Alicat gas mass flowmeter M/MB/MWB portable flowmeter MS corrosion-resistant gas flowmeter WHISPER low-pressure loss gas mass flowmeter from the United States

NegotiableUpdate on 05/02
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Alicat gas mass flowmeter M-500SLPM-D portable flowmeter MB-5SLPM-D air flowmeter M-1000SLPM-D-DB9/5MM-250SLPM-D/CM, GAS: AIR flow sensor M-1000SLPM-D/5M, GAS: AIRMS-500SCCM-D-X explosion-proof gas mass flowmeter MS-100SCCM-D corrosion-resistant gas flowmeter M-50SLPM-D/5MMWB-40SLPM-D low pressure loss portable gas mass flowmeter MBS-100SLPM-D/5M corrosion-resistant high-precision portable gas mass flowmeter

Product Details

Whisper-Med-M-straight-color_1200.jpg

Erikat ALICAT Gas Mass Flow Meter M/MS/MB/MW/MWB/MQ/MQB Erikat ALICAT Gas Mass Flow Controller MC/MCR/MCS/MCW/MCQ/MCRQ



M-50SCCM-D_gas air.jpg

The American Erikat ALICAT mass flow meter and ALICAT mass flow controller help improve process control and calibration efficiency. Ericat offers multiple configuration methods to customize gas flow meters or controllers suitable for low pressure loss, high pressure environments, or corrosive applications. Standard features include real-time reading, rapid valve action, and multiple gas calibrations. Ericat offers a wide range of models specifically customized for flow rates up to 5000 slpm or as low as 2.5 s µ lm/0.0025 sccm.


gas-mass-flow-meter1.jpg

Alicat flow analysis controller from the United States, focusing on quality flow and pressure analysis and control technology.
From gas monitoring and analysis to industrial process control, Alicat is not just one step ahead!
The Mass Flow Meter SeriesM series gas mass flow meters are suitable for many flow measurement applications, with a variety of models that can measure flow rates up to 5000 slpm or as low as 0.0025 sccm.
If the pipeline pressure is high (145-305 PSI), please choose the MQ series high-pressure gas mass flowmeter.

IMG_2795.jpg

Common models of ALICAT gas mass flowmeter
M Series Standard Gas Flow Meters
MQ Series High Pressure Gas Flow Meters
The MW Series Low Pressure Drop MetersMW series low-pressure loss gas mass flowmeter is suitable for low-pressure loss applications and can also shorten the aerodynamic response time under flow rate conditions of 50ccccm or lower.
BIO Series Bioreactor Gas Flow Meters MB Series Battery Powered Mass Flow Meters
The MBQ Series High Pressure Battery Powered MetersMBQ series portable high-pressure gas mass flow meter is suitable for high-pressure (145-305 PSI) pipelines.
The MWB Series Low Pressure Drop Battery Meters are portable low pressure loss gas mass flow meters suitable for low pressure loss applications.
Each series of mass flow meters mentioned above adopts a portable configuration powered by batteries: the MB series portable gas mass flow meters are suitable for typical application environments.

IMG_2794.jpgIMG_0118.jpg

IMG_2823.jpg


L1.png

liquid-flow-meter.jpg

home-graphic.jpg

A2.png

A3.png

A4.png

A1.png





M-series gas mass flow meters M-1000SLPM-D, M-2000SLPM-D, M-3000SLPM-D, M-4000SLPM-D, M-5000SLPM-D
Real time high-precision multi-dimensional flow measurement

M-4000SLPM-D.jpg
The M-series gas mass flowmeter simultaneously measures mass flow rate, volume flow rate, pipeline pressure, and pipeline temperature in real-time. It has a wide range of available flow ranges and is equipped with multiple gas calibrations, making it a star device in your laboratory.
Accurate. Flow measurement has NIST traceable accuracy and is suitable for various gases as low as 1/200th of full scale. It can also be measured using COMPOSER ™ Customize your own gas composition with the gas editor.
Easy to use. As long as you turn on the flow meter, it can display real-time flow, pressure, and temperature readings in the selected process equipment.
connect. The Ericat M series gas mass flowmeter defaults to using both digital and analog communication methods; When ordering, Ethernet/IP, EtherCAT, DeviceNet, Profibus, or Modbus (RTU and TCP/IP) communication can be selected for easy integration with your digital industrial or laboratory network.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.

M1.png

M2.png

performance
Available range: maximum 0-5000 slpm; Minimum 0-0.5 sccm/0-500 s μ lm (For the standard range, please refer to the part number label)
Adjustable ratio: 200:1 (M series) or 100:1 (MS series)
Standard accuracy (NIST traceable): ± (0.8% reading+0.2% full-scale)
High precision (optional, NIST traceable): ± (0.4% reading+0.2% full-scale)
Repeatability: 0.2% full scale
Standard controller response time constant: 5-10ms
No preheating time required

M3.PNG
working conditions
Compatible gases: 98 (MB series) or 130 (MBS series) preset optional gases; Customize other mixed gases using COMPOSER gas editor
Working temperature: -10 ° C to+60 ° C
Maximum internal pressure (static): 145 psi (160 psi)
Maximum differential pressure (inlet to outlet): 75 psid
Pressure tolerance: 175 psi (190 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)

M4.PNG
M5.PNG

Packing List
M-series gas mass flowmeter (power supply needs to be ordered separately)
NIST Traceable Calibration Certificate
Ericat Operating Manual
Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables
BB3 and BB9 multi-point junction boxes
Flow Vision software
M6.PNG
M7.PNG

Product application:
Filter performance testing
Use a pressure controller to maintain a certain differential pressure in the filter, and determine the performance of the filter by comparing the flow rate and pressure loss curve. The flow reading displayed by the gas mass flowmeter is the flow required to overcome pressure loss.
Quick leak testing
Accurately measure the pressure of the target device, using the Ericat PC3 series pressure controller equipped with remote sensing ports to control the pressure of the target device and determine whether there is a leak. This scheme eliminates the pressure loss generated during the process of measuring leakage rate with a response speed of 5ms using a mass flow meter.



