An electromagnetic flowmeter consists of two parts: a sensor and a converter. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media. In addition to measuring the volumetric flow rate of general conductive liquids, it can also be used to measure the volumetric flow rate of strong corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud, slurry, and pulp. Widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management, water conservancy construction, river dredging and other fields for flow measurement.
Product Details

Flow meters used in the feed industryInstallation of electromagnetic flowmeterElectromagnetic flowmeter debugging-Huai'an Wanfeng Measurement and Control Technology Co., Ltd. puts quality first, Integrity based, excellent service. We provide product consultation, selection guidance, pricing and other services to our customers. We welcome customers to place orders! : mobile phone/V信:

Electromagnetic FlowmeterIt consists of two parts: sensors and converters. It works based on Faraday's law of electromagnetic induction and is used to measure the volumetric flow rate of conductive liquids with a conductivity greater than 5 μ S/cm. It is an inductive instrument for measuring the volumetric flow rate of conductive media. In addition to measuring the volumetric flow rate of general conductive liquids, it can also be used to measure the volumetric flow rate of strong corrosive liquids such as strong acids and alkalis, as well as homogeneous liquid-solid two-phase suspensions such as mud, slurry, and pulp. Widely used in industrial sectors such as petroleum, chemical, metallurgical, textile, papermaking, environmental protection, food, as well as municipal management, water conservancy construction, river dredging and other fields for flow measurement.

Electromagnetic FlowmeterTechnical difference:

Nominal diameter (mm)

(Special specifications can be customized)

Pipeline type PTFE lining: DN10~DN600

Pipeline rubber lining: DN40~DN2200

flow direction

Positive, negative, net traffic

turndown ratio

150:1

repeatability error

± 0.1% of the measured value

accuracy class

Pipeline type: 0.5 level, 1.0 level

Temperature of the measured medium

Ordinary rubber lining: -20 to+60 ℃

High temperature rubber lining: -20 to+90 ℃

PTFE lining: -30 to+100 ℃

High temperature PTFE lining: -20 to+180 ℃

Rated working pressure
(High voltage can be customized)

DN10-DN150:≤1.6MPa

DN200-DN350:≤1.0MPa

DN400-DN1000:≤0.6MPa

DN450-DN2200:≤0.25MPa

Flow velocity range

0.1-15m/s

Conductivity range

The conductivity of the measured fluid is ≥ 5 μ s/cm

signal output

4-20mA (load resistance 0-750 Ω), pulse/frequency, control level

communication output

RS485, MODBUS protocol, HART protocol

power supply

AC220V or DC24V

Require the length of the straight pipe section

Upstream ≥ 5DN, downstream ≥ 2DN

connection method

The flowmeter and piping are connected by flanges, in accordance with the national standard GB/T9115.1-2000

Explosion-proof rating

ExdeiallBT4-T6

Protection level

IP65, Specially customized up to IP68

ambient temperature

-25~+60℃

relative temperature

5%~95%

Total power consumption

Less than 20W

Flow meters used in the feed industry:

model

code

Instructions

WFLDE

Electromagnetic Flowmeter

path

□□□

10-2200mm

structural form

S

integrated type

L

Split type

electrode material

M

stainless steel

T

Ti (titanium)

D

Ta(钽)

H

Hastelloy

P

Pt platinum

N

Ni nickel

output method

0

No output

1

4-20mA/1-5KHz

2

4-20mA

Lining material

X

rubber

F

Polytetrafluoroethylene

P

polyethylene

J

polyurethane rubber

display in situ

0

No on-site display

1

display in situ

contact method

0

No communication

1

RS485

2

RS232

3

Modbus

4

Hart

ground loop

0

No grounding ring

1

There is a grounding ring

2

There is a grounding electrode

Maximum traffic limit

(n)

Upper limit flow rate (range) m3/h

Determination of instrument diameter:

Caliber mm

Flow range m3/h

Caliber mm

Flow range m3/h

φ15

0.06~6.36

φ450

57.23~5722.65

φ20

0.11~11.3

φ500

70.65~7065.00

φ25

0.18~17.66

φ600

101.74~10173.6

φ40

0.45~45.22

φ700

138.47~13847.4

φ50

0.71~70.65

φ800

180.86~18086.4

φ65

1.19~119.4

φ900

228.91~22890.6

φ80

1.81~180.86

φ1000

406.94~40694.4

φ100

2.83~282.60

φ1200

553.90~55389.6

φ150

6.36~635.85

φ1600

723.46~72345.6

φ200

11.3~1130.4

φ1800

915.62~91562.4

φ250

17.66~176.25.

φ2000

1130.4~113040.00

φ300

25.43~2543.40

φ2200

1367.78~136778.4

φ350

34.62~3461.85

φ2400

1627.78~162777.6

φ400

45.22~4521.6

φ2600

1910.38~191037.6

DN15-DN150 integrated type and sensor outline drawing

Dimensions and weight

Nominal Diameter
DN
L W H Reference weight kg
integrated type sensor
15 200 140 174 10 7
20 200 140 174 12 9
25 200 140 174 14 11
40 200 176 210 16 13
50 200 176 210 17 14
65 200 214 250 25 22
80 200 214 250 29 26
100 250 230 312 31 28
150 300 230 370 41 38

Flange size (standard: GB/T9119)

Nominal Diameter
DN
Pressure 1.6MPa Pressure 4.0MPa
D d1 d0 n b D d1 d0 n b
15 95 65 14 4 16 95 65 14 4 16
20 105 75 14 4 18 105 75 14 4 18
25 110 85 14 4 18 110 85 14 4 18
40 150 110 18 4 20 150 110 18 4 20
50 165 125 18 4 20 165 125 18 4 20
65 185 145 18 4 20 185 145 18 8 22
80 200 160 18 8 22 200 160 18 8 22
100 220 180 18 8 22 235 190 22 8 26
150 285 240 22 8 24 300 250 26 8 28
DN200~DN600 Integrated Type and Sensor Outline Drawing Dimensions and weight

Nominal Diameter
DN
L H
φ~
Reference weight
200 350 310 45
250 450 358 50
300 500 410 60
350 550 465 145
400 600 515 180
450 600 564 215
500 600 614 245
600 600 722 335
Flange size (standard: GB/T9119)
Nominal Diameter
DN
Pressure 1.6MPa Pressure 4.0MPa
D d1 d0 n b D d1 d0 n b
200 340 295 22 12 26 340 295 22 8 24
250 405 355 26 12 28 395 350 22 12 26
300 460 410 26 12 32 445 400 22 12 28
350 520 470 26 16 35 550 460 22 16 30
400 580 525 30 16 38 565 515 26 16 32
450 64, 0 585 30 20 42 615 565 26 20 35
500 715 650 33 20 46 670 620 26 20 38
600 840 770 36 20 52 780 725 30 20 42