Background Introduction to the Use of Cash Document Disinfection Cabinet: Due to circulation issues, cash often has a lot of bacteria on it. Now, as various enterprises and institutions resume work, the problem of cash document disinfection is urgent. The current disinfection method is to use75%Medical grade alcohol. Wear gloves. Spray alcohol with a small spray bottle and let it dry before washing hands to ensure hygiene. The method is cumbersome and the spraying leaves dead corners. Our company is now launching a cash document disinfection cabinet, which is a device used for sterilizing and disinfecting cash documents. It adopts ozone disinfection method, which can quickly kill Escherichia coli, Staphylococcus aureus, hepatitis bacteria, mold and various pests contaminated on paper products. Users can choose different control times for sterilization and disinfection according to the degree of contamination of the items. This product has the characteristics of sterilization, high disinfection efficiency, *, no pollution, long service life, etc., and is suitable for sterilization and disinfection of cash, documents, files and other items that cannot be sterilized at high temperatures.
model |
Use power supply V/HZ |
content volume (L) |
Ozone concentration (ppm) |
Product outer dimensions (mm) L×W×H |
Product internal dimensions (mm) L×W×H |
JCF-SG-100 |
220/50 |
100 |
200-500 |
450×300×800 |
400×300×650 |
JCF-SG-200 |
220/50 |
200 |
200-500 |
650×500×1200 |
500×470×880 |
JCF-SG-300 |
220/50 |
300 |
200-500 |
750×550×1350 |
600×500×1000 |
JCF-SG -400 |
220/50 |
400 |
200-500 |
850×550×1500 |
700×500×1150 |
JCF-SG -500 |
220/50 |
500 |
200-500 |
950×550×1600 |
800×500×1250 |
JCF-SG -600 |
220/50 |
600 |
200-500 |
1050×650×1700 |
800×600×1250 |
JCF-SG -1000 |
220/50 |
1000 |
200-500 |
1360×650×1800 |
1200×600×1450 |
JCF-SG-2000 |
220/50 |
2000 |
200-500 |
1560×800×2300 |
1400×750×1900 |
1Preparation for Inspection:
Place the disinfected items by category upside down or diagonally on the shelves of the corresponding disinfection room. Pay attention to leaving a certain gap between each other to avoid affecting the disinfection effect. Close the cabinet door.
2Operation:
2.1Close the cabinet door, turn on the power, and disinfect. During the disinfection process, the cabinet door cannot be opened.
2.2Press the disinfection button, the disinfection indicator light will turn on, indicating that the cabinet is ready to start disinfection.
2.3Turn on the timer, the ozone working indicator light will turn on, indicating the start of ozone cleaning work. After the cycle is completed, the ozone indicator light will turn off, and the ozone sterilization work will be completed.
2.4Disinfection completed, cut off the power, wait20Open the cabinet door in minutes, take out the disinfectant items, and the disinfection work is completed.
3Maintenance and upkeep
3.1When the disinfection cabinet is not in use, open the cabinet door to dry and then close it to keep the inside dry. Even if not used, it is necessary to heat it every few days to remove moisture and prevent poor contact of internal electrical components due to moisture.
3.2Do not use the disinfection cabinet as a storage cabinet to store items, as it may cause the disinfection cabinet to become damp.
3.3Regularly clean the inside and surface of the disinfection cabinet to keep it clean and hygienic. When cleaning, only use a soft cloth dipped in neutral detergent or water to wipe, and then wipe dry.
3.4The disinfection cabinet should be placed in a ventilated and dry place.
3.5Before cleaning the disinfection cabinet, the power plug should be unplugged, and the surface of the cabinet should be wiped with a clean cloth dipped in warm water or neutral cleaning agent. Do not use highly corrosive chemical liquids to wipe, so as not to corrode the cabinet. It is strictly prohibited to splash a large amount of water on the washing and disinfection cabinets to avoid electric leakage accidents.
3.6When using a disinfection cabinet with an ozone generator, pay attention to whether the ozone generator is working properly. If you cannot hear the "squeaking" sound of high-voltage discharge or see the blue light of discharge, it indicates that the ozone generator may have a malfunction and should be repaired in a timely manner.
4Precautions
4.1The voltage withstand of the power socket should be greater than250V, with a capacity greater than6AThere is a good grounding wire to ensure safe use.
4.2There should be appropriate gaps between disinfectant items and they should not be stacked to avoid affecting the disinfection effect.
4.3Do not open the cabinet door during the disinfection process. Opening the cabinet door will stop the machine.
4.4The shelves of the disinfection cabinet have a certain strength, and it is not advisable to place too many items to avoid deformation of the shelves and affect the disinfection effect.