M8.PNG


M9.PNG

Erikat M-series gas mass flow meters are suitable for non corrosive gases, commonly used models:

M-0.5SCCM-D
M-1SCCM-D
M-2SCCM-D
M-5SCCM-D
M-10SCCM-D
M-20SCCM-D
M-50SCCM-D
M-100SCCM-D
M-200SCCM-D
M-500SCCM-D
M-1SLPM-D
M-2SLPM-D
M-5SLPM-D
M-10SLPM-D
M-20SLPM-D
M-50SLPM-D
M-100SLPM-D
M-250SLPM-D
M-500SLPM-D
M-1000SLPM-D
M-1500SLPM-D
M-2000SLPM-D
M-3000SLPM-D
M-5000SLPM-D



MS-100SLM-D.PNG
The Ericat MS series gas mass flowmeter is suitable for corrosive gases.


ms1.PNG

ms2.PNG

ms3.PNG

MS-0.5SCCM-D
MS-1SCCM-D
MS-2SCCM-D
MS-5SCCM-D
MS-10SCCM-D
MS-20SCCM-D
MS-50SCCM-D
MS-100SCCM-D
MS-200SCCM-D

MS-500SCCM-D

MS-1SLPM-D
MS-2SLPM-D
MS-5SLPM-D
MS-10SLPM-D
MS-20SLPM-D
MS-50SLPM-D
MS-100SLPM-D
MS-250SLPM-D

MS-500SLPM-D


MS-1000SLPM-D
MS-1500SLPM-D
MS-2000SLPM-D
MS-3000SLPM-D
MS-5000SLPM-D


ms4.PNG

ms5.PNG

ms6.PNG

ms7.PNG

ms8.PNG

ms9.PNG
MW series low-pressure loss gas mass flowmeter, high-precision multi-element flow measurement (with minimal system impact)

MW-TFT.PNG
The Whisper series low-pressure loss gas mass flowmeter is highly suitable for measuring mass flow and volumetric flow. Low pressure loss will ensure minimal system impact and enable flow measurement under conditions close to atmospheric pressure or almost no system pressure. This flowmeter has an extremely wide flow range and is equipped with multiple gas calibrations, so it can work for a long time.
Accurate. Flow measurement has NIST traceable accuracy and is suitable for various gases as low as 1/200th of full scale. It can also be measured using COMPOSER ™ Customize your own gas composition with the gas editor.
Easy to use. As long as you turn on the flow meter, it can display real-time flow, pressure, and temperature readings in the selected process equipment.
connect. The Ericat gas mass flowmeter defaults to using both digital and analog communication methods; When ordering, Ethernet/IP, EtherCAT, DeviceNet, Profibus, or Modbus (RTU and TCP/IP) communication can be selected for easy integration with your digital industrial or laboratory network.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
performance
mw1.PNG

mw2.PNG
Available range: maximum 0-1000 slpm; Minimum 0-0.5 sccm/0-500 s μ lm (for the standard range, please refer to the part number label)
Adjustable ratio: 200:1
Standard accuracy (NIST traceable): ± (0.8% reading+0.2% full-scale)
High precision (optional, NIST traceable): ± (0.4% reading+0.2% full-scale)
Repeatability: 0.2% full scale
Standard controller response time constant: 5-10ms
No preheating time required
working conditions
mw3.PNG
Compatible gases: 98 preset optional gas calibrations; Customize other mixed gases using COMPOSER gas editor
Working temperature: -10 ° C to+60 ° C
Maximum internal pressure (static): 45 psi (60 psi)
Maximum differential pressure (inlet to outlet): 15 psid
Pressure tolerance: 175 psi (190 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)
Packing List
mw4.PNG
MW series low-pressure loss gas mass flowmeter (power supply needs to be ordered separately)
NIST Traceable Calibration Certificate
Ericat Operating Manual
Accessories (to be ordered separately)
mw5.PNG
Process port connectors and filters
power supply
Communication cables and conversion cables
BB3 and BB9 multi-point junction boxes
Flow Vision software
mw6.PNG
Product application:
Monitoring and recording of bioreactor output
It is necessary to compare the mass of gas added to the bioreactor with the mass of gas already removed, which is helpful for applications such as methane production or hydrogenation processes. If degassing occurs under atmospheric conditions, the extremely low pressure loss of the Ericat gas mass flowmeter will not induce back pressure when quantifying the degassing mass.

mw7.PNG

ALICAT portable gas flowmeter
Alicat portable gas flow meters can quickly and easily complete system inspections, calibrations, and audits. All portable flow meters have laboratory level accuracy, can provide dynamic readings, and can be updated 1000 times per second.
0.6% reading accuracy in most flow meters
4 ms response time
No warm-up
Four process variables
Built in display
Industrial agreement
Pressure compensation
temperature compensation
Wide dynamic flow range
The AFS series portable gas flow calibrator is a mobile calibrator, characterized by the highest calibration accuracy, humidity compensation, and the ability to take average readings and record onboard data.
The FP-25 atmospheric sampling flow calibrator is an AFS that is not affected by weather and is specifically designed for calibrating outdoor atmospheric particulate matter (PM) samplers.
The MB series portable gas mass flowmeter is suitable for a variety of flow measurement applications and models, and can measure flow rates up to 5000 slpm or as low as 0.0025 sccm.
If the pipeline pressure is high (145-305 PSI), please choose the MBQ series portable high-pressure gas mass flowmeter.
The MWB series portable low-pressure loss gas mass flowmeter is suitable for low-pressure loss application environments and can also shorten the aerodynamic response time under flow conditions of 50ccccm or lower.
The PCU series portable gas flow calibrator is a portable mobile calibrator that combines three types of flow meters and has an extremely wide range of available ranges. When the range of a single flowmeter is insufficient to meet your calibration needs, please choose PCU series products.


MW-TFT-whisper.jpg

MWB-Display.jpg

MB便携式气体流量计.jpg

MQ.jpg

MWB-TFT-P1010632_1200.jpg


The Ericat MW series low-pressure loss gas mass flowmeter is suitable for non corrosive gases, commonly used models:
MW-0.5SCCM-D
MW-1SCCM-D
MW-2SCCM-D
MW-5SCCM-D
MW-10SCCM-D
MW-20SCCM-D
MW-50SCCM-D
MW-100SCCM-D
MW-200SCCM-D
MW-500SCCM-D
MW-1SLPM-D
MW-2SLPM-D
MW-5SLPM-D
MW-10SLPM-D
MW-20SLPM-D
MW-40SLPM-D
MW-50SLPM-D
MW-100SLPM-D
MW-250SLPM-D
MW-500SLPM-D
MW-1000SLPM-D
mq.PNG
MQ series high-pressure gas mass flowmeter, real-time multi-element flow measurement for high-pressure applications
This multifunctional MQ series high-pressure gas mass flow meter can shorten the time required for calibration or verification of operating flow under high pressure (160-320 psi) conditions, and can also measure mass flow rate, volume flow rate, pipeline pressure, and pipeline temperature in real-time simultaneously.
Accurate. Flow measurement has NIST traceable accuracy and is suitable for various gases as low as 1/50th of full scale. It can also be measured using COMPOSER ™ Customize your own gas composition with the gas editor.
Easy to use. As long as you turn on the gas mass flow meter, it can display real-time flow, pressure, and temperature readings in the selected process equipment.
connect. The Ericat gas mass flowmeter defaults to using both digital and analog communication methods; When ordering, Ethernet/IP, EtherCAT, DeviceNet, Profibus, or Modbus (RTU and TCP/IP) communication can be selected for easy integration with your digital industrial or laboratory network.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
mq1.PNG


