Vertical load pedal power car dynamometer

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The Sana Bike 1000 nuclear medicine vertical load pedal power car dynamometer produced by Ergosan GmbH in Germany is also known as: pedal power car load test dynamometer, cardiac load exercise pedal power car, electrocardiogram pedal power car load test, cardiac load test pedal power exercise, nuclear medicine discipline load exercise pedal power car, cardiac load exercise test pedal power car, horizontal exercise pedal power car, and exercise load analysis system.
Product Details

Germanyergosan GmbHproduceSana bike 1000Vertical nuclear medicineloadfootStepping powerCar dynamometer

638037844581736678473.jpg


Germanyergosan GmbHproduceSana bike 1000Vertical nuclear medicineloadfootStepping powerCar dynamometer, also known as foot dynamometerStepping powerVehicle load test dynamometer, cardiac load exercise footStepping powerCar, ECG footStepping powerVehicle load test, cardiac load test footStepping powerSports and nuclear medicine disciplinesloadSports feetStepping powerCar, heartloadSports Test FeetStepping powerCar, horizontal sports footStepping powerVehicle and Sports Load Analysis SystemWaiting for the name.

Beijing Huarui Zhida Technology Development Co., Ltd. and Beijing Huaruisen Technology Development Co., Ltd. sell: Germanyergosan GmbHproduceSanabike 1000Nuclear Medicine Vertical MovementfootStepping powerCar (Vertical Sports)footStepping powercar+Domestic sports load analysis system)It is based on a vertical structurefootStepping powerA dynamometer for automotive technology. Widely used in fields such as nuclear medicine and other special areas. Used for testing and evaluating sports nutrition metabolism, athlete physical fitness status, labor appraisal testing, sports training, rehabilitation training, etc., for example, applied in stress detection of suspected cardiovascular disorders after heart infarction or catheterization; Application of myocardial perfusion imagingstepCar sports test(abbreviationstepcar)Slightly different from traditional heart function testing,The former places greater emphasis on meeting load requirements,And safely complete the entire process;stepThe car exercise test is also applied in the load setting and safety research of myocardial perfusion load imaging.

Application features:

Comfortable exercise load device

The load generated by the flow brake with computer-controlled torque measurement has no effect on speed. This control system, together with the centrifugal block size, creates a comfortable pedaling sensation, allowing patients to fully utilize their energy storage. This mechanical device, composed of good components, operates with almost no noise, even at high speeds.

Stable structure, distinctive settings:

Adjustable seat for height1.2Mi to2.1Provide comfortable seating positions for patients between meters. The handlebars can also be adjusted. Smooth up and down movement between the handlebars and the seat is helpful for the elderly and disabled. Comfortable car seats are closely following the new development of travel car seats in the bicycle industry. Various shapes of car seats can be installed for different purposes, such as lung function tests for athletes, lung function tests for patient rehabilitation, etc. Therefore, the seat guide is equipped with standard seat fixing devices, making it easy to install various types of seats available on the market. Stable steel-Aluminum frame and transmission system can support up to160The weight in kilograms.

User friendly control center:

The computer-controlled electronic control center is located at350FfootstepInside the measuring head of the car dynamometer. The probe operation surface has control buttons and a high-definition graphic LCD display screen with background lighting. One side of its display screen is usually facing the operator of the load cell. This is why the LCD speed display screen is installed on the top of the measuring head, making it easier for patients to see the screen clearly. If this350FfootstepThe car ergometer is used for rehabilitation or training, and the measuring head can be rotated freely to see the display screen and control keys.

Widely used for cardiopulmonary diagnosis

Sana cardio 350FNuclear Medicine Vertical MovementstepCar (Vertical Sports)stepcar+Domestic sports load analysis system)FeetstepThe design of the vehicle dynamometer based on modern electronic control processors allows for pressure load testing management through all common operating modes. Regular or periodic pressure measurements can be automatically achieved through simple programming functions.

