HUMO-206 in-situ flue gas humidity&oxygen analyzer

NegotiableUpdate on 03/11
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
HUMO-206 flue gas humidity and oxygen analyzer adopts the second-generation solid-state electrolyte humidity and oxygen measurement technology independently developed by Yingchuang Environment, which is used for real-time monitoring of humidity and oxygen in high-temperature corrosive flue gas
Product Details

HUMO-206 flue gas humidity&oxygen analyzer is independently developed by Yingchuang EnvironmentThe second-generation solid-state electrolyte humidity and oxygen measurement technology is used for real-time monitoring of humidity and oxygen in high-temperature corrosive flue gas.

The product featuresHigh measurement accuracy, strong corrosion resistance, stable and reliable performance.Solved the problem of garbage incinerationUnder harsh working conditionsHumidity oxygenPoor corrosion resistance of the analyzeruseShort lifespan, etcIndustry challenges.

satisfyTechnical requirements for online monitoring of flue gas humidity and oxygen in HJ75-2017 and HJ76-2017 standards.


1. Can be used for a long time in high-temperature flue gas environments

2. Meet the requirements of integrated online monitoring of humidity and oxygen

3. Adopting self-developed technologySecond generation solid-state electrolyte oxygen measurement technology

4. sceneservice lifeLonger,corrosion-resistantperformancestronger

5. IP65 protection level, suitable for outdoor use in harsh weather conditions

6. Easy to operate, long service life, and easy maintenance

7. Volume percentage output, meeting environmental testing requirements

8. Humidity and oxygen can be calibrated on site to ensure measurement accuracy

Measurement principle: Dry wet oxygen principle

Detection range: H2O 0-40VOL%

O2 0-25VOL%

Measurement accuracy: H2O ± 1.5% F.S

O2 ±1.0% F.S.

Repeatability: ± 1.0% F.S

Response time: T90<20S

Sampling method: Insertion type

Installation method: Standard DN65 flange, other specifications can be customized

Probe length: standard length 0.8m, other specifications can be customized

Smoke temperature: 0-250 ℃

Display mode: LCD screen display, inside the instrument panel

Power supply: 220VAC ± 10% 50HZ, 30W

Interface: 4-20mA, 0-5V, 0-10V optional