E-mail
3386038725@qq.com
-
Phone
13921850971
-
Address
No. 79, Road 3, Private Industrial Park, Jianhu County
Yancheng Siyuan Water Supply and Drainage Equipment Co., Ltd
3386038725@qq.com
13921850971
No. 79, Road 3, Private Industrial Park, Jianhu County
Yancheng prefabricated pump station manufacturer integrated sewage lifting pump station
The integrated prefabricated pump station in Nanning, Guangxi has a flow rate of 183/h, a lift of 15M, and a power of 5.2KW. Our Yancheng Siyuan manufacturer has detailed the design drawings, production, installation, and commissioning
The entire equipment is assembled into one, with a high degree of integration advantage, eliminating the need for building pump rooms and valve wells, which is the origin of integration. It should be noted that the entire cylinder is buried underground, which does not affect the planting of surrounding greenery, saves land resources, reduces civil engineering workload, and saves funds. Nowadays, many integrated sewage pumping stations are also equipped with deodorization devices, effectively solving the problem of odor volatilization.
The integrated sewage lifting pump station adopts fiberglass mechanical winding technology, with a cylindrical shape. The diameter and height of the cylinder are determined according to the amount of sewage that needs to be treated in the project. There are inlet and outlet ports left on the cylinder, which are connected to the pipeline network. Sewage or rainwater flows into the fiberglass cylinder of the pump station through the municipal pipeline. The cylinder is equipped with a pressure sensor or liquid level sensor system. When the liquid level reaches a certain height, the sensor sends a signal to the control system, which controls the submersible sewage pump to start.

Daily management and control principles of integrated pumping station sewage lifting pumping station
1、 Gravity flow is generally used to pass through various structures and equipment during the operation of the process flow. A lifting pump station must be added at the pre-treatment site to lift the sewage to a certain height before it can operate according to the gravity flow method.
The function of an integrated pumping station is to lift the incoming sewage to the height required by the subsequent treatment unit, enabling it to achieve gravity flow.
An integrated pump station generally consists of a water pump, a collection tank, and a pump room.
The integrated prefabricated pump station will not cause pollution to the land, and the product volume is small enough to meet the needs of different situations; Establish an integrated prefabricated lifting pump station in the factory to collect high pollution components from the pre-treatment of sewage in the factory. After meeting the standards, they will be pressurized and transported to the sewage treatment plant; It can be used for the discharge of domestic sewage, rainwater, and industrial wastewater, as well as for water source extraction, and is a new generation of green technology products; Configure three intelligent control systems to achieve a daily sewage treatment capacity of 21600 cubic meters, and the addition of a crushing grid will effectively improve drainage efficiency;

2、 There are various types of water pumps in integrated pumping stations, with centrifugal pumps being the main ones. According to the installation method, it can be divided into dry pumps and submersible sewage pumps. Dry pumps also have vertical pumps and horizontal pumps. There are two types of submersible pumps: sewage installation and dry installation.
Integrated prefabricated pump stations can usually solve special problems caused by local construction conditions; Equipped with high-quality and high-performance submersible sewage pumps, which widely use sensors to constantly control the operation of the pumps, greatly reducing maintenance costs; The installation of integrated prefabricated pump stations is rapid, and as long as the pump pit excavation is completed, the project can be smoothly started;
3、 The function of the water collection tank is to regulate the imbalance between the incoming water volume and the pumping volume, and to avoid frequent starting of the water pump.
The layout of the water collection tank should fully consider the convenience of pump maintenance, fixed pump base maintenance, etc. (The submersible sewage pump and the collection tank should be operated separately.)
2. For balancing the inflow and outflow, the frequency modulation method is now mostly used to solve the problem, and the effect is good.
The layout of the water collection tank should take into account the convenience of cleaning and maintenance. For enclosed water collection tanks, ventilation holes and fans should be installed at the convection point.
4. The collection tank should be regularly cleaned of debris according to specific circumstances to ensure the normal operation of the water pump.
The Siyuan integrated pump station can be applied to the collection and transportation of community sewage, urban sewage, urban rainwater, and the construction and renovation of municipal sewage pipelines. The integrated prefabricated pump station will not cause pollution to the land, and the product volume is small enough to meet the needs of different situations;

Yancheng prefabricated pump station manufacturer integrated sewage lifting pump station
Integrated pumping station, sewage lifting pumping station
4、 The following principles should be considered for the operation control of the water pump unit in the collection tank
1. It is necessary to ensure that the amount of incoming water is consistent with the amount of increase, that is, how much is received and how much is increased.
2. Keep the water collection tank running at a high water level.
3. Do not start and stop the water pump too frequently.
4. There should be at least one backup pump.
5. Keep the stop and start time of each water pump in the water pump group uniform.
It can be used for the discharge of domestic sewage, rainwater, and industrial wastewater, as well as for water source extraction, and is a new generation of green technology products; The installation of integrated prefabricated pump stations is rapid, and as long as the pump pit excavation is completed, the project can be smoothly started;

Yancheng prefabricated pump station manufacturer integrated sewage lifting pump station
Integrated sewage lifting pump station manufacturers specialize in producing fiberglass integrated pump stations, integrated prefabricated pump stations, rainwater lifting integrated pump stations, integrated sewage pump stations, integrated rainwater pump stations, integrated lifting pump stations, etc. They are commonly used in municipal engineering, industry, or any other buildings that cannot directly discharge wastewater into sewage treatment systems by gravity. Among them, municipal drainage is applicable to intermediate pumping stations such as sewage pumping stations, drainage pumping stations, and confluence pumping stations.
Advantages:
Intelligent control system: No need for dedicated personnel to be on duty, GPRS remote monitoring system, knowing the operation status of the pump station anytime, anywhere
Integrated design: The components in the pump station water, as well as the overall crushing and ventilation system, are designed to be integrated as a whole.
Short construction period: You can complete excavation, backfilling, compaction, connection, leakage testing, control system installation, trial operation, final commissioning, and all processes within two weeks.
Strong anti leakage performance: The cylinder is controlled by a computer to wrap around the wellbore, with high integration in one molding process, preventing leakage and cracking.
Strength analysis testing: Each product undergoes a strength analysis test before leaving the factory to ensure its safety and reliability.
Advantages of integrated sewage lifting pump station:
Maintain safety:
Realize remote control of starting and stopping water pumps without the need for manual on-site maintenance operations, improving safety rates
Unmanned and remotely monitored, saving maintenance costs and high security performance
The pump station is equipped with safety ropes, safety grilles, toxic gas detectors, and ventilation and strong exhaust devices to ensure the personal safety of maintenance and repair personnel.
Construction safety
Strictly follow the process of excavation, backfilling, and pipeline docking, and carefully debug the system
Rich experience in deep foundation pit design and construction, solving the impact of equipment anti floating performance and geological changes on the cylinder body
Thorough construction organization design, rich experience in deep excavation, saving on-site construction time
Pre completing the main project content in the factory greatly saves on-site construction content and time, and the construction organization design is scientific, reasonable, and meticulous,