CZ round cable with reinforced core cableProduct Description:
This product is suitable for household appliances, power tools, and various mobile electrical equipment with AC rated voltage of 450/750V and below.
1、 Production Execution Standard: JB8735.2-1998
2、 Usage characteristics
1. Rated voltage 300/500V (YZ type), 450/750V (YC type);
2. The long-term allowable working temperature of the wire core should not exceed 65 ℃;
3. The "W" type cable has weather resistance and certain oil resistance, making it suitable for use outdoors or in contact with oil stains;
4. Z-type cables have flame retardant properties.
3、 Model, name, and main purpose are listed in Table 1
Table 1
| model | name | main purpose |
| YQ,YQW | Lightweight rubber sheathed flexible cable | Used for lightweight mobile electrical equipment and tools |
| YZ,YZW | Medium sized rubber flexible cable | Used for various mobile electrical devices and tools |
| YC,YCW | Heavy duty rubber sheathed flexible cable | Used for various mobile electrical devices, capable of withstanding large mechanical external forces |
The specification range is shown in Table 2
Table 2
| model | Rated voltage (V) | core count | Nominal cross-section (mm2) |
| YQ,YQW | 300/300 | 2,3 | 0.3~0.5 |
| YZ,YZW | 300/500 | 2,3,4,5 | 0.75~6 |
| YC,YCW | 450/750 | 1 2 3,4 5 | 1.5~240 1.5~95 1.5~150 1.5~25 |
CZ round cable with reinforced core cableThe specifications, dimensions, and technical parameters are shown in Tables 3-5
Table 3 YQ, YQW type 300/300V
| Nominal cross-section (mm2) | conductor structure | Conductor resistance at 20 ℃ ≤(Ω/km) | Cable outer diameter reference (mm) | |
| Root/single wire diameter mm | 2-core | 3-core | ||
| 0.3 | 16/0.15 | 69.2 | 6.6 | 7.0 |
| 0.5 | 28/0.15 | 39.0 | 7.2 | 7.6 |
Table 4 YZ, YZW type 300/500V
| Nominal cross-section (mm2) | conductor structure | Conductor resistance at 20 ℃ ≤(Ω/km) | Cable outer diameter reference (mm) | ||||
| Root/single wire diameter mm | 2-core | 3-core | 4-core | 5-core | 3+1 core | ||
| 0.75 | 24/0.20 | 26.0 | 8.2 | 8.8 | 9.6 | 11.0 | — |
| 1.0 | 32/0.20 | 19.5 | 8.8 | 9.2 | 10.0 | 11.5 | — |
| 1.5 | 30/0.25 | 13.3 | 10.5 | 11.0 | 12.5 | 13.5 | 12.0 |
| 2.5 | 49/0.25 | 7.98 | 12.5 | 13.0 | 14.0 | 15.5 | 14.0 |
| 4 | 56/0.30 | 4.95 | 14.0 | 14.5 | 16.5 | 18.0 | 16.0 |
| 6 | 84/0.30 | 3.30 | 17.0 | 18.0 | 20.0 | 22.5 | 19.5 |
Table 5 YZ, YZW type 300/500V
| Nominal cross-section (mm2) | conductor structure | Conductor resistance at 20 ℃ ≤(Ω/km) | Cable outer diameter reference (mm) | |||||
| Root/single wire diameter mm | 1 core | 2-core | 3-core | 4-core | 5-core | 3+1 core | ||
| 1.5 | 30/0.25 | 13.3 | 7.2 | 11.5 | 12.5 | 15.5 | 15.0 | — |
| 2.5 | 49/0.25 | 7.98 | 8.0 | 13.5 | 14.5 | 16.5 | 17.0 | 15.5 |
| 4 | 56/0.30 | 4.95 | 9.0 | 15.0 | 16.0 | 18.0 | 19.5 | 17.5 |
| 6 | 84/0.30 | 3.30 | 11.0 | 18.5 | 20.0 | 22.0 | 24.5 | 21.0 |
| 10 | 84/0.40 | 1.91 | 13.0 | 24.0 | 25.5 | 28.0 | 31.0 | 26.5 |
| 16 | 126/0.40 | 1.21 | 14.5 | 27.5 | 29.5 | 32.0 | 35.5 | 30.5 |
| 25 | 196/0.40 | 0.780 | 16.5 | 31.5 | 34.0 | 37.5 | 41.5 | 35.5 |
| 35 | 276/0.40 | 0.554 | 18.5 | 35.5 | 38.0 | 42.0 | — | 38.5 |
| 50 | 396/0.40 | 0.386 | 21.0 | 41.0 | 43.5 | 48.5 | — | 46.0 |
| 70 | 360/0.50 | 0.272 | 24.0 | 46.0 | 49.5 | 55.0 | — | 51.0 |
| 95 | 475/0.50 | 0.206 | 26.0 | 50.5 | 54.0 | 60.5 | — | 55.0 |
| 120 | 608/0.25 | 0.161 | 28.5 | — | 59.0 | 65.5 | — | 59.0 |
| 150 | 756/0.50 | 0.129 | 32.0 | — | 66.5 | 74.0 | — | 66.0 |
| 185 | 925/0.50 | 0.106 | 34.5 | — | — | — | — | — |
| 240 | 1221/0.50 | 0.0801 | 38.0 | — | — | — | — | — |
Delivery requirements
1. Forming a circle of 100M, the disk should be greater than 100M;
2. The length of short cables shall not be less than 10M, and the delivery quantity of short cables shall not exceed 10% of the total delivery length, and each package shall not exceed five sections;
3. According to the agreement between both parties, any length of cable is allowed for delivery, with a length error of ± 0.5%;
4. Users have flame retardant requirements for the product, and a supplementary agreement needs to be included in the contract.