Carbon dioxide CO2 |
0-5000PPM |
0-1%, 5%, 10% VOL (infrared) |
1PPM/0.01%VOL |
≤ 20 seconds |
|
Nitric oxide NO |
0-250PPm |
0-500、1000PPm |
1PPm |
≤ 20 seconds |
|
Sulfur dioxide SO2 |
0-20PPm |
0-50、1000PPm |
0.1/1PPm |
≤ 20 seconds |
|
Chlorine gas CL2 |
0-20PPm |
0-10、100PPm |
0.1PPm |
≤ 20 seconds |
|
Ammonia NH3 |
0-100PPm |
0-50、500、1000PPm |
0.1/1PPm |
≤ 20 seconds |
|
Hydrogen H2 |
0-100%LEL |
0-1000ppm |
1%LEL/1ppm |
≤ 20 seconds |
|
Phosphine PH3 |
0-20ppm |
0-20、 0-100PPM |
0.1PPM |
≤ 20 seconds |
|
Hydrogen chloride HCL |
0-20PPm |
0-20、50、100PPm |
0.01/0.1PPm |
≤ 20 seconds |
|
CLO2 dioxide dioxide |
0-50PPM |
0-10、100PPm |
0.1PPm |
≤ 20 seconds |
|
Hydrogen cyanide HCN |
0-50PPM |
0-100PPm |
0.1/0.01PPm |
≤ 20 seconds |
|
Ethylene oxide ETO |
0-100PPM |
0-100PPm |
1PPM/0.1PPM |
≤ 20 seconds |
|
Ozone O3 |
0-10PPm |
0-20、100PPm |
0.01PPm/0.1PPM |
≤ 20 seconds |
|
Formaldehyde CH2O |
0-20PPm |
0-50、100、PPm |
1/0.1PPm |
≤ 20 seconds |
|
Fluorine gas F2 |
0-10ppm |
0-1、10PPm |
1PPM/0.1PPM |
≤ 20 seconds |
|
Hydrogen fluoride HF |
0-10PPm |
0-1、10、50、100PPm |
0.01/0.1PPm |
≤ 20 seconds |
|
Xylene, toluene |
0-20PPm |
0-5、10、50、100PPm |
0.01/0.1PPm |
≤ 20 seconds |
|
For gases not listed, please contact our company |
||||