Welcome Customer !

Membership

Help

Shenzhen Xinlang Electronic Technology Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Shenzhen Xinlang Electronic Technology Co., Ltd

  • E-mail

    fuhao@17Lp.com

  • Phone

    18576673708

  • Address

    Room 1402, Nan Guang Jie Jia Building, 3037 Shennan Middle Road, Futian District, Shenzhen, China

Contact Now

DESTEXIO 4 1/2 Digital Multimeter DL-2142G | China Agent

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
DeShi TEXIO 4 1/2 Digital Multimeter DL-2142G | The Chinese agent adopts VFD display with excellent visibility, which has dual display function and can display 2 measurement values at the same time. Standard USB device interface. In addition, DL-2142/DL-2142G also has USB storage function, which saves measurement data through a USB flash drive.
Product Details

Dexter TEXIO 4 1/2 digital multimeterDL-2142G|Chinese agentAdopting VFD display with excellent visibility, it has dual display function and can display 2 measurement values simultaneously. Standard USB device interface. In addition, DL-2142/DL-2142G also has USB storage function, which saves measurement data through a USB flash drive.

4 1 / 2-digit dual display? Digital multimeter
DL-2141

4 1 / 2-digit dual display? Digital multimeter
Temperature measurement? USB Log function
DL-2142

4 1 / 2-digit dual display? Digital multimeter
(Temperature measurement? USB Equipped with RAM function GP-IB Standard equipment)
DL-2142G











DL-2140 Series is a 4 / 2-digit digital multimeter of 50000 counts. VFD( It has excellent visibility by adopting fluorescent display tube. In addition, it is possible to display two measurement values of the input signal simultaneously because it is a dual display. For remote control USB Device port is standard. And DL-2142/DL-2142G To USB Equipped with log function zui About 5000 records USB It is possible to store it in memory. Development? Inexpensive price is easy to use in the design and education site.

specialty

Full scale 50000 count 4 1 / 2-digit digital multimeter
◆ DCV Accuracy 0.02%
Two measurements of the input signal DC Turn the voltage on one side AC Simultaneous voltage display
◆  VFD( Realization of excellent visibility in fluorescent display tube
◆  USB Remote control enabled
True RMS measurements
Wide voltage range mV~1000V Range DC Current 500 μA~10A Range
Lazy mode (REL) setting off residual components before measurement
Compare mode equipment to determine the range of measurement and out of range (HI / Lo / pass)
Measurement value zui Large zui Hold small MIN/MAX Mode equipment
◆  zui About 5000 records USB Record in memory USB Log function※1
◆  DL-2142G は GP-IB Interface
※1:DL-2141 Except

freeze-frame

■ General service

Service conditions:

temperature

23℃±5℃

humidity

<80%RH、75%RH (10M When measuring resistance above Ω

Action environment: (0-50 ℃)

temperature range

0℃~35℃、

Relative humidity:<80% RH

>35℃、

Relative humidity:<70% RH

Indoor use only

height

2000m not yet

Dyeing degree

2

Storage temperature: -10~70 ° C? C

Operating temperature

0℃~35℃

Relative humidity:<90% RH

>35℃

Relative humidity:<80% RH

Power supply voltage

AC100V/120/220/240V ±10% 50/60Hz

Consumption of electricity

About 15 VA

dimension

265(W) x 107(H) x 302(D) mm

quality

About 2.9 kg


■ DC Voltage

Range

resolution

Full scale

Accuracy

Entering into resistance

(1 year 23 ℃± 5 ℃)

500mV

10μV

510.00

0.02%+4

10M Or G Omega

5 V

100μV

5.1000

10M Or G Omega

50 V

1mV

51.000

11.1MΩ

500 V

10mV

510.00

10.1MΩ

1000 V

100mV

1020.0

10MΩ

If the input voltage exceeds the full scale of the selected range, the display is - OL- ( Overload.
Input voltage is 1000 V The buzzer sound is over.
* 1000V Protection of peak voltage V .


■ DC current

Range

resolution

Full scale

Accuracy

Shunt resistance

Burden of voltage

(1 year 23 ℃± 5 ℃)

500μA

10nA

510.00

0.05%+5

100Ω

The maximum voltage is 0.06V

5mA

100nA

5.1000

0.05%+4

100Ω

Zui Big 0.6V

50mA

1uA

51.000

0.05%+4

The maximum voltage is 0.14V

500mA

10uA

510.00

0.10%+4

Zui Big 1.4V

5A

100uA

5.1000

0.25%+5

10mΩ

Zui Big 0.5V

10A

1mA

12.000

0.25%+5

10mΩ

Zui Big 0.8V

* 500μA~500mA Range is V Limit and A There is protection by Hughes.
* 10A Range A There is protection by Hughes.
* OL-( Overload.
Rated A Input. Input is A Buzzer sounds when it exceeds.