mq2.PNG
performance
Available range: maximum 0-5000 slpm; Minimum 0-10 sccm (see part number label for standard range)
Adjustable ratio: 50:1
Calibration accuracy (NIST traceable): ± 2% of full scale
Repeatability: 0.2% full scale
Standard controller response time constant: 5-10ms
No preheating time required
mq3.PNG
working conditions
Compatible gases: 98 (MQ series) or 130 (MQS series) preset optional gases; Customize other mixed gases using COMPOSER gas editor
Working temperature: -10 ° C to+60 ° C
Maximum internal pressure (static): 305 psi (320 psi)
Maximum differential pressure (inlet to outlet): 100 psid
Pressure tolerance: 400 psi (415 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)
mq4.PNG
Packing List
MQ series high-pressure gas mass flowmeter (power supply needs to be ordered separately)
NIST Traceable Calibration Certificate
Ericat Operating Manual
mq5.PNG
Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables
BB3 and BB9 multi-point junction boxes
Flow Vision software
mq6.PNG
Model variant
Corrosive gas models (MQS series, see below)
Portable models equipped with rechargeable batteries (MBQ series)
Additionally:
Standard configuration model, up to 160 psi (M series)
Low pressure loss model, up to 60 psi (MW series)
mq7.PNG
Corrosive gases (MQS series)
In the MQ series high-pressure gas mass flowmeter, there is also an "S" series configuration (i.e. MS series) suitable for corrosive gases to choose from. In this configuration, we upgraded the main body of the flow meter and sensors to 316L stainless steel material, and upgraded the elastic material to FFKM.
Structural Options
Communication protocols (analog communication, RS-232, RS-485, DeviceNet, EtherCAT, Ethernet/IP, Modbus RTU or TCP/IP, PROFIBUS)
Display screen (monochrome or color, built-in or panel mounted)
Process connectors (NPT, SAE, AN, BSPP/G, welded compression or VCR/VCO joints)
Elastic materials (fluororubber, FFKM, EPDM, silicone resin)
Performance Options
Flow accumulator
Custom calibration
mq8.PNG
MQ, MQS Ericat MQ series high-pressure gas mass flow meters are suitable for non corrosive gases and commonly used models
MQ-10SCCM-D
MQ-20SCCM-D
MQ-50SCCM-D
MQ-100SCCM-D
MQ-200SCCM-D
MQ-500SCCM-D
MQ-1SLPM-D
MQ-2SLPM-D
MQ-5SLPM-D
MQ-10SLPM-D
MQ-20SLPM-D
MQ-50SLPM-D
MQ-100SLPM-D
MQ-250SLPM-D
MQ-500SLPM-D
MQ-1000SLPM-D
MQ-1500SLPM-D
MQ-2000SLPM-D
MQ-3000SLPM-D
MQ-5000SLPM-D
The Ericat MQS series high-pressure gas mass flowmeter is suitable for corrosive gases.
MQS-10SCCM-D
MQS-20SCCM-D
MQS-50SCCM-D
MQS-100SCCM-D
MQS-200SCCM-D
MQS-500SCCM-D
MQS-1SLPM-D
MQS-2SLPM-D
MQS-5SLPM-D
MQS-10SLPM-D
MQS-20SLPM-D
MQS-50SLPM-D
MQS-100SLPM-D
MQS-250SLPM-D
MQS-500SLPM-D
MQS-1000SLPM-D
MQS-1500SLPM-D
MQS-2000SLPM-D
MQS-3000SLPM-D
MQS-5000SLPM-D
MB-10SCCM.PNG
MB series portable gas mass flowmeter can complete laboratory level flow calibration anytime, anywhere
Stopping the operation process for verification or calibration is very unfortunate but necessary. The Ericat MB series portable gas mass flow meter makes this program simpler as it reduces downtime and process interruption time. This instrument has a wide flow range and can provide instantaneous real-time readings of multiple gases, allowing you to quickly stop and start.
Accurate. Flow calibration has NIST traceable accuracy and is suitable for various gases as low as 1/200th of full scale. COMPOSER can also be used ™ Customize your own gas composition with the gas editor.
Efficient. As long as you open the MB series portable gas mass flowmeter, it can display real-time flow, pressure, and temperature readings in your selected process equipment.
Durable. The MB series portable gas mass flowmeter is designed for easy portability and can withstand the impact of falling.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
mb0.PNG
performance

mb1.PNG

mb2.PNG
Available range: maximum 0-5000 slpm; Minimum 0-0.5 sccm/0-500 s μ lm (for the standard range, please refer to the part number label)
Adjustable ratio: 200:1 (MB series) or 100:1 (MBS series)
Standard accuracy (NIST traceable): ± (0.8% reading+0.2% full-scale)
High precision (optional, NIST traceable): ± (0.4% reading+0.2% full-scale)
Repeatability: 0.2% full scale
Standard controller response time constant: 5-10ms
No preheating time required
mb3.PNG
working conditions
Compatible gases: 98 (MB series) or 130 (MBS series) preset optional gases; Customize other mixed gases using COMPOSER gas editor
Working temperature: -10 ° C to+60 ° C
Maximum internal pressure (static): 145 psi (160 psi)
Maximum differential pressure (inlet to outlet): 75 psid
Pressure tolerance: 175 psi (190 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)
mb4.PNG

