ADL400N bidirectional metering new energy meter photovoltaic energy storage UL/MID
ADL400N-CT/D16 digital display instrument 120A connectedofModel Description

2.ADL400N-CT/D16 digital display instrument 120A connectedList of functions

3.Technical Specifications


4. External dimensions
4.1 Instrument dimensions

4.2Transformer size
4.2.1 120A/40mAmutual inductor

5. Main functional features
5.1 Measurement Function
Capable of measuring all electrical parameters including voltage U, current I, active power P, reactive power Q, apparent power S, power factor PF, and frequency. Voltage U is rounded to 1 decimal place, frequency F is rounded to 2 decimal places, current I is rounded to 2 decimal places, and power P is rounded to 3 decimal places. For example: U=220.1V, f=49.98Hz, I=1.99A, P=0.439kW. The instrument also provides high-speed response registers for the above electrical parameters, as described in Chapter 9 Communication Instructions.
5.2 The metering function can measure the current combination of active energy, forward active energy, reverse active energy, forward reactive energy, and reverse reactive energy.
6. Communication instructions
The RS485 communication interface of the instrument supports MODBUS-RTU communication protocol, and the baud rate of the communication port can be set between 1200bps, 2400 bps, 4800bps, 9600bps, 19200 bps, and 38400 bps, with no checksum. The RS485 communication port of the instrument requires the use of shielded twisted pair cables for connection. When wiring, the layout of the entire network should be considered, such as the length and direction of communication cables, the position of the upper computer, the matching resistance at the end of the network, communication converters, network scalability, network coverage range, and electromagnetic interference in the environment, all of which need to be comprehensively considered.
Note: 1. Construction must strictly follow the requirements in wiring engineering;
2. For instruments that do not require communication temporarily, they should be connected to the RS-485 network for diagnosis and testing purposes;
3. When connecting RS-485 cables, try to use dual color twisted pair cables, and connect all 485 communication ports with the same color on the "A" end and another color on the "B" end.
4. The RS-485 bus (from the communication port of the upper computer to any connected instrument terminal communication port) shall not exceed 1000 meters in length.
ADL400N bidirectional metering new energy meter photovoltaic energy storage UL/MID