Full heat exchange fresh air ventilator

NegotiableUpdate on 02/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The total heat exchange fresh air ventilator is a type of fresh air system, which is divided into one-way flow fresh air, two-way flow fresh air, and total heat exchanger fresh air system. It has many advantages of fresh air system and is a comfortable and energy-saving fresh air system.
Product Details

Full heat exchange fresh air ventilatorIn the professional terminology of fresh air, it is called a total heat exchanger. Compared with other ventilation equipment, its biggest feature is the presence of a total heat exchange core, which can exchange heat with air and send it indoors or outdoors to save energy. In summer, the total heat exchange core installed in the system can reduce the temperature of the outdoor intake air and enter the room in a way that is closer to room temperature; In winter, the low temperature of outdoor air intake can be raised to enter the room at a temperature higher than that of outdoor air, thereby preventing indoor temperature loss and reducing energy consumption.

1、 Selection steps for fresh air system

1. Select different installation types of fresh air ventilators based on the structural characteristics of the building

2. Determine the appropriate fresh air volume based on room usage, area, and number of internal personnel

3. Select the specifications and quantity of equipment based on the determined fresh air volume, and determine the required fresh air indicators for civil comfort air conditioning rooms

2、 New air indicators required for comfortable air-conditioned rooms for civilian use

Note: When determining the required fresh air volume for a room, it should be considered based on the size of the room and the overall number of indoor occupants. According to the recommended data in the table above, calculate the fresh air volume value based on the required fresh air volume per person and the number of room fresh air changes. Take the larger of the two as the basis for equipment selection.

2. For special industries such as hospitals (operating rooms, special wards), laboratories, and industrial workshops, the required fresh air volume should be determined according to the relevant design specifications of the industry.

3、 Installation and maintenance instructions

1. When installing with a suspended ceiling, maintenance space must be reserved according to the size of the unit;

2. The air duct leading to the outside should maintain a slope to prevent rainwater from flowing back;

3. The core of the heat exchanger should be cleaned once a year by using a vacuum cleaner to remove surface dust;

4. The fresh air and exhaust filters should be cleaned with clean water and detergent after six months of operation, and the cleaning cycle should be shortened in dusty areas;

5. When the unit is used in cold regions, insulation measures should be taken at the fresh air inlet and air duct of the unit;

6. The unit should generally be installed indoors. If installed outdoors, shading and rain protection facilities should be installed, and all outdoor air ducts must be insulated.