Packing List
MB series portable gas mass flowmeter (fully charged)
Micro USB charging cable and AC wall mounted adapter
NIST Traceable Calibration Certificate
Ericat Operating Manual
mb5.PNG
Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables
BB3 and BB9 multi-point junction boxes
Flow Vision software
mb6.PNG
Model variant
Low pressure loss model, up to 60 psi (MWB series)
High pressure model, 160-320 psi (MBQ series)
Corrosive gas models (MBS series, see below)
Corrosive gas (MS series)

mb7.PNG
In the MB series portable gas mass flow meter, there is also the "S" series configuration (i.e. MBS series) suitable for corrosive gases to choose from. In this configuration, we upgraded the main body of the flow meter and sensors to 316L stainless steel material, and upgraded the elastic material to FFKM.
Structural Options
Communication protocols (analog communication, RS-232, RS-485, DeviceNet, EtherCAT, Ethernet/IP, Modbus RTU or TCP/IP, PROFIBUS)
Display screen (monochrome or color, built-in or panel mounted)
Process connectors (NPT, SAE, AN, BSPP/G, welded compression or VCR/VCO joints)
Elastic materials (fluororubber, FFKM, EPDM, silicone resin)
mb8.PNG

mb9.PNG
Performance Options
Flow accumulator
High precision or custom calibration
MB, MBS Ericat MB series portable gas mass flowmeter is suitable for non corrosive gases, commonly used models:
MB-0.5SCCM-D
MB-1SCCM-D
MB-2SCCM-D
MB-5SCCM-D
MB-10SCCM-D
MB-20SCCM-D
MB-50SCCM-D
MB-100SCCM-D
MB-200SCCM-D
MB-500SCCM-D
MB-1SLPM-D
MB-2SLPM-D
MB-5SLPM-D
MB-10SLPM-D
MB-20SLPM-D
MB-50SLPM-D
MB-100SLPM-D
MB-250SLPM-D
MB-500SLPM-D
MB-1000SLPM-D
MB-1500SLPM-D
MB-2000SLPM-D
MB-3000SLPM-D
MB-5000SLPM-D

mbs1.PNG

mbs2.PNG

mbs3.PNG
The Ericat MBS series portable gas mass flowmeter is suitable for corrosive gases.
MBS-0.5SCCM-D
MBS-1SCCM-D
MBS-2SCCM-D
MBS-5SCCM-D
MBS-10SCCM-D
MBS-20SCCM-D
MBS-50SCCM-D
MBS-100SCCM-D
MBS-200SCCM-D
MBS-500SCCM-D
MBS-1SLPM-D
MBS-2SLPM-D
MBS-5SLPM-D
MBS-10SLPM-D
MBS-20SLPM-D
MBS-50SLPM-D
MBS-100SLPM-D
MBS-250SLPM-D
MBS-500SLPM-D
MBS-1000SLPM-D
MBS-1500SLPM-D
MBS-2000SLPM-D
MBS-3000SLPM-D
MBS-5000SLPM-D
Product application:
Internal flow calibration of gas chromatograph (MB series)
The MB series portable gas mass flowmeter is used for real-time verification of whether the flow process is normal. Simultaneously display flow and pressure readings to improve calibration efficiency. Accurate and reproducible measurement results exceed the reporting standards of external calibration personnel.
WISHPER2.PNG
MWB series portable low-pressure loss gas mass flowmeter
Complete traffic measurement anytime, anywhere (with minimal impact on the system)
The Whisper series portable low pressure loss gas mass flowmeter is highly suitable for calibrating mass flow and volume flow. Low pressure loss will ensure minimal impact on the system, enabling flow measurement under conditions close to atmospheric pressure or almost no system pressure.
Accurate. Flow calibration has NIST traceable accuracy and is suitable for various gases as low as 1/200th of full scale. COMPOSER can also be used ™ Customize your own gas composition with the gas editor.
Efficient. As long as you turn on the MWB device, it can display real-time flow, pressure, and temperature readings from the selected process equipment.
Durable. The MWB series portable low-pressure loss gas mass flowmeter is designed for easy portability and can resist the impact of falling.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
mwb1.PNG

mwb2.PNG
performance
Available range: maximum 0-1000 slpm; Minimum 0-0.5 sccm/0-500 s μ lm (for the standard range, please refer to the part number label)
Adjustable ratio: 200:1
Standard accuracy (NIST traceable): ± (0.8% reading+0.2% full-scale)
High precision (optional, NIST traceable): ± (0.4% reading+0.2% full-scale)
Repeatability: 0.2% full scale
Standard controller response time constant: 5-10ms
No preheating time required
mwb3.PNG
working conditions
Compatible gases: 98 preset optional gases; Customize other mixed gases using COMPOSER gas editor
Working temperature: -10 ° C to+60 ° C
Maximum internal pressure (static): 45 psi (60 psi)
Maximum differential pressure (inlet to outlet): 15 psid
Pressure tolerance: 175 psi (190 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)

Packing List
MWB series portable low-pressure loss gas mass flowmeter (fully charged)
Micro USB charging cable and AC wall mounted adapter
NIST Traceable Calibration Certificate
Ericat Operating Manual

Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables
BB3 and BB9 multi-point junction boxes
Flow Vision software

Model variant
Standard configuration model, up to 160 psi (MB series)
High pressure application model, 160-320 psi (MBQ series)

Structural Options
Communication protocol (analog communication, RS-232, RS-485)
Display screen (monochrome or color)
Process connectors (NPT, SAE, AN, BSPP/G, welded compression or VCR/VCO joints)
Elastic materials (fluororubber, FFKM, EPDM, silicone resin)

Performance Options
Flow accumulator
High precision or custom calibration
WISHPER.PNG
MWB Erikat MWB series portable low-pressure loss gas mass flowmeter is suitable for non corrosive gases, commonly used models:
MWB-0.5SCCM-D
MWB-1SCCM-D
MWB-2SCCM-D
MWB-5SCCM-D
MWB-10SCCM-D
MWB-20SCCM-D
MWB-50SCCM-D
MWB-100SCCM-D
MWB-200SCCM-D
MWB-500SCCM-D
MWB-1SLPM-D
MWB-2SLPM-D
MWB-5SLPM-D
MWB-10SLPM-D
MWB-20SLPM-D
MWB-40SLPM-D
MWB-50SLPM-D
MWB-100SLPM-D
MWB-250SLPM-D
MWB-500SLPM-D
MWB-1000SLPM-D
Product application:
Calibration of air sampling tank
Gas mass flow meters can quickly calibrate multiple gases within a large range without the need for a computer. The traceability and high-precision options of NIST make portable mass flow meters a mobile calibration device. The MWB series portable low-pressure loss gas mass flowmeter can achieve non-invasive volumetric flow calibration.

