Welcome Customer !

Membership

Help

Sifang Optoelectronics (Wuhan) Instrument Co., Ltd
Custom manufacturer

Main Products:

cep-online>Products

Sifang Optoelectronics (Wuhan) Instrument Co., Ltd

  • E-mail

    cubic-ry56@gasanalyzer.com.cn

  • Phone

    18627990650

  • Address

    No. 6 Fenghuangyuan Middle Road, Fenghuangyuan Industrial Park, Donghu New Technology Development Zone, Wuhan, Hubei Province

Contact Now

Laser ammonia analyzer

NegotiableUpdate on 04/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The NH3-CEMS GasTDL-3001 laser ammonia analyzer uses tunable semiconductor laser absorption spectroscopy (TDLAS) technology, which is suitable for online monitoring of ammonia concentration at the outlet of denitrification processes. The system adopts a close range extraction method, with the measurement unit installed outside the flue wall. The gas path in contact with the sample gas is heated at high temperature throughout the entire process to avoid ammonia adsorption and loss, ensuring the authenticity of the sample gas. It can accurately reflect changes in ammonia escape in real time and provide reliable data support for environmental monitoring.
Product Details

Product Name:Laser ammonia analyzer

Product model: GasTDL-3001


Product Overview

Laser ammonia analyzerGasTDL-3001 adopts tunable semiconductor laser absorption spectroscopy (TDLAS) technology, which is suitable for online monitoring of ammonia concentration at the outlet of denitrification processes. The system adopts a close range extraction method, with the measurement unit installed outside the flue wall. The gas path in contact with the sample gas is heated at high temperature throughout the entire process to avoid ammonia adsorption and loss, ensuring the authenticity of the sample gas. It can accurately reflect changes in ammonia escape in real time and provide reliable data support for environmental monitoring.


Product Features

(1) Using TDLAS technology, the measured gas is not affected by background gas interference

(2) Ultra low range measurement, using multiple reflection chambers, with a low detection limit

(3) The system adopts a full calibration method to improve the accuracy of measurement results

(4) The gas flow path is heated at high temperature throughout, and low adsorption materials and treatment processes are used to effectively avoid NH3Condensation loss

(5) Extractive measurement, unaffected by dust, temperature, and pressure fluctuations in the flue

(6) Equipped with full calibration function


Technical Specifications


performance metrics
Measure components NH₃
Measuring principle TDLAS
range Adjustable from 0~10~100ppm
precision ±1%F.S.
repetitiveness ±1%
resolution 0.01ppm
Zui low detection limit ±1%F.S.
Protection level IP65 or above
response time T90≤30s
working conditions
ambient temperature -30~60℃
ambient humidity 5~85%RH
working power supply 220VAC,50Hz,800W
Blow off gas source 0.4~0.8MPa compressed air
communication 1 channel RS-232, 1 channel RS-485
output mode 4-channel 4-20mA output, 8-channel relay output