Welcome Customer !

Membership

Help

Shanghai Changshen Pump Manufacturing Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products
Product Categories

Shanghai Changshen Pump Manufacturing Co., Ltd

  • E-mail

    ya5409@126.com

  • Phone

    13916511741

  • Address

    Shanghai Hutai Road

Contact Now

ZWL direct connected self-priming sewage pump

NegotiableUpdate on 03/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
ZWL direct coupled self-priming sewage pump ZWL direct coupled self-priming sewage pump ZWL direct coupled self-priming non clogging sewage pump adopts axial reflux external mixing type, and through the design of the pump body and impeller flow channel, it can be used as a general self-priming clean water pump without the need for bottom valves and irrigation water, and can also suck and discharge liquids containing large solid particles and long fiber impurities. It is suitable for impurity pumps in municipal sewage engineering, river pond breeding, light industry, papermaking, textile, food, chemical, electrical, fiber, pulp and mixed suspension and other chemical media
Product Details

ZWL direct connected self-priming sewage pump

The ZWL direct coupled self-priming non clogging sewage pump adopts an axial reflux external mixing type, and through the design of the pump body and impeller flow channel, it can be used as a general self-priming clean water pump without the need for bottom valves and irrigation water, and can also suck and discharge liquids containing large solid particles and long fiber impurities. It is suitable for impurity pumps in municipal sewage engineering, river pond aquaculture, light industry, papermaking, textile, food, chemical, electrical, fiber, pulp and mixed suspension chemical media.

Compared with other models of our company's products, this pump has the characteristics of simple structure, good self-priming performance, strong sewage discharge capacity, high efficiency and energy saving, easy use and maintenance, and has broad prospects for application and development.

Scope of Application
1. The ambient temperature is ≤ 50 ℃, the medium temperature is ≤ 80 ℃, and special requirements can be set at 200 ℃.
2. The pH value of the medium is 6-9 for cast iron and 2-13 for stainless steel.
3. Medium weight not exceeding 1240 kg/M3
4. The self-priming height cannot exceed the specified value of 4.5-5.5 meters, and the length of the suction pipe is 10 meters.
5. The suspended particle diameter is 60% of the pump diameter and the fiber length is 5 times the pump diameter.
Main performance parameters
model
Caliber (mm)
Traffic (m)3/h)
Head (m)
power
(kw)
speed
(r/min)
Self suction time
(min/5m)
efficiency
(%)
Net Positive Suction Head (NPSH)
(m)
Head (m)
Scope of application
weight
(kg)
Import
Export
25ZWL8-15
25
25
8
15
1.5
2900
3
45
2.0
10-15
100
25ZWL8-30
25
25
8
30
3
2900
3
45
2.0
24-30
120
32ZWL5-20
32
32
5
20
2.2
2900
3
45
2.5
15-20
100
32ZWL10-20
32
32
10
20
2.2
2900
3
45
2.5
15-20
100
32ZWL9-30
32
32
9
30
3
2900
3
48
2.5
24-30
120
40ZWL10-20
40
40
10
30
2.2
2900
3
45
2.5
15-20
100
40ZWL20-15
40
40
20
15
2.2
2900
3
45
2.5
10-18
100
40ZWL15-30
40
40
15
30
3
2900
3
48
2.5
24-30
120
50ZWL10-20
50
50
10
20
2.2
2900
3
45
2.5
15-20
100
50ZWL20-12
50
50
20
12
2.2
2900
3
45
2.5
10-18
100
50ZWL18-20
50
50
18
20
3
2900
3
45
2.5
18-22
120
50ZWL15-30
50
50
15
30
3
2900
3
48
2.5
24-30
120
50ZWL20-35
50
50
20
35
5.5
2900
3
48
2.5
25-35
150
50ZWL25-30
50
50
25
30
5.5
2900
3
48
2.5
25-30
150
50ZWL20-40
50
50
20
40
7.5
2900
3
48
2.5
32-40
200
50ZWL20-50
50
50
20
50
11
2900
3
48
2.5
40-50
250
65ZWL30-18
65
65
30
18
4
2900
3
45
2.5
13-18
160
65ZWL30-18
65
65
30
18
4
1450
3
45
2.5
13-18
200
65ZWL25-30
65
65
25
30
5.5
2900
3
50
3.0
25-30
200
65ZWL25-40
65
65
25
40
7.5
2900
3
50
3.0
32-40
200
65ZWL40-25
65
65
40
25
7.5
2900
3
50
3.0
20-25
200
65ZWL50-30
65
65
50
30
7.5
2900
3
50
3.0
25-30
200
65ZWL65-25
65
65
65
25
7.5
2900
3
52
3.0
20-25
200
65ZWL25-50
65
65
25
50
11
2900
3
53
3.0
40-50
280
80ZWL40-16
80
65
40
16
4
2900
3
50
3.0
13-18
180
80ZWL40-16
80
65
40
16
4
1450
3
50
3.0
13-18
200
80ZWL50-20
80
65
50
20
5.5
1450
3
50
3.0
13-20
240
80ZWL40-25
80
65
40
25
7.5
2900
2
50
3.0
20-25
200
80ZWL25-40
80
65
25
40
7.5
2900
2
50
3.0
32-40
200
80ZWL65-25
80
65
65
25
7.5
2900
2
52
3.0
20-25
240
80ZWL80-20
80
65
80
20
7.5
1450
3
52
3.0
10-20
240
80ZWL80-35
80
65
80
35
15
2900
3
45
3.0
30-35
285
80ZWL40-50
80
65
40
50
18.5
2900
2
50
3.0
40-50
293
80ZWL50-60
80
65
50
60
22
2900
3
55
3.0
48-60
326
100ZWL100-15
100
80
100
15
7.5
1450
3
50
4.0
10-15
300
100ZWL80-20
100
80
80
20
7.5
1450
3
53
4.0
10-20
300
100ZWL100-20
100
80
100
20
11
1450
3
53
4.0
12-20
340
100ZWL100-30
100
80
100
30
22
2900
2
53
4.0
25-30
510
100ZWL80-45
100
80
80
45
30
2900
2
55
4.0
35-45
560
100ZWL80-60
100
80
80
60
45
2900
2
53
4.0
50-60
585
125ZWL120-20
125
125
120
20
15
1450
2
55
4.0
8-15
500
150ZWL180-14
150
125
180
14
15
1450
3.5
60
5.0
8-14
500
150ZWL150-20
150
125
150
20
15
1450
3.5
60
5.0
8-15
500
150ZWL200-15
150
125
200
15
18.5
1450
3.5
60
5.0
8-15
550
150ZWL200-20
150
125
200
20
22
1450
3
60
5.0
10-20
570
150ZWL180-20
150
125
180
20
22
1450
3
60
5.0
10-20
570
150ZWL160-30
150
125
160
30
30
1450
3
65
5.0
20-30
680
150ZWL180-30
150
125
180
30
37
1450
3
65
5.0
20-30
700
150ZWL180-38
150
125
180
38
55
1450
3.5
45
5.0
30-38
800
150ZWL150-45
150
125
150
45
55
1450
3.5
45
5.0
35-45
800
200ZWL280-14
200
150
280
14
22
1450
3
65
5.0
8-14
820
200ZWL280-20
200
150
280
20
37
1450
3
62
5.0
10-20
910
200ZWL300-20
200
150
300
20
45
1450
3
59
5.0
15-25
948
200ZWL280-28
200
150
280
28
55
1450
3
55
4.8
18-28
1090
250ZWL420-20
250
200
420
20
55
1450
2.5
61
6.0
12-20
1150
300ZW800-14
300
250
800
14
55
1450
2.5
65
6.0
8-14
1400