mbq.PNG

MBQ series portable high-pressure gas mass flowmeter
Complete high-voltage application flow verification anytime, anywhere
This multi-functional MBQ series portable high-pressure gas mass flowmeter can shorten the time required for calibration or verification of operating flow under high pressure (160-320 psi) conditions, and can also provide real-time readings of multiple gases instantly, thereby reducing downtime and process interruption time.
Accurate. Flow calibration has NIST traceable accuracy and is suitable for various gases as low as 1/50th of full scale. It can also be performed using COMPOSER ™ Customize your own gas composition with the gas editor.
Efficient. As long as you open the MBQ series portable high-pressure gas mass flow meter, it can display real-time flow, pressure, and temperature readings in your selected process equipment.
Durable. The MBQ series portable high-pressure gas mass flowmeter is designed for easy portability and can resist the impact of falling.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
mq1.PNG

mq2.PNG
performance
Available range: maximum 0-5000 slpm; Minimum 0-10 sccm (see part number label for standard range)
Adjustable ratio: 50:1
Calibration accuracy (NIST traceable): ± 2% of full scale
Repeatability: 0.2% full scale
Standard controller response time constant: 5-10ms
No preheating time required
working conditions
mq3.PNG
Compatible gases: 98 (MBQ series) or 130 (MBQS series) preset optional gases; Customize other mixed gases using COMPOSER gas editor
Working temperature: -10 ° C to+60 ° C
Maximum internal pressure (static): 305 psi (320 psi)
Maximum differential pressure (inlet to outlet): 100 psid
Pressure tolerance: 400 psi (415 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)
Packing List

Alicat-new-logo-PCU_1200-768x985.jpg




MBQ series portable high-pressure gas mass flowmeter (fully charged)
Micro USB charging cable and AC wall mounted adapter
NIST Traceable Calibration Certificate
Ericat Operating Manual
Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables
BB3 and BB9 multi-point junction boxes
Flow Vision software

MBQ portable high-pressure gas mass flowmeter model:
MBQ-10SCCM-D
MBQ-20SCCM-D
MBQ-50SCCM-D
MBQ-100SCCM-D
MBQ-200SCCM-D
MBQ-500SCCM-D
MBQ-1SLPM-D
MBQ-2SLPM-D
MBQ-5SLPM-D
MBQ-10SLPM-D
MBQ-20SLPM-D
MBQ-50SLPM-D
MBQ-100SLPM-D
MBQ-250SLPM-D
MBQ-500SLPM-D
MBQ-1000SLPM-D
MBQ-2000SLPM-D
MBQ-3000SLPM-D
MBQ-5000SLPM-D
MBQS portable high-pressure corrosive gas mass flowmeter model:
MBQS-10SCCM-D
MBQS-20SCCM-D
MBQS-50SCCM-D
MBQS-100SCCM-D
MBQS-200SCCM-D
MBQS-500SCCM-D
MBQS-1SLPM-D
MBQS-2SLPM-D
MBQS-5SLPM-D
MBQS-10SLPM-D
MBQS-20SLPM-D
MBQS-50SLPM-D
MBQS-100SLPM-D
MBQS-250SLPM-D
MBQS-500SLPM-D
MBQS-1000SLPM-D
MBQS-2000SLPM-D
MBQS-3000SLPM-D
MBQS-5000SLPM-D


The M series gas mass flowmeter is suitable for many flow measurement application environments, with a variety of models that can measure flow rates up to 5000 slpm or as low as 0.0025 sccm.
If the pipeline pressure is high (145-305 PSI), please choose the MQ series high-pressure gas mass flowmeter.

The MW series low-pressure loss gas mass flowmeter is suitable for low-pressure loss application environments and can also shorten the aerodynamic response time under flow rate conditions of 50ccccm or lower.
Each series of mass flow meters mentioned above adopts a portable configuration powered by batteries: the MB series portable gas mass flow meters are suitable for typical application environments.
The MBQ series portable high-pressure gas mass flowmeter is suitable for high-pressure (145-305 PSI) pipelines.
The MWB series portable low-pressure loss gas mass flowmeter is suitable for low-pressure loss application environments.
Product application:
Filter performance test (M-series gas mass flowmeter)
Using a mass flow meter and pressure controller, determine the performance of the filter by comparing the flow rate and pressure loss curves.
Monitoring and Recording of Bioreactor Output (MW Series Gas Mass Flow Meter)
Quantify the mass flow rate of the bioreactor without inducing back pressure.
Quick leak test (M-series gas mass flowmeter)
In leak testing, the leakage rate is measured and the response time is only 5ms.
Internal flow calibration of gas chromatograph (MB series gas mass flowmeter)
Check the main and bypass flow rates to maintain optimal GC performance.
Calibration of Air Sampling Tank (MWB Series Gas Mass Flow Meter)
Low pressure loss can achieve non-invasive volumetric flow calibration.

Alicat-PCU-close-768x510.jpg

Alicat portable gas flow meters can quickly and easily complete system inspections, calibrations, and audits. All portable flow meters have laboratory level accuracy, can provide dynamic readings, and can be updated 1000 times per second.
0.6% reading accuracy in most flow meters
4 ms response time
No warm-up
Four process variables
Built in display
Industrial agreement
Pressure compensation
temperature compensation
Wide dynamic flow range
The AFS series portable gas flow calibrator is a mobile calibrator, characterized by the highest calibration accuracy, humidity compensation, and the ability to take average readings and record onboard data.
The FP-25 atmospheric sampling flow calibrator is an AFS that is not affected by weather and is specifically designed for calibrating outdoor atmospheric particulate matter (PM) samplers.
The MB series portable gas mass flowmeter is suitable for a variety of flow measurement applications and models, and can measure flow rates up to 5000 slpm or as low as 0.0025 sccm.
If the pipeline pressure is high (145-305 PSI), please choose the MBQ series portable high-pressure gas mass flowmeter.
The MWB series portable low-pressure loss gas mass flowmeter is suitable for low-pressure loss application environments and can also shorten the aerodynamic response time under flow conditions of 50ccccm or lower.
The PCU series portable gas flow calibrator is a portable mobile calibrator that combines three types of flow meters and has an extremely wide range of available ranges. When the range of a single flowmeter is insufficient to meet your calibration needs, please choose PCU series products.

