UV-150AF type ultraviolet sterilizer

Product features:
The removal rate of various viruses and bacteria from seawater, freshwater, or other water bodies treated by the UV disinfection system can reach over 99.99%.
Under the premise of achieving a removal rate of over 99.99% for viruses and bacteria in water bodies, the cost of treating each ton of water with a UV sterilizer ranges from 4 cents to 1 cent RMB.
Three ultraviolet disinfectors have improved the survival rate of seawater and freshwater seedlings, with a survival rate of over 50%.
4 UV sterilizers accelerate the growth rate of aquaculture populations.
The UV sterilizer can remove pathogenic bacteria and other pathogens with a removal rate of over 99.99% without changing the original ingredients, taste, and color of various beverages and other fluid foods.
6. Low operation and maintenance costs: UV sterilization equipment occupies a small area and has simple structural requirements, so the total investment is relatively small. In terms of operation costs, it is also relatively low. At the level of 1000 tons of water treatment capacity, its cost is only half of chlorine disinfection
The use of the 7 ultraviolet sterilizer is simple. It is directly connected to the pipeline to disinfect and sterilize the flowing water. Its effect is significant, economical and durable, with low investment and no secondary pollution.
Technical parameters:
1. Environmental conditions
Environmental temperature: 0 ° C~+50 ° C, with no corrosive gases inside
Relative humidity: not exceeding 93% (at a temperature of 25 ℃)
The equipment should be installed indoors to prevent exposure to sunlight and rain
The room should be ventilated and dry, the floor should be clean, and there should be no dust. Attention: Dust and corrosive gases can cause damage to electrical components, affecting their effectiveness and lifespan.
2 Water quality conditions
Turbidity ≤ 5 degrees
Total iron content ≤ 0.3mg/L
Chromaticity ≤ 15 degrees
Water temperature ≥ 5 ℃
Total coliform count ≤ 1000/L
Total bacterial count ≤ 2000/mL
3 Working conditions
Water temperature: 5 ℃ -60 ℃ 1) Voltage: 220V ± 20V, 50Hz 2) Chromaticity: ≤ 15 degrees
Equipment pressure: ≤ 0.6MPa3) Turbidity: ≤ 5NTU
Cleaning interval time: standard type 7 days/time
Iron content: ≤ 0.3mg/L (adjustable), pneumatic cleaning type, 24-hour/time
Manganese content: ≤ 0.05mg/L (adjustable), 17min each time (adjustable)
Hardness: 120mg/L (CaCo3) 4) Connection method: flange (optional) 7) Total bacterial count: ≤ 2000/mL
Selection reference