Attention: If you need to inquire about other models of direct suction pumps, please contact our online customer service or our company's contact phone number

Installation, use and maintenance of ZWL type unobstructed self-priming sewage pump

Installation of ZWL type unobstructed self-priming sewage pump
The installation of ZWL type unobstructed self-priming sewage pump has a significant impact on the operation and service life of the pump, so it must be carefully carried out.
1. The installation height of the suction inlet of ZW type unobstructed self-priming sewage pump should not exceed 5 meters as much as possible, and special attention should be paid to the sealing of the suction pipeline to avoid air leakage and affect the self-priming capacity and normal operation of the pump.
2. The outlet of the ZW type unobstructed self-priming sewage pump should first be equipped with a vertical pipe (usually 0.4-1 meters) and a pressure gauge, and then the outlet flow control valve and other pipelines should be installed.
3. Reasonably configure the length and diameter of the pump inlet and outlet pipelines to reduce unnecessary head loss along the way. (Reference can be made to the straight pipe friction loss summary table for estimation)
4. When transporting over long distances, larger pipe diameters should be selected. The pump pipeline should have its own support, and the pump body itself is not allowed to bear the load of the pipeline.
5. If a check valve is installed in the discharge pipeline, it should be installed outside the outlet flow control valve.

The use of ZWL type unobstructed self-priming sewage pump
1. Before use, check whether the rotation direction of the pump is correct and whether it rotates flexibly.
2. Unscrew the filling plug above the pump body, fill the reservoir, and then tighten the plug. In the future, there will be no need to refill the reservoir when starting up. The pump should not be started and operated when there is insufficient liquid storage, otherwise the pump cannot work properly and the mechanical seal may be damaged.
3. When starting up, the outlet flow control valve should be opened first to facilitate the discharge of gas during the self-priming process. After starting, adjust the opening of the outlet flow control valve to ensure that the pressure gauge reading is within the specified range (various pump type pressure control range tables), avoiding the pump from working within the lower limit of the specified range, to prevent motor overload and burnout caused by excessive shaft power or cavitation caused by excessive flow, affecting the normal operation of the pump and causing strong vibration and noise.
4. During operation, the temperature rise of the pump and motor should be checked regularly. If noise or other abnormal sounds are found, the machine should be stopped for inspection and troubleshooting before resuming operation.
5. When shutting down, the outlet flow control valve should be closed first before shutting down to avoid insufficient liquid storage in the pump due to siphon effect.
6. Regularly refuel and maintain the pump. If it is not used for a long time, the pump should be disassembled, cleaned, and oiled, and stored properly.

Special reminder
1. It is strictly prohibited to idle without liquid in the pump chamber
2. Check if the motor direction is correct, and it is strictly prohibited to reverse for a long time
3. Prohibit long-term operation of pumps under cavitation conditions
4. The inlet pipe must be strictly sealed to prevent water or air leakage
5. It is strictly prohibited for the motor to operate at overload for a long time under low field range and high flow conditions