E-mail
312534289@qq.com 467090947@qq.com
-
Phone
18761882890/13814089468
-
Address
15-20 Xingda Road, Nanjing Yangtze River Industrial Development Zone
Nanjing Zhuoma Electromechanical Co., Ltd
312534289@qq.com 467090947@qq.com
18761882890/13814089468
15-20 Xingda Road, Nanjing Yangtze River Industrial Development Zone
>COD CR online automatic monitoring instrument
Chemical Oxygen Demand (COD) is a chemical method used to measure the amount of reducible substances that need to be oxidized in a water sample. Under certain conditions, the amount of oxidant consumed to oxidize reducing substances in 1 liter of water sample is used as an indicator to convert it into milligrams of oxygen required per liter of water sample after complete oxidation, expressed in mg/L. It reflects the degree of pollution caused by reducing substances in water. This indicator is also one of the comprehensive indicators of the relative content of organic matter.
|
Ø Performance characteristics ·The digestion colorimetric process of the instrument is completed in one, with a simple and reliable structure, reducing the possibility of errors. ·Adopting imported modified polytetrafluoroethylene transparent hose with a diameter greater than 1.5mm, reducing the probability of particle blockage in water samples. ·It can automatically clean the sampling pipeline to prevent the formation of algae or biofilm. ·After abnormal reset and power failure, the instrument will automatically discharge residual reactants and restore working status. ·Low failure rate, minimal maintenance, and low reagent consumption. ·The intelligent fault self diagnosis function, alarm prompt, instrument management and maintenance are very convenient. ·Adopting multi-channel valves, it has strong anti-corrosion performance, long service life, and is safe and reliable.
Ø Application Fields Suitable for wastewater with chemical oxygen demand ranging from 10 to 2000 mg/L and chloride concentration below 2.5 g/L Cl ¯, according to user requirements, it can be applied to wastewater with chloride concentration below 20 g/L Cl ¯.
Online monitoring of industrial pollution source wastewater Online monitoring of industrial process water usage Online monitoring of water quality at the inlet and outlet of municipal sewage treatment plants |
|
Ø Technical parameters
|
Model number |
DH310C1 |
|
Method basis |
National standard GB11914-89 "Water Quality - Determination of Chemical Oxygen Demand - ********* Salt Method" |
|
measurement range |
10~2000mg/L COD |
|
Accuracy |
Indication error ≤± 10% |
|
repeatability error |
≤±10% |
|
measurement period |
The small measurement cycle is 40 minutes, and according to the actual water sample, the digestion time can be arbitrarily modified within 5-20 minutes. |
|
sampling period |
Time interval (adjustable from 20 to 9999min) and hourly measurement mode |
|
Correction |
The instrument can perform sensitivity and zero calibration at regular intervals |
|
calibration cycle |
Adjustable at any interval and time from 1 to 99 days |
|
maintenance cycle |
Usually once a month, about 30 minutes each time |
|
analog output |
2-channel 4-20mA |
|
signal interface |
RS232 or RS485 |
|
Switching quantity |
6 sets of relay control, capacity 220VAC/2A |
|
Comparison of actual water samples |
Error ≤± 10% |
|
MTBF |
≥ 720h/time |
|
Environmental Requirements |
Suggested temperature+5-28 ℃; Humidity ≤ 90% (non condensing) |
|
Size |
Height 1500 x Width 550 x Depth 450 (mm) |
|
Power supply |
AC220±10%V,50±10%Hz,5A |
|
Other |
Abnormal alarms and power outages will not result in data loss; Touch screen display and command input; After abnormal reset and power failure, the instrument will automatically discharge residual reactants from the device and restore its working state |

Workstation installation (recommended) plan diagram
an>