The working principle of the plug-in electromagnetic flowmeter is based on Faraday's law of electromagnetic induction. In an electromagnetic flowmeter, the conductive medium inside the measuring tube is equivalent to a conductive metal rod in Faraday's test, and the two electromagnetic coils at the upper and lower ends generate a constant magnetic field. When a conductive medium flows through, an induced voltage is generated. The induced voltage generated by measuring the two electrodes inside the pipeline. The measuring pipeline achieves electromagnetic isolation from the fluid and measuring electrodes through non-conductive lining (rubber, Teflon, etc.).
Features:
Application:
Power generation, cogeneration, and heating industries; Aviation, aerospace, shipbuilding, nuclear energy, and weapons industries; Mechanical, metallurgical, coal mining, and automobile manufacturing industries; Petroleum and chemical industries; Pharmaceutical, food, and tobacco manufacturing industries; Forest industry, agricultural reclamation, and light industry.