■ AC Voltage

Range

resolution

Full scale

Accuracy (1 year 23 ℃± 5 ℃) [1]

30-50Hz

50-10kHz

10k-30kHz

30k-100kHz

500mV

10μV

510.00

1.00%+40

0.50%+40

2.00%+60

3.00%+120

5V

100μV

5.1000

1.00%+20

0.35%+15

1.00%+20

3.00%+50

50V

1mV

51.000

1.00%+20

0.35%+15

1.00%+20

3.00%+50

500V

10mV

510.00

x

0.5%+15

1.00%+20[2]

3.00%+50[2]

750V

100mV

765.0

x

0.5%+15

X

x

[1] rated is 5% or more of the range by sine wave input.
[2] input voltage is 300 Vrms .
* the body voltage is 750 V Input voltage is 750 V The buzzer sound is over.
* 1000V Protection of peak voltage V .
* AC Combined RMS Measures are Vdc .


■ AC current

Range

resolution

Full scale

Accuracy (1 year 23 ℃± 5 ℃) [1] [2]

Burden of voltage

30-50Hz

50-2kHz

2k-5kHz

5k-20kHz

500μA

10nA

510.00

1.50%+50

0.50%+40

1.50%+50

3.00%+75

The maximum voltage is 0.06V

5mA

100nA

5.1000

1.50%+40

0.50%+20

1.50%+40

3.00%+60

Zui Big 0.6V

50mA

1μA

51.000

1.50%+40

0.50%+20

1.50%+40

3.00%+60

The maximum voltage is 0.14V

500mA

10μA

510.00

1.50%+40

0.50%+20

1.50%+40

3.00%+60[3]

Zui Big 1.4V

5A

100μA

5.1000

2.0%+40

0.50%+30

×

×

Zui Big 0.5V

10A

1mA

12.000

2.0%+40

0.50%+30

×

×

Zui Big 0.8V

[1]500μA Range is 35 μA The rated value above. 5mA~10A Range is 5% or more rated.
[2] input current is μArms .
[3] Input current (5kHz~20kHz)<330mArms
Rated A Guarantee. 10A Buzzer sounds when it exceeds.


Resistance

resist

resolution

Full scale

Test current

Accuracy

(1 year 23 ℃± 5) [3]

500Ω

10mΩ

510.00

0.83mA

0.1%+5 [1]

5kΩ

100mΩ

5.1000

0.83mA

0.1%+3 [1]

50kΩ

51.000

83μA

0.1%+3

500kΩ

10Ω

510.00

8.3μA

0.1%+3

5MΩ

100Ω

5.1000

830nA

0.1%+3

50MΩ

1kΩ

51.000

560nA

0.3%+3[2]

[1] REL Function. REL If the function is not used, an error of 0.2 ohms is increased.
[2] 20 M The measurement of. Omega. Becomes 0.8% + 3.
[3] 500k For measuring resistance greater than. Omega., use a shield lead to remove interference of noise.
* open M In the range of V、50M The range is approximately 5.5 V Voltage.
500 in full range V Peak input protection


Diode

Range

resolution

Full scale

Test current

Accuracy (1 year 23 ℃± 5 ℃)

5V

100uV

5.1000

0.83mA

0.05%+5

Input protection 500 V Peak. Open circuit voltage: About V.


Capacitance

Range

resolution

Full scale

Test current

Accuracy

(1 year 23 ℃± 5 ℃) [1]

5nF: 0.5nF~1nF

0.001nF

5.100

8.3μA

2.0%+20

5nF: 1nF~5nF

2.0%+10

50nF: 5nF~10nF

0.01nF

51.00

8.3μA

2.0%+30

50nF: 10nF~50nF

2.0%+10

500nF

0.1nF

510.0

83μA

2.0%+4

5μF

1nF

5.100

0.56mA

50μF

10nF

51.00

0.83mA

[1] 5nF ~ 50μF The input range should be 10% rated.
Full range 500 V Peak input protection


■ Number of cycles

Measurement range

Accuracy (1 year 23 ℃± 5 ℃)

10Hz ~ 500Hz

0.01%+5

500Hz ~ 500kHz

0.01%+3

500kHz ~ 1MHz

0.01%+5

* AC + DC You cannot measure the frequency.
1000 in full range V Peak input protection


Voltage measurement sensitivity

Range

Zui small sensitivity (RMS sine wave)

10Hz~100kHz

100kHz~500kHz

500 mV

35 mV

200 mV

5 V

0.25 V

0.5 V

50 V

2.5 V

5 V

500 V

25 V

uncal

750 V

50 V

uncal


Current measurement sensitivity

Range

Zui small sensitivity (RMS sine wave)

30Hz~20kHz

500μA

35μA

5mA

0.25mA

50mA

2.5mA

500mA

25mA

5A

0.25A (<2kHz)

10A

2.5A (<2kHz)


■ Temperature (DL-2142/DL-2142G)

Sensor

Type

Range

resolution

Accuracy (1 year 23 ℃± 5 ℃)

Thermoelectric pair

J、K、T

-200 ~ +300°C

0.1°C

2℃

Note: temperature specification contains no sense error.


■ Subsidiary products

Power cord

1 book

CD-ROM

Instruction manual USB Driver others

Test lead

1 group (red? GTL-207

USB Cable

1 GTL-246

Dexter TEXIO 4 1/2 digital multimeterDL-2142G|Chinese agent

Dexter TEXIO 4 1/2 digital multimeterDL-2142G|Chinese agent