LC-Batch-blue-P1010450_1200.jpg

A10.jpg
The Alicat liquid flow controller and flowmeter can accurately measure the flow rate of water or other liquids such as methanol, isopropanol, ethanol, ammonia, dimethyl ether, pentane, thiophene, standard iso octane or heptane, and stably control them. All liquid flow meters are equipped with drain screws for easy removal of the gas collection bag.

L1.PNG

The characteristics of LC series liquid flow controllers are as follows: using high-speed proportional control valves for control or distribution applications.

L-5SLM.PNG

For liquid flow measurement operations without control valves, please choose the L series liquid flowmeter to measure flow rate, pressure, and temperature in real-time.

LBS.PNG
The LB series portable liquid flow meter is equipped with a rechargeable battery for easy inspection of liquid flow outside the laboratory.

afs.PNG

AFS series portable gas flow calibrator, portable ready to use gas flow calibrator
If your calibration process requires extremely high accuracy, you can choose the AFS series portable gas flow calibrator in portable gas flow meters. It is Erikat's most advanced calibration instrument, ensuring optimal performance in constantly changing temperatures, and equipped with a relative humidity sensor that can maintain its accuracy at 100% RH (non condensing) at all times. It is precisely because of these advanced features that it is possible to maintain a reading accuracy of 1% without utilizing other full-scale components.
FP-25-kit-P1040704.jpg
Accurate. Flow calibration has a NIST traceable 0.75% reading accuracy, suitable for various gases, and can also be performed using COMPOSER ™ Customize your own gas composition with the gas editor. Low pressure loss minimizes the impact of volume flow calibration on the system.
Easy and fast operation. Average measurement values and onboard data recording facilitate the collection of multivariate flow data (volume flow and standardized flow, atmospheric pressure and pipeline pressure, pipeline temperature, etc.).
Durable. The AFS series portable gas flow calibrator is designed for easy portability and can withstand the effects of falling. The process connectors have SAE threads and excellent leak proof performance.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
fp1.PNG
performance
Available range: maximum 0-50 slpm; Minimum 0-5 sccm (for all ranges, please refer to the part number label)
Adjustable ratio: 200:1 (flowing air); 20: 1 (Other flowing gases or mixed gases)
Flow accuracy (NIST traceable):+/-0.75% reading
Standard controller response time constant: 5-10ms
No preheating time required
working conditions
fp2.PNG
Compatible gases: 98 preset optional gases; Customize other mixed gases using COMPOSER gas editor
Working temperature: -10 ° C to+60 ° C
Maximum internal pressure (static): 45 psi (160 psi)
Maximum differential pressure (inlet to outlet): 15 psid
Pressure tolerance: 175 psi (190 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)
Packing List
Alicat-new-logo-PCU.jpg
AFS series portable gas flow calibrator
Micro USB to USB charging cable and communication cable
Wall mounted USB adapter for charging
NIST Traceable Calibration Certificate

FP-25-kit.jpg
Ericat Operating Manual
Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables
Alicat-FP-25BT-on-BAM-1020_lb.jpg
Calibration of Mass Flow Controller in Dynamic Gas Dilution Calibration Instrument
Performing a 20 point mass flow controller flow calibration only takes a few minutes, not hours. You don't need to waste time waiting for the positive displacement volumetric measuring instrument to complete a small flow measurement. The AFS series portable gas flow calibrator saves you hours of calibration time and can instantly provide the minimum flow reading. It can display both actual volumetric flow rate and standardized mass flow rate, making it convenient to obtain the information you need.

alicat气象.png
Setting of flow controller for air sampling tank
Use AFS series portable gas flow calibrator low pressure loss product to set up a volume flow controller for VOC air sampling tank. Due to its ability to provide real-time readings of small flow rates, this product can easily ensure obtaining the flow rate of the set sample in the sampling tank. The AFS series portable gas flow calibrator has a wide 200:1 adjustable ratio when used for air, with great flexibility to adapt to various sizes of sampling tanks and sampling periods.
Calibration of gas analyzers, pumps, and atmospheric sampling instruments for industrial hygiene applications
Quickly verify the sample flow rates of various gas analyzers, pumps, and atmospheric sampling instruments used in industrial hygiene applications. It can complete flow calibration within seconds and provide real-time volumetric flow and standardized flow readings. The average value function of the AFS series portable gas flow calibrator can record 1000 readings per second for oscillating pumps, thereby obtaining stable flow data. The ultra-low pressure loss and push-pull function make the AFS series portable gas flow calibrator suitable for calibrating all models of atmospheric sampling instruments and analyzers.
FP-25-flow-audit-inset.jpg
FP-25 Atmospheric Sampling Flow Calibration Instrument
Accurate air flow calibration can be completed under any weather conditions
In portable gas flow meters, only one instrument can calibrate flow rate, pressure, and temperature with laboratory level accuracy without any malfunctions. Erikat's FP-25 and FP-25T (with Bluetooth) atmospheric sampling flow calibrators can calibrate every small capacity particulate matter atmospheric sampler on your desk. Accuracy and durability under various weather conditions ensure continuous display of readings, unaffected by wind, temperature, or humidity.

Accurate reading. No matter what climate conditions you are in, you don't have to doubt the results of flow measurement! The FP-25 atmospheric sampling flow calibrator has a sensitive external temperature probe and humidity sensor that can monitor flow, pressure, and temperature in real time while also monitoring weather conditions at any time. It outputs a stable average value at a rate of 5000 measurements every 5 seconds.
Easy and fast operation. Equipped with Bluetooth connection (FP-25BT only), reducing the need to run up and down to record data. The industry's unique straight through PM10/PM2.5 inlet connector can be quickly connected to any small capacity air sampler, or connected to the air sampler through the accompanying surface sealed hook connector. Fast temperature balancing allows you to immediately start flow calibration.
Durable structure. Whether it falls from the roof or starts raining after inspection, it does not affect the continuation of flow calibration. This calibrator has a compact structure and can be carried around in your jacket pocket. Its all aluminum material makes it more durable and can work in any harsh weather environment, and it also enjoys a unique lifetime warranty service in the industry!
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
Alicat-FP-25-DM-on-Partisol-2000-sm.jpg
performance

