Welcome Customer !

Membership

Help

Shenzhen Xinlang Electronic Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Shenzhen Xinlang Electronic Technology Co., Ltd

  • E-mail

    fuhao@17Lp.com

  • Phone

    18576673708

  • Address

    Room 1402, Nan Guang Jie Jia Building, 3037 Shennan Middle Road, Futian District, Shenzhen, China

Contact Now

【 PMC35-1 DC Stabilized Power Supply 】 Japan Kikusui KIKUSUI Shenzhen Agent

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

【 PMC35-1 DC Stabilized Power Supply 】 KIKUSUI Shenzhen Agent from Japan is a small power supply that uses a series regulator to achieve high stability and low noise output. This low-cost universal series condenses the functions of the PMC-A series and can be used in various fields, from research and development testing equipment to testing power supplies for mass production lines. According to the Z-output voltage (18V/35V), the product lineup includes a total of 6 models.

Product Details

PMC35-1DC stabilized power supply: KIKUSUI Shenzhen agent from Japan is a small power supply that uses a series regulator to achieve high stability and low noise output. This low-cost universal series condenses the functions of the PMC-A series and can be used in various fields, from research and development testing equipment to testing power supplies for mass production lines. According to the maximum output voltage (18V/35V), the product lineup includes 6 models.

specialty

  • Comes with output switch
    The switch is a button switch with a locking mechanism, and when the output is OFF, the power supply becomes in a high impedance state.
  • The voltage and current setting knob adopts 10 transformations*1
    The output setting knob adopts a 10 turn winding type variable resistor, which can obtain stable output at high resolution.
  • Low cost popularization type
    This is a universal power supply with simplified functions and cost-effectiveness.
  • External simulation remote control*2
  • Remote sensing function attached to the load end to stabilize the output voltage*3
  • Standard installation overvoltage protection function (OVP)

1: PMC has a voltage of 10 revolutions per minute and a current of 1 revolution per minute
* 2: Only applicable to PMC-A
* 3: Only applicable to PMC-A output rated 18V and 35V series models

lineup

model Specifications
PMC18-2 0 ? 18V/0 ? 2A
PMC18-3 0 ? 18V/0 ? 3A
PMC18-5 0 ? 18V/0 ? 5A
PMC35-1 0 ? 35V/0 ? 1A
PMC35-2 0 ? 35V/0 ? 2A
PMC35-3 0 ? 35V/0 ? 3A

Specifications

* the following conditions are subject to the following unless otherwise
Net resistance load? Negative grounding? Remote sensing? After 30 minutes of warm up

Shape name output Ripple Power supply changes
CV CC CV CC CV CC
V A mVrms mArms mV mA
PMC18-2 0?18 0?2 0.5 1 1 10
PMC18-3 0?3 0.5 1 1 10
PMC18-5 0?5 0.5 2 1 5
PMC35-1 0?35 0?1 0.5 1 3 10
PMC35-2 0?2 0.5 1 3 10
PMC35-3 0?3 0.5 1 3 5
Shape name Load variation power supply Consumption of electricity appearance quality
CV CC communication about Type about
mV mA V±10% VA kg
PMC18-2 2 5 100 100 I 4
PMC18-3 4 5 160 I 5
PMC18-5 5 10 230 II 6
PMC35-1 3 5 95 I 4
PMC35-2 3 5 190 I 5
PMC35-3 4 10 240 II 6

Common Service

Output voltage 10 revolutions per minute variable
Output voltage temperature coefficient 100 ppm/ ℃(TYP)
Transition response characteristic 50 μs
Output current 1. Variable rotary linkage
Temperature coefficient of output current 200 ppm/ ℃(TYP)
Meter indication
(Green) LED)
Output voltage indication error ± (0.5% rdng+2digit)
at 23℃±5℃ (TYP )
Temperature coefficient 300ppm/℃ (TYP)
Output current indication error ± (1% rdng+5digit)
at 23℃±5℃ (TYP )
Temperature coefficient 400ppm/℃ (TYP)
Voltmeter display
Zui Da represents the truss Voltmeter
18V series: 19.99
35V series: September 1999
Ammeter
9.99
grounding Grounding positive or negative terminals
Action cycle temperature 0? C. 40 degrees Celsius
Action cycle humidity 10%rh?80%rh ( However, it is not dew.)
cooling method Natural air cooling
Grounding voltage DC±250V
Protection circuit Is the setting range of output overvoltage protection (OVP) frozen at 5%? 105%
Input Hughes / temperature Hughes
operation In line operation
(Number of possible connections=Grounding voltage ÷ Fixed output voltage, but for the same model)
Example V In the case of 250 to 35 = 7.14
Parallel operation? One control parallel operation
Dimensions zui Large Type I:107W X 124 (134) H x 270 (290) DMM
Type II:107W X 124 (134) h * 350 (370) DMM
Subsidiary products Power cable, instruction manual, Hughes

Exterior dimensions

Position: mm

外形寸法図

外形寸法図

PMC35-1DC stabilized power supply: Kikusui Shenzhen agent from Japan