E-mail
qdbxhb@sina.com
-
Phone
138-0898-3386
-
Address
101, Unit 4, Building 4, No. 280 Shuyuan Road, Licang District, Qingdao City
Qingdao Bixi Environmental Protection Instrument Co., Ltd
qdbxhb@sina.com
138-0898-3386
101, Unit 4, Building 4, No. 280 Shuyuan Road, Licang District, Qingdao City
TIGER LT can provide you with accurate and reliable measurement results. TIGER LT can provide you with accurate measurement results in the shortest possible time, whether you are in a humid or dusty environment, whether you are wearing protective equipment or conducting headspace checks to comply with environmental regulations.
1. Accurate measurement range in all environments: 0.1-5000ppm
2. Moisture resistant to 99% RH, no humidity compensation required
3. Anti fouling design reduces reading drift and extends working time
4. 2 seconds fastest response time, quickly return to zero
Reduce downtime
1. Anti pollution design reduces calibration frequency
2. 24-hour continuous use of lithium batteries
3. 6.5 hours of charging, maximizing normal operating time
4. The battery can be replaced in explosive environments
5. Replace filters and lights within minutes
Easy to use
1. Optional correction factor directly measures concentration to obtain readings
2. Intuitive and easy-to-use software, with simple overall design and maintenance
3. The buttons are large and clear, and are also easy to operate with one hand when wearing gloves
4. Simple Chinese icon style menu, clear large screen
5. Backlit buttons and flashlight lighting design suitable for operation in dim environments
6. Manual data storage, 128 storage areas, 80000 data points
Inherent safety and low cost
1. 95dB speaker, bright LED and vibration alarm
2. Certified by ATEX, IECEx, UL, and CSA for intrinsic safety
3. Basic VOC detector
4. Cheap spare parts, low-cost operation
Minimum resolution: 0.1ppm
Range: 0.1-5000ppm
Response time: T90<2 seconds
Accuracy: ± 5% reading or ± 1 value
Linear: ± 5% reading or ± 1 value
Intrinsic Safety Certification: II 1G Ex ia IIC T4 Ga
Tamb= -15℃≤Ta≤+45℃
ITS09ATEX26890X IECEx ITS 10.0036X
3193491 conforms to UL Std. 913, 61010-1 &
Certified to CAN/CSA Std. C22.2 No. 61010-1
Lithium battery: up to 24 hours of continuous use
PID lamp: 10.6eV krypton PID lamp (standard type) 10.0eV and 11.7eV lamps are optional
Data storage: manually record 128 areas, 80000 points
Calibration: Standard calibration of 100ppm isobutene
Alarm: LED flashing light and 95 dBA 300mm (12 '') speaker, optional vibration alarm
Flow rate: 220ml/min with low flow alarm
Temperature: Operating temperature: -20~60 ℃, -4~140 ℉
Humidity: 0~99% RH (without condensation)
Protection level: IP65 waterproof design
CE1180
EMC tested to EN61326-1:2006, EN50270: 2006 & CFR
47:2008 Class A
Weight and volume: Width 340 x Height 90 x Depth 60mm (13.4 x 3.6 x 2.4 '')
Instrument weight: 0.72kg (1.56lb)
The above technical specifications are based on calibration results under conditions of 20 ℃, 90% RH, and a concentration of 100ppm isobutene. It depends on the gas.
Environmental monitoring; Soil pollution detection; VOC's from landfill sites; Indoor air quality monitoring; Occupational health and safety; Access to confined spaces; Quick response; Wing fuel tank inlet; VOC leakage detection; Fumigation gas; Unconventional emissions; Medical gases, etc.