Overview
The self-priming height of a self-priming pump is related to factors such as the sealing gap in front of the impeller, the pump speed, and the liquid level in the separation chamber. The smaller the sealing gap in front of the impeller, the greater the self-priming height, generally taken as 0.3~0.5 millimeters. FMZ type horizontal self-priming pump manufacturer
Product Details

FMZ type horizontal self-priming pump manufacturer

Start, stop, disassemble, and assemble
1. Start up
A: Turn on the cooling water and rotate the coupling by hand, there should be no rubbing phenomenon (no need to refill the fluid when starting in the future)
B 、 Start the motor and loosen the filling hole cover without tightening it to facilitate exhaust. The valve on the outlet pipe should also be slightly opened at the same time. After the water discharge is normal, tighten the filling hole cover and slowly adjust the valve on the outlet pipe to the desired working condition. It usually takes 2-10 minutes to start and discharge water.
C 、 The temperature rise of the pump bearing and motor should be checked regularly, and the temperature rise of the bearing should not exceed 75 degrees.
D 、 Pay attention to the absence of noise during pump operation. If any abnormal situation occurs, stop the pump immediately for inspection.
2. Parking
A 、 Slowly close the outlet pipeline valve and various instruments.
B 、 Cut off the power supply.
C 、 After stabilizing, turn off the cooling water.
3. Dismantling
When the pump needs maintenance due to abnormal conditions, it should be disassembled in order.
A: Remove the oil drain bolt from the bracket and drain all the lubricating oil inside the bracket.
B: Remove the nut from the bracket and pump body, take off the pump body, turn left to unscrew the impeller nut, and take out the impeller and key.
C: Remove the pump cover, coaxial sleeve, mechanical seal, etc. from the pump shaft.
D: Unscrew the bolts on the sealing cover, remove the sealing cover, mechanical seal dynamic ring, and shaft sleeve. Unscrew the connecting bolts between the sealing box and the pump cover, and remove the mechanical seal static ring.
E: Remove the bearing end caps from both ends of the bracket, take out the pump shaft and bearings, and then remove the bearings from the pump shaft.
F: If you encounter difficulties during disassembly, please contact our company.
4. Assembly
The assembly sequence is opposite to the disassembly sequence.
5、 Performance Range
Traffic Q: 3.2-280m 3/good
Head H: 12-90m
Cavitation allowance: 3.5-5.5m
Power consumption: 1.5-90KW

FMZ type horizontal self-priming pump manufacturer