Air cooled COD digester

NegotiableUpdate on 02/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The SH-12 air-cooled COD digester adopts microcomputer technology for timed control of the heating electric furnace, which can simultaneously heat 12 specially designed heating bottles. To achieve the goals of energy conservation, reducing power load, and improving efficiency.
Product Details

SH-12Air cooled COD digesterThe national HJ828-2017 standard analysis method standardizes the development of chemical oxygen demand (COD) for water quality(CrThe measurement steps strictly specify the conditions and indicators of the method, such as heating and digestion time, solution acidity, oxidant and catalyst dosage. It is obvious that the water quality COD(CrThere are strict conditions for the measurement, and any operation that violates these conditions will affect the accuracy of the measurement.

COD(CrThe constant temperature heater follows the basic principles of international standards (ISO) and the new national standard HJ828-2017, ensuring the digestion operation of reflux heating and micro boiling for 2 hours. The preparation and addition of reagent solutions are consistent with the HJ environmental standard method, ensuring reliable and accurate analysis results.

The instrument adopts microcomputer technology for timed control of the heating electric furnace, which can simultaneously heat 12 specially made cylindrical bottles. To achieve the goals of energy conservation, reducing power load, and improving efficiency.

The instrument adopts a glass burr reflux tube instead of a spherical reflux tube, and uses air cooling technology instead of tap water cooling, which can save water and standardize the instrument.

The chemical solution preparation, operation, and COD calculation of the instrument shall comply with the new standard HJ828-2017 and be below 50%mg/LThe accuracy of COD water samples can be improved by diluting titrants and oxidants, exceeding 700mg/LThe COD water sample can be measured by diluting it proportionally.

SH-12Air cooled COD digesterTechnical specifications

Compliant with national standard: New standard HJ828-2017

Measurement range: 5-700mg/L; Determination after dilution of 700mg/L to 10000 mg/L water sample

Dissolving time: 1 minute to 2 hours and 30 minutes (users can choose their own heating time)

Measurement error: The relative standard deviation of potassium hydrogen phthalate standard solution (500mg/L) shall not exceed 5.0%;

The relative standard deviation of industrial organic wastewater (500mg/L) is not more than 8.0%

Environmental temperature: ≤ 40 ℃

Cooling method: The upper inserted burr condenser tube is water-cooled with dual fans for dual cooling.

Number of Dissolved Samples:8 specially made cylindrical bottlesHeat and digest in two rows simultaneously

Heating power: 1600W(AC 220V,50HZ)

Heating table: stainless steelHeating table top, overall structure of heating plate, overhead heating, easy to remove for replacement and maintenance.