detailed description:
The TIGER SELECT benzene vapor detector can detect benzene and all aromatic volatile organic compounds with one instrument by switching between two detection modes. Tiger Select has two detection modes for benzene and aromatic compounds (TACs) to provide you with accurate and reliable detection data
Advantages:
*Real time display of test results - no need to wait for long readings
*Detecting benzene through the pre installed Draeger filter tube
*It can also be detected in a space containing only benzene without the need for a special filter tube
*Can achieve ppb level detection
*Rapid detection of aromatic compounds (TACs)
*Confirmed the superior performance of PID
National standard for indoor air quality in China: 1-hour average is 0.11mg/m3
Occupational health standard: TWA 6mg/m3 STEL 10mg/m3
American ACGIH 10ppm, 32mg/m3 TWA: OSHA 1ppm 3.2mg/m3
Features:
*Very easy to operate and intuitive software
*Large and clear display screen and buttons
*Even with thick gloves, the operation remains flexible
*The instrument is lightweight and can be operated with one hand
*Battery life up to 30 hours
*Background lighting fixtures have photosensitive function
Technical specifications:
Minimum resolution: 10ppb or 0.033mg/m3 (benzene)
Maximum range: 40 ppm or 130mg/m3 (benzene measurement mode)
At least 4000 ppm (aromatic compound detection mode)
Accuracy: ± 10% reading or ± 1 value (benzene)
Linear: ± 5% to 40 ppm (benzene)
Response time: 120 seconds. Real time display of benzene status.
Intrinsic safety certification: II 2G Ex ia IIC T4 (-15 ° C ≤ Ta ≤+60 ° C)
ITS09 ATEX 26890X
IECEx ITS 10.0036X
Certification applications in the United States and Canada
Battery usage time: Lithium battery: up to 30 hours, charging time 6.5 hours, alkaline battery: 3 × AA, typical 12 hours
PID lamp: Krypton PID lamp equipped with energy conversion module
Data storage:>120000 data storage with date and time
Communication: USB 1.1
Calibration: 2-point or 3-point calibration (via calibration tool kit)
Alarm: LED flashing light and 95dBA 300mm (12 ") speaker
Optional vibration alarm: pre-set TWA and STEL
Flow rate: 220ml/min (150 cc/min with low flow alarm)
Temperature: Operating temperature: -20~60 ℃, -4~140 ℉ (non intrinsic safety)
Humidity: 0~99% RH (non condensing)
Protection level: IP 65 waterproof design
CE1180:EMC tested TO EN61326-1:2006,EN50270:2006 G CFR 47:2008 Class A
Weight and volume: The instrument includes probes but not hoses, with a width of 456 x height of 89 x depth of 61mm (18.3 x 3.5 x 2.4 ")
Revolutionary portable detector Tiger
Select has two detection modes. One is the detection mode for aromatic compounds (TACs); Another method is to measure benzene through a pre filter tube.
The detection system adopts a high output ION, which can immediately read the data of aromatic compounds (TACs) when turned on. In addition, a pre filter tube can be installed for benzene detection. The instrument can display the 15 minute STEL and 8-hour TWA values of TACs.
During the measurement period, Tiger Select can continuously display real-time data. The displayed concentration of benzene can reach 10 ppb, allowing you to obtain accurate and reliable data.
In addition, the unique mini PID VOC sensor combines anti fouling technology and grid electrode technology, which can be applied in difficult working environments.
Tiger Select can also use the standard Tiger mode, without the need to insert a pre filter benzene tube, to detect VOCs, including concentrations as low as 1 ppb.
Application:
*Occupational health and safety monitoring
*IAQ Indoor Air Quality Monitoring
*TAC testing of unloading docks and barge operations
*Access to confined spaces in refineries and factories
*Hazardous substance reactions
*Toxic gas leakage reaction