EC-4110-ICONElectromagnetic concentration meter
◼ principle
Inductive electrode
Intelligent Conductivity Transmitter…EC-4110I(ICON)
Inductive electrodes are composed of two wound metal ring coils
Wire wound metal toroids wrapped in corrosion-resistant material
Electrodes composed of corroded materials
Immerse the inductive electrode into the electrolyte liquid, controller
Release voltage to the driving coil and the liquid around the coil
Also senses voltage and drives ion current to generate
By measuring the ion current generated through the receiving coil, it is possible to
After conversion, the conductivity is obtained
The electrode itself will not directly contact the sample and can be used in solutions that corrode metal electrodes
✓ Can be used in solutions containing high concentrations of suspended solids
As long as the annular area is not altered by the sample, the reading will be accurate
✓ Suitable for measuring high conductivity solutions, cannot be used for measuring low conductivity solutions
◼EC-4110-ICONElectromagnetic concentration meterApp Market
Chemical industry: sulfuric acid, chlor alkali plants, sodium chloride, sodium hydroxide, hydrochloric acid, phosphoric acid, nitric acid, detergents, wastewater, moisture detection containing HF, washing equipment
Semiconductor: concentration monitoring, cooling water leakage detection, washing equipment, continuous acid washing, electroplating solution monitoring/control, wafer cleaning process monitoring, etching solution concentration monitoring;
Environmental water quality: wastewater monitoring, salinity
Food: Automatic cleaning application, rinse water
Pharmaceutical: pharmaceutical water, filtration dissolution process, ion exchange, purification and separation process
Other: boiler water system, flue gas scrubber
Technical Specifications
model |
EC-4110I |
EC-4110ICON |
|||
test project |
Conductivity/TDS/Salinity/Temp/Concentration |
||||
|
test scope |
conductivity |
000.0 μS/cm~2000 mS/cm gearSelect or automatically switch |
|||
salinity |
0.0ppt~70.0ppt |
||||
TDS |
0ppm~19999ppm; 0.00~199.9ppt |
||||
temperature |
PTC1000:-30.0~200.0˚C, NTC30K:-30.0~130.0˚C |
||||
|
concentration |
NaCl_28%:0-28 % HCl_18%:0-18 % HCl_39%:22-39 % HNO3_30%:0-30 % HNO3_96%:35-96 % NaOH_24%:0-24 % |
NaOH_50%: 15-50 % H2SO4_37%:0-37 % H2SO4_88%:28-88 % H2SO4_99%:89-99 % H3PO4_35%:0-35 % Custom concentration table(9x9 matrix) |
|||
resolution |
concentration |
- |
0.01% |
||
conductivity |
0.1μS/cm、0.001/0.01/0.1/1 mS/cm |
||||
temperature |
0.1˚C |
||||
accuracy |
conductivity |
≥1mS/cm ±1% (±1 Digit) <1mS/cm ±10μS/cm |
|||
temperature |
±0.2˚C (±1 Digit) Equipped with temperature error correction function |
||||
temperature compensation |
NTC30K / PT1K Automatic temperature compensation or manual temperature compensation |
||||
Correction mode |
(1) Electrode constant correction (2) Calibration of conductivity standard solution (3) Zero point correction |
||||
Working environment temperature |
0~50°C |
||||
Storage environment temperature |
-20~70°C |
||||
display mode |
General mode, real-time graphic mode, and trace graphic recording mode |
||||
Electrode coefficient |
0.008~9.9999 cm-1 adjustable |
||||
Temperature compensation coefficient |
Linear temperature compensation coefficient(0.00%~40.00%), non-linear temperature compensation, no compensation |
||||
current output |
isolated0/4~20mA Corresponding specific resistance can be set/Conductivity measurementRange, load 500Ω |
||||
Event log book |
provide 50 Group important events and error diagnosis records |
||||
RS485 interface |
RS485(Modbus RTU or ASCII) |
||||
control |
Contact output |
RELAY ON/OFF Contact point,240VAC 0.5A Max.(suggestion) |
|||
setting |
Two independent groups can be set high/Control point of low point (HI/LO) |
||||
Cleaning settings |
Contact output,ON 0~99 divide 59 second/ OFF 0~999 hour 59 divide |
||||
protection level |
IP65 |
||||
power supply |
100V~240VAC±10%, 7W Max., 50/60Hz |
||||
Local size |
96mm ×96mm ×132mm (H×W×D) |
||||
Hole size |
93 mm × 93 mm (H×W) |
||||
weight |
0.5 kg |
||||