1、 Product Overview
The continuously increasing fuel costs have made it increasingly important to use flue gas analysis to improve the combustion efficiency of boilers. A practical, easy-to-use, and portable smoke analyzer is the testo 340, which comes standard with only an O2 sensor. The other three sensors can be selected and matched according to different applications. The compact design and reliable technology make the testo 340 suitable for various applications, including:
• Environmental monitoring;
• Energy saving monitoring;
• Inspection of fixed engines;
• Turbine inspection
Pre calibrated plug and play backup sensor
3 freely selectable sensor slots (standard O2, at least 2 sensors to work) CO, COlow, NO, NOlow, NO2, and SO2
Testeo 340 comes standard with differential pressure/flow rate measurement function
Range extension function, standard for single sensor range extension or optional for all sensor range extensions
Automatic flow control air pump
Modular smoke probe
Data storage function
Configuration: Data transfer, connected to EasyEmission computer software via USB
10 built-in fuels, 10 user-defined fuels - fuel coefficient can be calculated through easyEmission software
The testo 340 requires at least 2 sensors to operate, and can be equipped with up to 4 sensors
2、 Technical parameters
|
Technical Specifications |
|
|
monitor |
Graphic display: 160 x 240 pixels |
|
Storage temperature |
-20 ~ +50 °C |
|
Operating temperature |
-5 ~ +50 °C |
|
weight |
960 g |
Industrial flue gas probe - standard system
|
image |
Instructions |
Order Number |
|
|
Thermocouple, NiCr Ni, -200~+1200 ° C, 1.2 m long |
|
|
|
Thermocouple, NiCr Ni, -200~+1200 ° C, 2.2 m long |
|
|
|
Thermocouple, NiCr Ni, -200~+1200 ° C, 3.2 m long |
|
|
|
Pre filter, ceramic |
|
|
|
Install flange, 1.4571 stainless steel |
|
|
|
Unheated sampling tube, temperature resistance+600 ° C |
|
|
|
Extended sampling tube, temperature resistance+600 ° C |
|
|
|
Unheated sampling tube, temperature resistance+1200 ° C |
|
|
|
Unheated sampling tube, temperature resistance+600 ° C |
|
|
|
Unheated sampling tube, temperature resistance+1800 ° C, corundum |
|
|
|
Simple handle, non heating |
|
Probe options
|
image |
Instructions |
Order Number |
|
|
Spare stainless steel sintered pre filter (2 pieces/pack) |
|
|
|
Extend the connecting hose, 2.8 meters, used to extend the hose between the probe and analyzer |
|
|
|
Spare stainless steel sintered pre filter (2 pieces/pack) |
|
|
|
Probe sleeve, 335 mm long, with fixed cone, Ø 8 mm, temperature resistant to 1000 ° C |
|
|
|
Probe sleeve, 700 mm long, with fixed cone, Ø 8 mm, temperature resistant to 1000 ° C |
|
|
|
Probe sleeve with pre filter, 335 mm long, with fixed cone, Ø 8 mm, temperature resistant to 1000 ° C |
|
|
|
Probe sleeve with pre filter, 700 mm long, with fixed cone, Ø 8 mm, temperature resistant to 1000 ° C |
|
|
|
Probe sleeve, 335 mm long, with fixed cone, Ø 8 mm, temperature resistant to 1000 ° C |
|
Smoke probe
|
image |
Instructions |
Order Number |
|
|
Modular smoke probe, 335 mm long, with fixed cone and thermocouple, temperature resistance of 1000 ° C and 2.2 m sulfur resistant tube |
|
|
|
Modular smoke probe, 700 mm long, with fixed cone and thermocouple, temperature resistance of 1000 ° C and 2.2 m sulfur resistant tube |
|
|
|
Modular smoke probe with pre filter, 335 mm long, equipped with fixed cone and thermocouple, temperature resistant to 1000 ° C and 2.2 m sulfur resistant tube |
|
|
|
Modular flue gas probe with pre filter, 700 mm long, with fixed cone and thermocouple, temperature resistance of 1000 ° C and 2.2 m sulfur resistant tube |
|
|
|
Modular smoke probe, 335 mm long, with fixed cone and thermocouple, temperature resistance of 500 ° C and 2.2 m sulfur resistant tube |
|
|
|
Modular smoke probe, 700 mm long, with fixed cone and thermocouple, temperature resistance of 500 ° C and 2.2 m sulfur resistant tube |
|
Pitot tube
|
image |
Instructions |
Order Number |
|
|
Straight skin tube, stainless steel, 350 mm long, used for measuring flow rate and temperature, including 3 hoses (5 m long) and insulation disc |
|
|
|
Straight leather tube, stainless steel, 750 mm long, used for measuring flow rate and temperature, including 3 hoses (5 m long) and insulation disc |
|
|
|
Stainless steel pitot tube, 350 mm long, connected to pressure probe, capable of measuring wind speed (Combined with pressure probe//or built-in sensor of testo 521) |
|
|
|
Stainless steel pitot tube, 1000 mm long, connected to pressure probe, capable of measuring wind speed |
|
temperature probe
|
image |
Instructions |
Order Number |
|
|
Mini ambient air probe, Tmax+80 ° C, used for single * measurement of ambient air temperature |
|
|
|
Pipe clamp probe, used to measure the surface temperature of pipes with a large diameter of 2 ' |
|
|
|
Combustion air temperature probe, inserted at a depth of 60mm |
|
|
Attachment Instructions |
Order Number |
|
Optional: CO (H2 compensation) sensor, 0~10000 ppm |
|
|
Optional: COlow (H2 compensation) sensor, 0~500 ppm |
|
|
Optional: NO sensor, 0~3000 ppm |
|
|
Optional: Nolow sensor, 0~300 ppm |
|
|
Optional: NO2 sensor, 0~500 ppm |
|
|
Optional: SO2 sensor, 0~5000 ppm |
|
|
Optional: Range extension for all sensors |
|
|
Instrument box |
|
|
Backup CO sensor chromatography filter |
|
|
Backup NO sensor chromatography filter |
|