Users can complete all operational steps through the wizard on the monitor. External computer programs or graphic instrumentsThe device can be used throughRS-232orUSBInterface to access and control the dynamometer. In this situation, the footstepIt is not necessary to operate the dynamometer separately, as it can be centrally controlled through the program of the main control machine. In any mode, the LCD display displays the current load, heart rate, and force measurement status in the alphanumeric area in a graphical format.

Technical Specifications:

Power supply:230-249Fu50Hertz or115Fu60Hertz

interfaceRS-232(Electrical isolation)

size/Bottom:56kilogram/40x83centimeter

European safety standards:DIN VDE 0750-238

Braking principle: A computer-controlled eddy current brake that measures torque and is not affected by revolutions per minute.

Power range 1 until 999 Watt

Load range:20to999watt

Speed range:30-130turn/divide

Load precision DIN VDE 0750-238 (in revolution-independent region)

Display:320 x 240pixel,lcd,CCFTBacklight, the dynamometer displays character numbers, graphics, as well as user instructions, programming, and maintenance information.

Pulse measurement: Priority principle:1.electrocardiogram 2.photoelectricity,3. Heartbeat recording measurement range 35to240heartbeat

Adjustable seats: for1.2Mi to2.1The height of the patient can be adjusted arbitrarily

Adjustable handlebar: for1.2Mi to2.1Vertical or horizontal adjustment of height for patients

Performance characteristics:

High load accuracy

Rotatable probe

Using computer programs or throughRS232

Stable steel/Aluminum structure with high support capacity160Weight in kilograms

Comfortable pedaling sensation

Almost noiseless, even at high speeds

Beautiful dust-proof car body

low maintenance cost

Optional: Domestic passive exercise load electrocardiogram analysis

Technical Specifications:

True synchronization 12 Lead electrocardiogram detection and measurement analysis

Real time continuous recording of exercise electrocardiogram, without missing any electrocardiogram changes exceeding one second;

Real time online analysis and storage of full lead electrocardiogram.

All digital acquisition, RFAIncremental filtering technology, hardware module digital noise reduction, intelligent anti zero drift system, high-quality and high-definition ECG signal acquisition;

sportySTCorresponding analysis of paragraphs;

STReal time display and post-processing functions for analysis and graphics

Multi functional and multi sport preset and custom exercise plan

Report options, multiple editing methods/database statistics

Powerful database statistics function; Network compatibility.

Supports various operating systems and fully automated exercise electrocardiogram testing,Abnormal situation alert prompt

Extended feature support: exercise blood pressure, real-time thermal printer

Full digital signal electrocardiogram acquisition system

through standardsRS-232orUSBInterface, achieve voltage isolation between the computer and the device4000VData transmission and control.

By using the "isolated communication signal energy conversion" technology, various lead systems can complete ECG signals and analog-to-digital conversion without any additional power or battery support.

Sampling rate per channel1000S/sSampling accuracy 14 bit

Multiple digital filters ensure clear and accurate recording results

RFAIncremental filtering technique (ECG signal graph)Enhancer-Finite Residual Filter AlgorithmAlgorithm), hardware digital module noise reduction, can extract signals even in motion (baseline drift, muscle tremors, electromagnetic interference, etc.), thereby generating clear and detailed electrocardiograms and effectiveSTSegment analysis and evaluation. Do not change the ECG analysis, ECG measurement evaluation form, and originalQRSWave, in order to obtain valuable electrocardiograms.

Agent: Beijing Huarui Zhida Technology Development Co., Ltd

BeijingHuaruizhida Technology Development Co.Ltd.,

Beijing Huaruisen Technology Development Co., Ltd

BeijingHuaruison Technology Development Co.Ltd.,

Address: Guanghua Road, Tongzhou Industrial Development Zone, Tongzhou District, Beijing16Haofang and Zhengyuan BuildingAseat2building