Flow range: 0.125-25.000 lpm/slpm
Flow calibration accuracy (NIST traceable):+/-1% reading
Atmospheric pressure calibration accuracy (NIST traceable):+/-1 mmHg
Temperature calibration accuracy (NIST traceable):+/-0.2 º C
Pressure loss: 0.10 psi under 16.7 lpm conditions; 0.16 psi under 25.0 lpm conditions
Standard flow reading response time constant: 5ms (may take up to 10ms under extremely low flow conditions)
Standard temperature and humidity balance time: within 5 minutes
working conditions
Alicat-FP-25-SM-on-Partisol-2000-smcr.jpg
Compatible gas: Air only
Working temperature: -30 ° C to+60 ° C
Atmospheric pressure: 475-825 mmHg
Maximum internal pressure (static): 45 psi (60 psi)
Maximum differential pressure (inlet to outlet): 15 psid
Pressure tolerance: 175 psi (190 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)
Packing List

FP-25 Atmospheric Sampling Flow Calibration Instrument
External temperature probe (wire length 6 feet, M8 interface)
Bluetooth antenna
Micro USB to USB connection cable for charging and communication
Wall mounted USB adapter for charging
1/4 '' NPT surface sealing hook adapter (1/4 '' hook)
1/4 '' NPT surface sealing joint (directly connected to the lower tube of 1-1/4 '' OD atmospheric sampler)
NIST Traceable Calibration Certificate
Operation Manual
Adjustable hard portable case
Alicat FP-25 flow calibrator kit contents
[Erikat FP-25 Flow Calibration Kit Contents]
Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables

Vacuum-Coating-Pressure-Photo360ed_12001.jpg
FP-25 (FP-25 kit with accessories and hard case) FP25
FP-25BT (FP-25 kit with Bluetooth antenna) FP25BT
Attachment model:
FP-PROBE (replacement external temperature probe)
FP-DMA1 (replacement Direct Mode inlet adapter with face seal)
FP-DMA2 (replacement Direct Mode outlet adapter with face seal)
FP-BARB (replacement barb adapter with face seal)
FP-TUBE (replacement tubing for barb connections)
FP-BTA (replacement Bluetooth antenna, compatible with FP-25BT only)
PVPS5USBU (replacement micro-USB cable and wall adapter)
SCASE (replacement hard case with custom foam inserts for FP-25 and FP-25BT)
pcu3.jpg
PCU series portable gas flow calibrator
Portable flow calibrator with extremely wide dynamic range span
When a single flow meter cannot meet all your calibration needs, consider using the PCU series portable gas flow calibrator in portable gas flow meters. Ericat's PCU series portable gas flow calibrator is a secondary calibration instrument that integrates three high-precision flow meters and accumulators with different ranges (up to 1500 slpm) into a durable industrial box for easy portability. The PCU series portable gas flow calibrator can be powered by two 9-volt batteries or an accompanying AC cable, and is also equipped with an Ericat Flow Vision SC ™ Software.
pcu2.jpg
multi-functional Equipped with simple push connection connectors or optional pressure connectors, with a comprehensive adjustable range of up to 1000000:1 (e.g. 1 sccm – 1000 slpm), it can quickly calibrate multiple instruments.
Accurate. Real time measurement and completion of flow accumulation, with NIST traceable accuracy (0.4% reading+0.2% full scale), suitable for various gases as low as 1/200th of full scale, and can also use COMPOSER ™ Customize your own gas composition with the gas editor.
Durable. The PCU series portable gas flow calibrator integrates the flow meter into a durable hard box and can resist the impact of falling.
The PCU series portable gas flow calibrator also includes our Whisper series low pressure loss configuration models (i.e. PCUW series) and 316L configuration models (i.e. PCUS series) that can be used for corrosive gases.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
pc1.PNG

pc2.PNG
performance
Available range:
Choose any three flow meters with a range not exceeding 1500 slpm (PCU and PCUS) or 250 slpm (PCUW)
pcu4.jpg
All flow meters are equipped with flow accumulators
Adjustable ratio: up to 1000000:1 (comprehensive adjustable ratio of 3 instruments)
High calibration accuracy (NIST traceable) (PCU standard accuracy): ± 0.4% reading+0.2% full-scale
Repeatability: 0.2% full scale
Standard controller response time constant: 5-10ms
No preheating time required
working conditions
pc3.PNG
Compatible gases: 98 (PCU and PCUW series) or 130 (PCUS series) preset optional gases; Customize other mixed gases using COMPOSER gas editor
Working temperature: -10 ° C to+60 ° C
Maximum internal pressure (static): 145 psi/160 psi (PCU and PCUS series) or 45 psi/60 psi (PCUW series)
Maximum differential pressure (inlet to outlet): 75 psid (PCU and PCUS series) or 15 psid (PCUW series)
Pressure tolerance: 175 psi (190 psi)
STP/NTP: User selectable (default is 25 ° C&1 atm STP/0 ° C&1 atm NTP)
Packing List
pcu1.jpg
PCU series portable gas flow calibrator (with up to three high-precision mass flow meters installed internally)
Push connection joints installed below each flowmeter display screen
USB A-B cable (for connecting to a computer)

pcu5.jpg
Double ended 9-pin D-sub analog interface serial cable (used to connect with multi-point junction box)
Universal power supply
Flow Vision SC software
NIST traceable calibration certificates for each flowmeter
Ericat Operating Manual
Accessories (to be ordered separately)
PCU-calibration.jpg
power supply
Communication cables and conversion cables
pcu6.jpg
Calibration of multi flow meters
The PCU series portable gas flow calibrator combines three free range battery powered flow meters in one case, each with an accumulator and high-precision calibration to NIST traceable primary flow standards. Due to the three overlapping measurement ranges, the PCU series portable gas flow calibrator can reduce the total range to 1 million to 1, making it an extremely versatile instrument.
PCU-0.5SCCM-10SCCM-1SLPM
PCU-10SCCM-500SCCM-20SLPM
PCU-100SCCM-2SLPM-20SLPM
PCU-100SCCM-10SLPM-100SLPM
PCU-100SCCM-50SLPM-500SLPM
PCU-10SLPM-50SLPM-1500SLPM
PCUS-0.5SCCM-10SCCM-1SLPM
PCUS-10SCCM-500SCCM-20SLPM
PCUS-100SCCM-2SLPM-20SLPM
PCUS-100SCCM-10SLPM-100SLPM
PCUS-100SCCM-50SLPM-500SLPM
PCUS-10SLPM-50SLPM-1500SLPM
PCUW-0.5SCCM-10SCCM-1SLPM
PCUW-10SCCM-500SCCM-20SLPM
PCUW-100SCCM-2SLPM-20SLPM
PCUW-100SCCM-10SLPM-100SLPM
PCUW-100SCCM-50SLPM-250SLPM
PCUW-10SLPM-50SLPM-250SLPM
L.PNG
L series liquid flowmeter
Real time measurement of multiple liquid flow rates
In liquid flow controllers and flow meters, the L series liquid flow meter can simultaneously measure flow rate, pipeline pressure, and pipeline temperature in real-time, and can optionally be equipped with an accumulator to track the accumulated flow rate over time.
L1.PNG
Accurate. Water flow measurement has NIST traceable accuracy and is suitable for water as low as 1/50th of full scale. Other calibratable liquids include methanol, isopropanol, ethanol, ammonia, dimethyl ether, pentane, thiophene, standard iso octane, and heptane.
Easy to use. Once you turn on the flow meter, it will display real-time flow, pressure, and temperature readings from the selected process equipment.
connect. The default communication methods for the L series liquid flowmeter are digital and analog; When ordering, Ethernet/IP, EtherCAT, DeviceNet, Profibus, or Modbus (RTU and TCP/IP) communication can be selected for easy integration with your digital industrial or laboratory network.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
L2.PNG
performance

