Fluorescence dissolved oxygen analyzer

NegotiableUpdate on 05/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The DC-5320RS fluorescence method dissolved oxygen analyzer is multifunctional and covers the measurement of dissolved oxygen and gases. It has IP65 dust and water resistance, 4-20mA or RS-485 signal output, and can achieve performance in harsh application environments

Product Details

DC-5320RSFluorescence dissolved oxygen analyzer

⚫ versatility

DC-5320-RS covers the measurement of dissolved oxygen and gases

IP65 dustproof and waterproof

4-20mA or RS-485 signal output

Performance achievable in harsh application environments

⚫ Intuitive operation

Visual form operation is easy to learn

⚫ Real time monitoring and management

Capable of real-time monitoring of samples and providing status alerts, reducing management risks

⚫ Suitable for German PreSens brand optical dissolved oxygen electrode

OXYBase is suitable for wastewater/environmental measurement/aquaculture

OXYPro Biopharmaceutical/Food and Beverage Applications

Specially designed controller for PreSens optical dissolved oxygen electrode

DC-5320RSFluorescence dissolved oxygen analyzer

• Can measure the dissolved oxygen content in the solution

• Can measure the oxygen content in the air

荧光法溶氧测定仪

◼ Principle of Optical Dissolved Oxygen Measurement

OXYBase or OXYPro optical dissolved oxygen electrode consists of a probe body and an integrated optical oxygen sensor

Electronic and optical components (LEDs, photodiodes, and optical filters) are integrated into stainless steel tubes

The oxygen sensor in the optical oxygen sensor receives light pulses from the signal LED. Then, the sensor undergoes optical filtering, detection, and is transferred to the electronic board for signal processing.

◼ Consumables: Optical oxygen sensors O-ring

O-ring is replaced annually to maintain sealing (Order no. 200001368)

DC-5320RSFluorescence dissolved oxygen analyzerSpecifications

model

DC-5320-RS

test project

%Sat / %O2 / ppm / mg/L / ppb / μg/L/ Temp

test scope

%Sat

0~600% (according toelectrodedetermined by)


%O2

0~120% (according toelectrodedetermined by)


mg/LTheppm

0~60.00 mg/L (ppm)(according toelectrodedetermined by)


μg/LTheppb

0~99900μg/L (ppb) (according toelectrodedetermined by)


temperature

0~140°C (according toelectrodedetermined by)

resolution

%Sat

0.1%


%O2

0.01%/0.001%


mg/LTheppm

0.01 mg/L / 0.001 mg/L(0.01ppm / 0.001ppm)


μg/LTheppb

0.1μg/L(ppb)


temperature

0.1°C

accuracy

%Sat

according toElectrode dependent


%O2



mg/LTheppm



μg/LTheppb



temperature


temperature compensation

Automatic temperature compensation


Manual temperature compensation

Salinity compensation

00~45pptManual compensation

pressure compensation

Compensation scope0.500~2.500bar7.25~36.25psiThe500 ~ 2500 mmHgmanual adjustment