Structural diagram of fiberglass spray tower desulfurization tower
Date: 2018-03-29Read: 20

fiberglassspray tower desulfurization towerIt has the characteristics of pressure resistance, corrosion resistance, long service life, light weight, strength, anti-seepage, insulation, edge, and smooth surface.

The desulfurization tower of FRP spray tower adopts the mechanism of cyclone centrifugal separation and DC centrifugal dehydration, and combines with impact foam coagulation and chemical reaction to achieve the purpose of smoke suppression, dust removal and sulfur dioxide removal.
The flue gas enters the outer cylinder in a tangent direction. Under the centrifugal force, it rotates downward along the cylinder wall. The inclined roof of the outer cylinder has the function of depressing the flue gas. The downward rotating flue gas impacts the liquid surface, splashes a lot of foam, and the flue dust is wetted and condensed by it; Dust particles settle under the action of centrifugal force and liquid adsorption force, and sulfur dioxide in the flue gas reacts with calcium hydride in the liquid as follows: SO2+Ca (OH) 2 CaSO3+H2O
Thus achieving the purpose of desulfurization, the purified flue gas enters the inner cylinder and passes through the secondary dehydrator to form a rotating upward airflow. By relying on centrifugal force, the carried moisture is thrown towards the inner cylinder wall and descends along the wall to the conical sedimentation chamber. The purified flue gas after dehydration is finally drawn out through the top pipe of the dust collector. The lower part of the conical sedimentation chamber is equipped with a chain plate ash remover, which continuously outputs the sediment. The liquid level control box of the sedimentation chamber maintains a normal liquid level through the replenishment pipe. During operation, a 50mm sized block of quicklime (CaO) should be regularly added to the dosing box to form Ca (OH) 2 and participate in the chemical reaction of desulfurization.

Structural diagram of fiberglass spray tower desulfurization tower

Size table of fiberglass spray tower desulfurization tower

boiler model
size
code name

ZTC-1

ZTC-2

ZTC-4

ZTC-6

ZTC-10

ZTC-15

ZTC-20

Processing air volume (m3/h)

4000

7000

13000

20000

32000

47000

65000

H

2930

3193

4020

4430

5072

6500

7000

800

1000

1350

1600

2000

2200

2600

¢1

310

400

550

680

850

1092

1200

B

776

976

1326

1576

1976

2176

2576

BL

1200

1500

1650

2000

2500

2800

3000

a×a

300

400

540

660

840

1100

1250

L1

2400

3000

3500

4000

5000

6000

7000