Available range: maximum 0-10 lpm; Minimum 0-0.5 ccm (for the standard range, please refer to the part number)
Adjustable ratio: 50:1
Calibration accuracy (NIST traceable): ± 2% of full scale
Repeatability: 2% full scale
Standard controller response time constant: 20ms
No preheating time required
working conditions
L3.PNG
Default calibration liquid: water
Other calibration liquids (must be specified at the time of ordering): methanol, isopropanol, ethanol, ammonia, dimethyl ether, isopentane, thiophene, standard iso octane, heptane
Working temperature: -10 ° C (unfrozen) to+60 ° C
Maximum internal pressure (static): 100 psi (115 psi)
Pressure tolerance: 200 psi (215 psi)
Packing List
L series liquid flowmeter (power supply needs to be ordered separately)
NIST Traceable Calibration Certificate
Ericat Operating Manual
Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables
BB3 and BB9 multi-point junction boxes
Flow Vision software
L4.PNG
Liquid flow characteristic test
The L series liquid flowmeter can be used to determine the characteristics of pump water flow rate or the characteristics of medical catheter saline flow rate. The optional flow accumulator can easily quantify the total amount of liquid that has flowed through during the testing process.
L-0.5CCM-D
L-1CCM-D
L-2CCM-D
L-5CCM-D
L-10CCM-D
L-20CCM-D
L-50CCM-D
L-100CCM-D
L-200CCM-D
L-500CCM-D
L-1LPM-D
L-2LPM-D
L-5LPM-D
L-10LPM-D
Filter-Characterization-Photo360ed_1200.jpg
LS-0.5CCM-D
LS-1CCM-D
LS-2CCM-D
LS-5CCM-D
LS-10CCM-D
LS-20CCM-D
LS-50CCM-D
LS-100CCM-D
LS-200CCM-D
LS-500CCM-D
LS-1LPM-D
LS-2LPM-D
LS-5LPM-D
LS-10LPM-D
LB.PNG
LB series portable liquid flowmeter
Implement multi-dimensional liquid flow measurement at any time
In liquid flow controllers and flow meters, the LB series portable liquid flow meters can shorten downtime and process interruption time, simplify calibration and verification processes. This product can display instantaneous real-time flow, pipeline pressure, and pipeline temperature readings, allowing you to quickly stop and start. At the same time, this product can be equipped with an accumulator to track the accumulated traffic that changes over time.
Accurate. The water flow calibration has NIST traceable accuracy and is suitable for water as low as 1/50th of full scale. Other calibratable liquids include methanol, isopropanol, ethanol, ammonia, dimethyl ether, pentane, thiophene, standard iso octane, and heptane.
Easy to use. Once you turn on the flow meter, it will display real-time flow, pressure, and temperature readings from the selected process equipment.
connect. The LB series portable liquid flowmeter is designed for easy portability and can withstand the impact of falling.
Alicat provides advanced solutions for mass flow meters, mass flow controllers, pressure controllers, and pressure sensors.
L1.PNG

L2.PNG
performance
Available range: maximum 0-10 lpm; Minimum 0-0.5 ccm (for the standard range, please refer to the part number)
Adjustable ratio: 50:1
Calibration accuracy (NIST traceable): ± 2% of full scale
Repeatability: 2% full scale
Standard controller response time constant: 20ms
No preheating time required
working conditions

Default calibration liquid: water
Other calibration liquids (must be specified at the time of ordering): methanol, isopropanol, ethanol, ammonia, dimethyl ether, isopentane, thiophene, standard iso octane, heptane
Working temperature: -10 ° C (unfrozen) to+60 ° C
Maximum internal pressure (static): 100 psi (115 psi)
Pressure tolerance: 200 psi (215 psi)
Packing List
L3.PNG
LB series portable liquid flowmeter (fully charged)
Micro USB charging cable and AC wall mounted adapter
NIST Traceable Calibration Certificate
Ericat Operating Manual
Accessories (to be ordered separately)
Process port connectors and filters
power supply
Communication cables and conversion cables
BB3 and BB9 multi-point junction boxes
Flow Vision software
L4.PNG
Cooling system leakage inspection
When conducting leak tests on cooling systems anywhere in the factory, the LB series portable liquid flow meter can quickly quantify the water flow rate and display multiple readings such as pipeline flow rate, pressure, and temperature without the need for a computer connection.
LB-0.5CCM-D
LB-1CCM-D
LB-2CCM-D
LB-5CCM-D
LB-10CCM-D
LB-20CCM-D
LB-50CCM-D
LB-100CCM-D
LB-200CCM-D
LB-500CCM-D
LB-1LPM-D
LB-2LPM-D
LB-5LPM-D
LB-10LPM-D
IMG_0123.jpg
LBS-0.5CCM-D
LBS-1CCM-D
LBS-2CCM-D
LBS-5CCM-D
LBS-10CCM-D
LBS-20CCM-D
LBS-50CCM-D
LBS-100CCM-D
LBS-200CCM-D
LBS-500CCM-D
LBS-1LPM-D
LBS-2LPM-D
LBS-5LPM-D
LBS-10LPM-D

For more information on ALICAT flow meters, ALICAT flow controllers, ALICAT pressure controllers, models, prices, and technical issues, please call us for consultation//