The range length of turbidity dust monitoring instrument can be selected as desired

NegotiableUpdate on 02/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The range length of the turbidity dust monitoring instrument can be selected to provide real-time warning of high concentration dust, avoiding explosion risks and ensuring the safety of personnel and equipment. Reduce energy consumption of dust removal equipment, minimize raw material loss, and extend equipment lifespan.
Product Details

The range length of turbidity dust monitoring instrument can be selected as desiredIt is one of the important equipment to ensure the safe and environmentally friendly operation of dust removal equipment systems. It can integrate operation, display, alarm, and system operation status traceability, achieve real-time online monitoring of dust concentration in the clean air chamber of the dust collector, prevent dust concentration exceeding the standard due to factors such as bag dropping and leakage during operation, eliminate hidden dangers, improve equipment safety guarantee, timely, continuously, and accurately reflect equipment operation status, avoid safety accidents, and reduce equipment accident rate.

The range length of turbidity dust monitoring instrument can be selected as desiredProduct function

Safety protection: Real time warning of high concentration dust, avoiding explosion risks, and ensuring the safety of personnel and equipment.

Environmental compliance: Provide accurate emission data to help companies cope with environmental inspections and avoid fines.

Health protection: Reduce the occurrence of occupational diseases and improve employee job satisfaction.

Production optimization: Adjust process parameters through data feedback to improve production efficiency and product quality.

Cost savings: reduce energy consumption of dust removal equipment, minimize raw material loss, and extend equipment lifespan.

Precautions for use

Installation location: Priority should be given to vertical pipelines, away from valves and elbows; Avoid sedimentation areas at the bottom when installing horizontal pipelines.

Environmental interference: Avoid high humidity, strong vibration, or corrosive gas environments, and install protective covers if necessary.

Regular calibration: Calibrate equipment according to the manufacturer's recommended cycle and verify accuracy using standard reference materials.

Cleaning and maintenance: Although it has self-cleaning function, it is still necessary to regularly check the surface of the sensor to prevent stubborn accumulation.

Compliance: Ensure that the equipment complies with local environmental regulations and that the installation and operation processes meet safety standards.

Data utilization: Combining historical data with real-time trends to optimize production processes and emergency plans.

technical specifications

Operating environment temperature

-20 ℃~60 ℃ (electronic components)

Operating environment humidity

Non condensing 90%

Operating environment vibration

Maximum continuous oscillation, any direction, any frequency: root mean square value 2g (20m/s2)

Operating environment electromagnetic field

At 50 HzZui high value=60A/m (equivalent to a magnetic field of 50AT inside a 1m x 1m square electromagnetic coil)

Protection of operating environment

Protection level: IP66/NEMA4 aluminum alloy shell, suitable for installation in non corrosive environments, stainless steel probe

Pipeline gas pressure

-0.1-1MPa (maximum up to 8MPa)

Pipeline gas flow rate

1m/s~30m/s

Pipeline gas temperature

Real time temperature: 200 ℃, instantaneous temperature: 260 ℃ (260 ℃ -800 ℃ can be customized)

outer diameter of pipe

0.1 meters to 4 meters

Probe structure

The standard probe is 16mm in diameter, with a length ranging from 100mm to 1000mm. The probe material is rare earth amorphous alloy,

Dust particle size range

The nominal range is 0.1 μ M to 200 μ M, and it can still receive signals outside the nominal range, but the signal characteristics are slightly different.

Powder material

Including: dust, coal powder, flour, dust, smoke, graphite, manganese dioxide, quicklime and other various particulate matter

zero drift

(Time) Less than 1% of the range per year.

zero drift

Within the specified temperature range, below 1% of the measuring range.

Full-scale drift

(Time) Less than 1% of range per year

Full-scale drift

Within the specified temperature range, below 1% of the measuring range.

Line stability

All components of the system are made of high stability electronic assemblies.

Noise resistance

All 50 or 60 Hz audio and harmonics are filtered out before the signal is received

measurement range

0-10mg/50mg/100mg/200mg/1000mg/30g/100g/m ³ (customized for special ranges)

Transmitter output mode

Standard 4-20mA (two-wire system) (customizable switch quantity, RS485 communication, Modbus RTU protocol, HART protocol, etc.)

Transmitter power supply

24V (available within the range of 15V to 32V)

measurement accuracy

±1%

Probe length selection

Please select the probe length according to the formula, i.e. D/3 ≤ L ≤ 2D/3

(Among them: D - Inner diameter of pipeline, L - Probe length)

Explosion-proof marking

Exia IIC T6 Ga/ExoD 21 T80 ℃ Certificate Number: CNV21.0092X

Ex db IIC T6 Gb, Ex tb IIC T80 ℃ Db Certificate Number: CNV24.1117X