1、 Product Introduction:
DSA5000The portable composite gas detector is used for rapid detection of various gas concentrations and measurement of environmental temperature and humidity. If the alarm value is measured, an alarm will be issued.DSA5000use2.5Real time display on high-definition color screen, usingbrandSensors, the main detection principles include: electrochemistry, infrared, catalytic combustion, thermal conductivityPIDLight ions, etc.DSA5000Suitable for detecting gas concentration in pipelines, confined spaces, and atmospheric environments; Gas leakage and single gas concentration of various background gases such as nitrogen or oxygen. Detection types exceed500Other types.
2、 Product features:
●Can detect simultaneously1~5Gas species, units can be freely switched
Optional units:PPM、mg/m3、Vol%、LEL%、PPHM、ppb、mg/L.
●Built in pump suction measurement, integrated with water vapor and dust filters, fast response, supports long-distance sampling
Built in water vapor and dust filters prevent sensors and instruments from being damaged by water vapor and dust, and can be used in humidity and dust environments;
Sampling distance greater than10Rice, with special gas path design, can be directly detected; Negative pressure or positive pressure-0.5Gas weighing around 2 kilograms has no impact on the measurement results.
●Rich human-machine interface
2.5Inch high-definition color screen, displaying real-time concentration, alarm, time, temperature, humidity, storage, communication, battery level, charging status, concentration units
Information such as gas molecular formula and gas name; The menu interface uses high-definition simulation graphics to display the function names of each menu.
●Large capacity data storage function, supporting multiple storage methods
standard configuration10Ten thousand data storage capacity, large capacity can be customized; Support real-time storage, scheduled storage, or only storing alarm concentration data;
Support local viewing and deleting data, and can also be done throughUSBperhapsRS232The interface uploads data to the computer, and the upper computer software analyzes and stores the data
Storage and printing.
●Multiple communication interfaces and printing functions
Infrared communication interface (optional)USBInterfaceRS232Interface, optional external micro wireless infrared printer.
Print content: company name, gas name, date and time, environmental temperature and humidity, concentration data, test results (whether qualified).
●High temperature gas detection(Optional)
Optional # temperature sampling cooling filter handle or # temperature # humidity pretreatment system can detect800Smoke with high temperature. ##Temperature gas detection can be customized.
●Three display modes can be switched
Simultaneously display four gas concentrations, with large font circulating to display the concentration of a single channel gas, and real-time curve display.
●graphic display
Reflect the trend of gas concentration changes over a period of time in the form of a curve.
●Data recovery function
You can choose to partially or fully restore, eliminating the worries caused by misoperation.
● Can be set to display # large value, # small value, and average value
●standardUSBCharging, with charging protection function, supportsUSBHot Plug
Can be charged with a computer or power bank, compatible with mobile phone chargers; There are overcharging, overdischarging, overvoltage Short circuit and overheating protection;5Level power display;
The detector can work normally during charging.
●use5500mALarge capacity rechargeable polymer battery that can work continuously for a long time
●High precision temperature and humidity measurement (optional)
●Support real-time detection or scheduled detection
When not detecting, the pump can be turned off to extend the startup time.
●Multiple alarm methods, with multi-dimensional and three-dimensional indication of alarm status during alarm
Includes sound and light alarms, vibration alarms, and visual alarms on the display screen. The types of alarms include concentration alarm, undervoltage alarm, and fault alarm.
●Multiple alarm mode settings
Low alarm, high alarm, interval alarm, weighted average alarm.
● Misoperation recognition function
Automatic identification and prevention of concentration calibration errors can avoid adverse effects caused by human factors.
●Zero point automatic tracking, long-term use is not affected by zero drift
●Multi level calibration of target points to ensure measurement linearity and accuracy
●Chinese and English interface selectable
● Wide operating temperature:-40~+70℃, supports temperature compensation
●Log recording
Record calibration logs, maintenance logs, fault records, fault resolution measures, sensor life expiration reminder, and next concentration calibration time reminder function.
●Meet the requirements of intrinsic safety circuit design, anti-static, and anti electromagnetic interference
●Protection level up toIP66Waterproof, dustproof, explosion-proof, and shockproof
3、 Technical parameters:
Detect gas |
Composite gases (carbon monoxide CO, hydrogen sulfide H2S, oxygen O2, combustible gas Ex, carbon dioxide CO2), Optional: Can detect any 5 gas concentrations and temperature and humidity |
|||||||
detection range |
Refer to the attached table (call for consultation) |
|||||||
Resolution |
Refer to the attached table (call for consultation) |
|||||||
Detection Principle |
Electrochemical, catalytic combustion, infrared, thermal conductivity, PID photoionization, etc., depending on gas, range, on-site environment, and user requirements. |
|||||||
Sensor lifespan |
Electrochemical principle takes 2-3 years, oxygen can be used for 2 or 6 years, infrared principle takes 5-10 years, chemical combustion takes 3 years, and thermal conductivity takes 5 years. |
|||||||
detection |
Built in pump suction, flow rate500ml/minute |
|||||||
Display mode |
2.5cun320X240High definition color screen display, eightkey operation |
|||||||
check the accuracy |
≤± 2% F.S (higher precision can be customized) |
|||||||
Linearity |
≤±2% |
Repeatability |
≤±2% |
|||||
Alarm method |
Sound and light alarm, vibration alarm, visual alarm, sound and light alarm+vibrate+Visual alarm, turn off alarm |
|||||||
response time |
T90≤20second |
recovery time |
≤30second |
|||||
Working power supply |
DC3.6V |
|||||||
Battery capacity |
3.6VDC,5000mALarge capacity rechargeable polymer battery,Equipped with overcharge, overdischarge, overvoltage, overheating, and short circuit protection functions |
|||||||
Usage environment |
temperature-40℃~+70℃; Relative humidity ≤0-99%RH(Built in filter can be used in high humidity or high dust environments) |
|||||||
Sample gas temperature |
-40℃~+70℃ Optional high temperature sampling and cooling filter handle or high temperature and high humidity pretreatment system for detection 800℃ The concentration of flue gas |
|||||||
temperature measurement |
-40 ℃~+120 ℃ accuracy 0.5 ℃ |
Humidity measurement |
0-100% RH accuracy 3% RH |
|||||
Data Storage |
standard configuration10Ten thousand data capacity, customizable for larger capacity, supports local viewing or data export, free upper computer Communication software. The storage function is set to off by default and can be set to on. The storage time interval can be set arbitrarily |
|||||||
communication interface |
USB(Charging and Communication)RS232Infrared communication, automatic recognition |
|||||||
printer |
Optional, external micro wireless infrared thermal printer |
|||||||
Interface language |
Chinese or English can be set, default Chinese interface |
|||||||
Explosion proof type |
Intrinsically Safe |
Explosion proof grade |
Explosion proof Exd Ⅱ CT6 |
|||||
protection grade |
IP66Rain and water splashes, dust prevention |
|||||||
External dimensions |
180×78×33mm(L×W×H) |
Weight |
350g |
|||||
Standard accessory |
Instruction manual, certificate of conformity, warranty cardUSBCharger (including data cable), high-end aluminum alloy instrument box CD (upper computer communication software), crocodile clip, humidity and dust filter5individual |
|||||||
Optional accessories |
1.2 mScalable sampling handle (standard is1Meter, temperature and humidity measurement function, high temperature sampling and cooling filter handle High temperature and high humidity pretreatment system, multiple humidity and dust filters, hanging rope, external micro wireless infrared printer |
|||||||
Application scenarios |
All occasions requiring gas concentration detection, such as petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment, etc |
|||||||