Vacuum suction equipment high-pressure fan

NegotiableUpdate on 03/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The high-pressure fan of the vacuum suction equipment adopts a high-tech energy-saving all copper wire wound coil, and the casing is made of high-strength aluminum alloy and the motor casing is die cast in one day. The blades have undergone computer balancing correction and high-precision mechanical processing to reduce vibration. When the impeller rotates, it does not come into contact with any components and is lubrication free, ensuring no oil or gas, making it more environmentally friendly and efficient!
Product Details

Jiangsu Environmental Protection Technology Co., Ltd. specializes in the production and sales of suction blowers, high-pressure suction blowers, suction blowers, industrial suction blowers, feeding blowers, suction feeding blowers, vacuum feeding blowers, etc. The product models are complete, and the performance characteristics include long range, high pressure, large air volume, low noise, lightweight, and more detailed product information. Welcome to guide

Vacuum suction equipment high-pressure fanFeatures:

1. The research and design of the product adopt German technology, using ADC12 aluminum for one-time die casting and high-precision CNC machining;

2. The insulation level of the motor is TEFC IP54 standard, with an insulation level of F, and the body can withstand temperatures up to 180 degrees;

3. The motor meets the European EFF2 standard, which is particularly energy-efficient and durable;

4. The new design of the front bearing ensures that our product is highly dynamic and stable during operation;

5. The impeller is directly connected to the motor shaft, requiring no other accessories during rotation, no friction during operation, and no internal lubrication. Therefore, the output air is oil-free, pure, and environmentally friendly;

6. High performance sealing rings effectively prevent foreign objects from entering the body, effectively improving the product's service life;

7. After testing, the fan can operate smoothly and quietly for a long time, and the company provides multiple power and size options for selection;

8. The products undergo strict testing and verification before leaving the factory to ensure the efficiency of customer use.


Vacuum suction equipment high-pressure fanApplication of dual functions of blowing and suction:
1. Air suction function: screen printing machine suction, welding exhaust gas suction, weaving machine silk suction, photographic plate making, powder conveying, printing adsorption, industrial vacuum suction, vacuum dehydration, book making machine, residual cloth treatment, milk carton filling machine, tofu machinery, processing material retention, construction site, ironing machine, gas decomposition.
2. Hair blowing function: gas and heavy oil spraying, bottle washing machine drying, paper and cloth strip blowing, air knife for drying, cutting machine air cushion, animal manure fermentation explosion gas electrolyte stirring, oxygen supply for breeding ponds, convenient punching machine for taking formed products, powder conveying, incinerator waste disposal, smoke blowing and suction, car washing and drying, forced drying for printing machines, and blowing and drying after washing

Vacuum suction high-pressure fanPrecautions for use:

Before using the fan again, it is necessary to carefully check whether the voltage and frequency indicated on the product nameplate meet local requirements, and strictly operate it according to the rated voltage of the motor

Before running the fan, it is necessary to check whether there is any collision or friction between the fan blades and the casing, whether the motor is grounded, and whether the insulation is good

Before running the fan, it is necessary to check whether the rotation direction of the impeller is correct. If there are any abnormal sounds or vibrations during the trial operation, the fan should be stopped immediately, the power should be cut off for troubleshooting, and it can only be used after it is normal

When the air intake of the fan is vertically downward or upward, the pressure bearing of the motor should be replaced before use

5. The temperature of mesons transported by the fan should not exceed 80 degrees Celsius

6. Fans should not be used in areas where water is easily sprayed or directly exposed to rain

7. Fans should not be used in environments where chemical gases are corrosive, flammable, or explosive

8. The foundation or support for fastening the fan must be firm

9. The connection of the fan pipeline network should be stable, and the weight of the pipeline should not be added to the various components of the fan

When a regulating valve is installed in the pipeline, the inlet regulating valve of the fan should be turned off before shutting down, and the outlet regulating valve should be slightly opened. After the fan is running normally, gradually open the regulating valve