E-mail
Jenny.zhang@honesty-environ.com
-
Phone
13818328264
-
Address
11F, Building 1, Yaxin Technology Park, 399 Shengxia Road, Pudong New Area, Shanghai
Yiqian Environmental Protection Technology (Shanghai) Co., Ltd
Jenny.zhang@honesty-environ.com
13818328264
11F, Building 1, Yaxin Technology Park, 399 Shengxia Road, Pudong New Area, Shanghai
Every year, nearly 21000 Americans die because of radon pollution, which is six times more than the combined number of fire deaths and carbon monoxide deaths. Every household in the United States has some degree of radon pollution, and differences in weather, ventilation, season, and other factors can alter radon levels.
At present, the common equipment used for detecting radon gas is activated carbon canister, but activated carbon canister can only be used for short-term detection (a few days) and must be sent to the laboratory for analysis. This method is not only troublesome, but the radon content inside the carbon canister will also change over time. The emergence of Airthings has solved the existing dilemma. This device utilizes digital sensors and smart home technology to provide long-term detection services while also displaying real-time radon levels.
Corentium allows you to easily obtain radon concentration and calculate the average radon content for daily, weekly, or longer periods of time. Powered by three standard AAA batteries, it has strong portability and is suitable for testing in different places such as homes, laboratories, offices, schools, kindergartens, etc. It can eliminate hidden dangers in a timely manner and reduce radon concentration. It can also be used in professional fields to detect properties and the working status of radon elimination equipment.
| Technical Parameter | |
|
Sampling method |
Passive Radon Diffusion Chamber |
| test method | Alpha spectroscopy method |
| power supply | 3 AA alkaline batteries (LR06)~Battery life of 18 months |
| size | 14x 14x3 cm 140 x 140 x 30 mm |
| weight | 0.3kgs with battery included |
| operating ambient temperature |
4 to 40 °C < 85 % RH |
| detection range | 0 - 2700 pCi/L 0 - 100000 Bq/m³ |
|
Measurement uncertainty after 1 day Measurement uncertainty after 7 days |
Standard deviation<7%+0.12pCi/L Standard deviation<7%+5Bq/m ³ Standard deviation<5%+0.05pCi/L Standard deviation<5%+2 Bq/m ³ |
| Diffusion time constant | 25 Minutes |
| Internal storage capacity | 5 years, at a time resolution of 1 hour |
| sensor temperature resolution |
4 to 40 °C 0.2 °C ± 1 °F (typical), ± 2 °F (max) ± 0.5 °C (typical) , ± 1 °C (max) |
| humidity sensor resolution accuracy |
5% RH to 85% RH (non condensing) 0.5 % RH ± 4.5% (humidity range 20-80% RH) |
| Pressure sensor Range resolution |
50.0 kPa to 115.0 kPa 0.06 kPa ± 1 kPa |
| SunNuclear1028 | R 8000 | Avcat | Corentium pro | |
| NRPP certification | √ | √ | √ | √ |
| Bluetooth Device | — | — | — | √ |
| Applications and Reports | — | — | — | √ |
| redundancy | — | — | — | |
| Radon Chamber | 1 | 1 | 1 | |
| Battery life (days) | 4.5 | 5 | 5 | 550 days |
| Data storage (days) | — | 10 | 5 | 1825 days |
| Anti theft cable | — | — | — | √ |
| Volume (in) | 4.6*8.2*3.9 | 8*4.5*7 | 7*4*4 | |
| Weight (lbs) | 3 | 2.5 | 2.6 | 0.66 |