Direct connected self-priming sewage pump

NegotiableUpdate on 03/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Direct coupled self-priming sewage pump is a direct coupled self-priming non clogging sewage pump that integrates self-priming and non clogging sewage discharge. It adopts an axial reflux external mixing type and, through the design of the pump body and impeller flow channel, can suction and discharge liquids containing large solid particles and long fiber impurities without the need for bottom valves and irrigation water like general self-priming water pumps. It is suitable for municipal sewage engineering, river pond aquaculture, light industry, papermaking, textile, food, and chemical industries
Product Details

Direct connected self-priming unobstructed sewage pumpIt integrates self-priming and non clogging sewage discharge, adopts axial reflux external mixing, and through the design of the pump body and impeller flow channel, it can suction and discharge liquids containing large solid particles and long fiber impurities without the need for bottom valves and irrigation water like general self-priming water pumps. It can be applied to municipal sewage engineering, river pond aquaculture, light industry, papermaking, textile, food, and chemical industries.

This pump has the characteristics of simple structure and easy use and maintenance, and has a broad application market and development prospects.
Scope of application of direct connected self-priming sewage pump
1. The ambient temperature is ≤ 50 ℃, the medium temperature is ≤ 80 ℃, and special requirements can be set at 200 ℃.
2. The pH value of the medium is 6-9 for cast iron and 2-13 for stainless steel.
3. Medium weight not exceeding 1240 kg/M3
4. The self-priming height cannot exceed the specified value of 4.5-5.5 meters, and the length of the suction pipe is 10 meters.
5. The suspended particle diameter is 60% of the pump diameter and the fiber length is 5 times the pump diameter.
Main performance parameters
model
Caliber (mm)
Traffic (m)3/h)
Head (m)
power
(kw)
speed
(r/min)
Self suction time
(min/5m)
efficiency
(%)
Net Positive Suction Head (NPSH)
(m)
Head (m)
Scope of application
weight
(kg)
Import
Export
25ZWL8-15
25
25
8
15
1.5
2900
3
45
2.0
10-15
100
25ZWL8-30
25
25
8
30
3
2900
3
45
2.0
24-30
120
32ZWL5-20
32
32
5
20
2.2
2900
3
45
2.5
15-20
100
32ZWL10-20
32
32
10
20
2.2
2900
3
45
2.5
15-20
100
32ZWL9-30
32
32
9
30
3
2900
3
48
2.5
24-30
120
40ZWL10-20
40
40
10
30
2.2
2900
3
45
2.5
15-20
100
40ZWL20-15
40
40
20
15
2.2
2900
3
45
2.5
10-18
100
40ZWL15-30
40
40
15
30
3
2900
3
48
2.5
24-30
120
50ZWL10-20
50
50
10
20
2.2
2900
3
45
2.5
15-20
100
50ZWL20-12
50
50
20
12
2.2
2900
3
45
2.5
10-18
100
50ZWL18-20
50
50
18
20
3
2900
3
45
2.5
18-22
120
50ZWL15-30
50
50
15
30
3
2900
3
48
2.5
24-30
120
50ZWL20-35
50
50
20
35
5.5
2900
3
48
2.5
25-35
150
50ZWL25-30
50
50
25
30
5.5
2900
3
48
2.5
25-30
150
50ZWL20-40
50
50
20
40
7.5
2900
3
48
2.5
32-40
200
50ZWL20-50
50
50
20
50
11
2900
3
48
2.5
40-50
250
65ZWL30-18
65
65
30
18
4
2900
3
45
2.5
13-18
160
65ZWL30-18
65
65
30
18
4
1450
3
45
2.5
13-18
200
65ZWL25-30
65
65
25
30
5.5
2900
3
50
3.0
25-30
200
65ZWL25-40
65
65
25
40
7.5
2900
3
50
3.0
32-40
200
65ZWL40-25
65
65
40
25
7.5
2900
3
50
3.0
20-25
200
65ZWL50-30
65
65
50
30
7.5
2900
3
50
3.0
25-30
200
65ZWL65-25
65
65
65
25
7.5
2900
3
52
3.0
20-25
200
65ZWL25-50
65
65
25
50
11
2900
3
53
3.0
40-50
280
80ZWL40-16
80
65
40
16
4
2900
3
50
3.0
13-18
180
80ZWL40-16
80
65
40
16
4
1450
3
50
3.0
13-18
200
80ZWL50-20
80
65
50
20
5.5
1450
3
50
3.0
13-20
240
80ZWL40-25
80
65
40
25
7.5
2900
2
50
3.0
20-25
200
80ZWL25-40
80
65
25
40
7.5
2900
2
50
3.0
32-40
200
80ZWL65-25
80
65
65
25
7.5
2900
2
52
3.0
20-25
240
80ZWL80-20
80
65
80
20
7.5
1450
3
52
3.0
10-20
240
80ZWL80-35
80
65
80
35
15
2900
3
45
3.0
30-35
285
80ZWL40-50
80
65
40
50
18.5
2900
2
50
3.0
40-50
293
80ZWL50-60
80
65
50
60
22
2900
3
55
3.0
48-60
326
100ZWL100-15
100
80
100
15
7.5
1450
3
50
4.0
10-15
300
100ZWL80-20
100
80
80
20
7.5
1450
3
53
4.0
10-20
300
100ZWL100-20
100
80
100
20
11
1450
3
53
4.0
12-20
340
100ZWL100-30
100
80
100
30
22
2900
2
53
4.0
25-30
510
100ZWL80-45
100
80
80
45
30
2900
2
55
4.0
35-45
560
100ZWL80-60
100
80
80
60
45
2900
2
53
4.0
50-60
585
125ZWL120-20
125
125
120
20
15
1450
2
55
4.0
8-15
500
150ZWL180-14
150
125
180
14
15
1450
3.5
60
5.0
8-14
500
150ZWL150-20
150
125
150
20
15
1450
3.5
60
5.0
8-15
500
150ZWL200-15
150
125
200
15
18.5
1450
3.5
60
5.0
8-15
550
150ZWL200-20
150
125
200
20
22
1450
3
60
5.0
10-20
570
150ZWL180-20
150
125
180
20
22
1450
3
60
5.0
10-20
570
150ZWL160-30
150
125
160
30
30
1450
3
65
5.0
20-30
680
150ZWL180-30
150
125
180
30
37
1450
3
65
5.0
20-30
700
150ZWL180-38
150
125
180
38
55
1450
3.5
45
5.0
30-38
800
150ZWL150-45
150
125
150
45
55
1450
3.5
45
5.0
35-45
800
200ZWL280-14
200
150
280
14
22
1450
3
65
5.0
8-14
820
200ZWL280-20
200
150
280
20
37
1450
3
62
5.0
10-20
910
200ZWL300-20
200
150
300
20
45
1450
3
59
5.0
15-25
948
200ZWL280-28
200
150
280
28
55
1450
3
55
4.8
18-28
1090
250ZWL420-20
250
200
420
20
55
1450
2.5
61
6.0
12-20
1150
300ZW800-14
300
250
800
14
55
1450
2.5
65
6.0
8-14
1400

Attention: If you need to inquire about other models of direct suction pumps, please contact our online customer service or our company's contact phone number

Special reminder
1. It is strictly prohibited to idle without liquid in the pump chamber
2. Check if the motor direction is correct, and it is strictly prohibited to reverse for a long time
3. Prohibit long-term operation of pumps under cavitation conditions
4. The inlet pipe must be strictly sealed to prevent water or air leakage
5. It is strictly prohibited for the motor to operate at overload for a long time under low field range and high flow conditions