20000 air volume acid mistspray towerFor size, please consult Zaoqiang Runhebao Equipment Co., Ltd.
Performance Selection Table for Acid Mist Spray Tower
Specification mm |
Φ800 |
Φ1000 |
Φ1200 |
Φ1400 |
Φ1600 |
Φ1800 |
Φ2000 |
|||
Air volume m ³/h |
2000-3000 |
3000-4500 |
4500-6500 |
6500-9000 |
9000-11500 |
11500-14500 |
14500-18500 |
|||
|
through wind machine |
model |
BF4-72-3.2A |
BF4-72-3.6A |
BF4-72-6A |
BF4-72-6A |
BF4-72-6C |
BF4-72-8C |
BF4-72-10C |
||
RPM (revolutions per minute) |
2900 |
2900 |
1450 |
1600 |
1600 |
1120 |
900 |
|||
Air volume m ³/h |
2480 |
4070 |
6500 |
9010 |
11560 |
14040 |
20000 |
|||
Wind pressure pa |
128 |
150 |
120 |
137 |
115 |
120 |
130 |
|||
Motor power kw |
2.2 |
3 |
4 |
5.5 |
7.5 |
7.5 |
15 |
|||
|
liquid pump |
model |
50FS-25 |
65FS-35 |
|||||||
Motor power kw |
4 |
5.5 |
||||||||
remark |
1. The ventilation fan model is matched with a purification resistance of 70 millimeters of water column and an additional ventilation pipe resistance. Users can match other models of fans according to their actual situation 2. The water pump model is selected to match the water column with a nozzle pressure of ≥ 10 meters, and users can also match other models of water pumps |
|||||||||
The acid mist spray tower is suitable for purifying harmful acidic gases such as hydrochloric acid, sulfuric acid, nitrogen oxides (applicable to difficult to absorb nitrogen oxides) generated in electroplating acid car washing rooms and other production processes.
Purification process: The upper part of the tower is sprayed with alkaline absorption liquid, and the acidic and harmful gases entering the tower from the lower part flow in reverse with the spray liquid, passing through the blocking material and perforated plate set inside the tower. The gas-liquid contact is sufficient, and the purification effect is good.

The acid mist spray tower is managed by a dedicated person, who regularly checks whether the fan is running normally, whether the water pump is running normally, whether the liquid level is normal, whether the sodium hydroxide solution is within the specified range, and so on. If any problems are found, they should be promptly checked. The acid mist purification tower adds absorption liquid through a liquid tank, and when in use, the liquid level is raised to the level of the inlet. After the acid mist purification tower is in operation, the liquid level is raised again to the level of the inlet; During use, attention should be paid to replenishing the absorption solution. When the acid mist purification tower is working, check the water level every 8 hours and replenish the absorption solution. When using, the circulating water pump should be turned on for 2-3 minutes before turning on the blower. When stopping, the blower should be stopped for 1-2 minutes before stopping the circulating water pump. The acidity concentration of the liquid in the purification tower and the degree of gas purification in the exhaust should be regularly checked according to usage. If it is outdated, the absorption liquid in the acid mist purification tower should be replaced. Keep the area around the BSG-2 fiberglass acid mist purification tower equipment clean. This equipment should be regularly checked for blockages in the spray and packing of the purification tower, and cleaned.