Ethernet port sound noise sensorparameter
Product Model |
JHM-NS02 |
Specifications |
80mmX25mm |
accuracy |
+/-1.5dB (2Khz80dB point correction) |
Conversion accuracy |
0.1dB |
output mode |
RS232 interface ASIIC code output |
A-weighted measurement range |
30dB to 120dB (automatic shifting) |
frequency response |
35 Hz to 20KHz |
Frequency weighting characteristic |
A weighted characteristic |
Microphone manufacturer |
Toshiba capacitive (windproof outer cover) |
Dynamic characteristic time weighting |
FAST |
Working and storage temperature |
-10 ----- 60℃ |
Working and storage humidity |
10 ----- 90RH% |
Power standard |
DC9V-DC12V (ripple<0.5%) current 30mA |
manufacturer |
Beijing Jinghaiming Electronic Technology Research Institute |
Ethernet port sound noise sensorInstructions:
Power supply: DC12V, 10M speed IP/UDP communication, supports ping.exe command response.
Port: The port and IP can be set by entering commands through the serial port. RS232 communication: communication mode 9600, n, 8,1, ASIC characters for information, enter key 'Enter' corresponds to hexadecimal 0x0d+0x0a.
--------------------------------------------------------------------------------------
Is the device's IP: CM+IP=? (Enter)
Example: The device answers CM+IP=192.168.0.1 (Enter)
------------------------------------------------------------
Set IP to 192.160.4.5, serial input CM+IP=192.160.4.5 (Enter)
Query the port of this device: CM+PORT=? (Enter)
Example: The device answers CM+PORT=8253 (Enter)
Reset port to 8255, enter the command CM+PORT=8255 (Enter)
----------------------------------------------------------------------------------------------
Other online devices within the local area network obtain the noise measurement value of this device:
Port, IP, and device match, transmitting CM+NS02=? (Enetr) command, the device sends back CM+NS02=xxx. x (Enetr) message, returning the current noise value xxx. x.