JC-FI32 Direct Sampling Automotive Exhaust Analyzer

JC-FI32 Direct Sampling Automotive Exhaust Analyzer
Main technical parameters
JC-FI32 Exhaust gas analysers |
|
measurement range |
CO:0~10.0 10-2(%) CO2:0~20.0 10-2(%) HC:0~10000 10-6(ppm) O2:0~25.0 10-2(%) NO:0~5000 10-6(ppm) |
Repetitive Wu poor |
≤±2% |
zero drift |
CO:±0.06 10-2(%)/4h CO2:±0.5 10-2(%)/4h HC:±30 10-6(ppm)/4h O2:±0.5 10-2(%)/4h NO:±30 10-6(ppm)/4h |
Distance drift |
Not exceeding the allowable difference of the displayed value wu(4hour) |
indication error |
CO:±5%(Relative Wu difference,0~10%) CO2:±5%(Relative)wuPoor,0~20%) HC:±5%(Relative)wuPoor,0~4000ppm)±10%(Relative error,4001~10000ppm) O2:±5%(Relative)wuPoor,0~25%) NO:±4%(Relative)wuPoor,0~5000ppm) |
environmental conditions |
temperature0℃~40℃ Humidity: ≤80% Atmospheric pressure:60~105KPa power supplyAC 220V±10%;50Hz±1Hz |
warm-up time |
10min |
heavy quantity |
9.8Kg |
body accumulate |
420*320*250(mm) |
Sampling method |
Exhaust gas: direct sampling, sampling tube length5mLength of sampling probe900mm; |
display mode |
LCDLarge screen LCD display |
Main functions |
1Compliant withGB/T 18285-2005Requirements for dual idle detection method of emissions pollutants from spark ignition engines and spark ignition engine vehicles in China 2The main components of the product are all imported accessories that meet the metrological verification regulationsJJG-688The Level I accuracy requirement specified in the document 3Used for measuring automobile exhaust gasesHCTheCOTheCO2TheO2TheNOXThe concentration 4TheLCDLCD display screen, full Chinese operation menu display 5Equipped with idle and dual idle testing functions 6High precision detection, automatic prompt for zero adjustment 7Automatically calculate and display the excess air coefficient λ 8Built in clock module, capable of displaying time and switching between Chinese and English 9Equipped withRS-232Interface, capable of communicating with computers through networking 10Built in thermal printer, quickly print the current measurement results and instrument stored result information 11The license plate input function can be stored500Group data, automatic recording, printing of test results 12Multiple fuel options including natural gas, liquefied gas, ethanol, etc |