ESO2TheNOXTheO2Smoke and dust, temperature, pressure, flow rate, humidity
ESmoke sampling method: extraction condensation method
ESO2TheNOXMonitoring method: UV spectroscopy
EO2Monitoring method: electrochemical method
ESmoke and dust measurement method: laser backscatter method
ETemperature measurement method: temperature sensor
EPressure measurement method: pressure sensor
EFlow velocity measurement method: differential pressure method (pitot tube)
EHumidity: Resistance capacitance method
ESampling probe adoptsSUS316L 不锈钢
EThe temperature pressure flow integrated monitoring instrument adoptsSUS316L stainless steel, with anti-corrosion treatment for the pitot tube
EThe heat tracing pipeline adoptsPTFE material, high corrosion resistance
EThe pre-processing system interface adoptsPTFE material, high corrosion resistance
EThe condenser condenser tube is made of tempered glass material with high corrosion resistance
|
qi body filth dye thing divide analyze ceremony |
Measurement components |
SO2 |
NOX |
O2 |
||
Measuring principle |
UV或NDIR |
UV或NDIR |
electrochemistry |
|||
range |
0-50ppm -150ppm optional |
0-50ppm -150ppm optional |
0-5%/0-25% |
|||
CO、CO2TheNH3、HCL, HF, etc. are optional | ||||||
zero drift |
≤2% |
|||||
Span Drift |
≤2% |
|||||
response time |
≤ 7 seconds |
|||||
display |
With backlightLCD |
|||||
Sample gas flow rate |
0.2±1.5L/min |
|||||
Sampling probe |
Electric heat tracing with temperature alarm; Equipped with blowing and calibration functions; Probe length1500, other options available; Flange DN65, PN6.0 |
|||||
Sampling tube |
Electric heat tracing,PTFE, two pieces with a diameter of 8/6 |
|||||
calibration |
Automatic or manual options available |
|||||
standard |
Zero point gas |
N2 |
||||
gas |
span gas |
Standard gas corresponding to the tested component |
||||
|
particulate matter |
Measuring principle |
extractive |
||||
Measure optical path length |
Scattering method |
|||||
measurement range |
0-15-200mg/m³ 可选 |
|||||
|
Smoke parameters |
temperature |
0-300 ℃ optional |
||||
pressure |
-2.5-+2.5kPa |
|||||
flow velocity |
0-40m/s optional |
|||||
humidity |
0-40Vol% |
|||||
|
Data acquisition and processing system |
Industrial PC |
Intel Core processor, 500GB hard drive, 2G memory, 24x optical drive, 4U19 "chassis, 17" LCD, Windows 7 Professional operating system |
||||
system software |
CEMS-CEMS-8000LSystem monitoring software |
|||||
output signal |
standard configurationGPRS communication module, analog signal, switch signal RS485、 Ethernet |
|||||
cabinet |
size |
700mm * 700mm * 2000mm (depth * width * height) |
||||
structure |
Front single door with tempered glass window, interior19 inch manual bracket |
|||||
color |
RAL7047 milky white |
|||||